SU-FF-T-62: Dosimetric Evaluation of An Internal Shielding Used with a HDR Skin Applicator
2009
Purpose: The Valencia HDR skin applicators are accessories of the microSelectron HDR afterloading system (Nucletron) cup shaped to limit the dose to the irradiation area. Applicators sizes are: diameter 2 and 3 cm. The typical prescription depth is 3 mm. This work aims to evaluate the backscatter and electron contamination of an internal shielding used to reduce the dose to the ocular globe when the lesion is located at the eyelid. Monte Carlo(MC) and experimental methods have been used. Method and Materials: The geometry has been: the Valencia applicator (2 cm diameter) on the surface of a solid polystyrene slab phantom; inside, a 2 mm lead slab located at 3 mm depth. MC simulation charact…
Characterisation of two new radiochromic gel dosimeters TruView™ and ClearView™ in combination with the vista™ optical CT scanner: A feasibility study
2018
This study aims at characterising the properties of TruView™ and ClearView™ two new gel dosimeters (Modus Medical Devices Inc.) and at studying the feasibility of relative dosimetry using these dosimeters and the Vista™ Optical CT scanner to accurately evaluate dose.In this work, we investigated key dosimetric aspects (dose response, energy and dose rate dependence) and stability of these radiochromic gels initiated in preliminary works (Huet et al., 2017; Colnot et al., 2017) using spectrophotometric measurements. Moreover, by mean of optical CT scanning (Vista™), their performances to measure relative depth dose (PDD) and cross profiles were analysed.TruView™ and ClearView™ present a line…
EP-1590: Shielding design and fetal dose evaluation of a breast cancer pregnant patient undergoing HDR Ir-192 brachytherapy
2015
Phenol compounds for Electron Spin Resonance dosimetry of gamma and neutron beams
2014
Sviluppo e Applicazioni di nuovi materiali per la dosimetria delle radiazioni ionizzanti
The Research Activities carried out during the Three-year International PhD Course in Applied Physics of the candidate Salvatore Gallo had two main topics related to dosimetry of ionizing radiations (IR): the analysis of 3D gel dosimeters and the analysis of solid state dosimeters through electron spin resonance. Both these activities are focused on a careful study of new materials for the IR Dosimetry, both in terms of physical characterization of these new materials and of the optimization of readout methods for dosimetric measurements. The study performed through various techniques such as UV-Vis absorption spectroscopy, NMR Relaxometry, Magnetic Resonance Imaging (MRI) and Electron Spin…
Characterization of phenolic pellets for ESR dosimetry in photon beam radiotherapy.
2017
We report a study of the dosimetric features of phenolic compounds for applications in radiation therapy dosimetry of clinical photon beams by using ESR spectroscopy. After the optimization of the ESR readout parameters, basic dosimetric properties (such as intra-batch reproducibility, dose-response, sensitivity, linearity, dose rate dependence, tissue-equivalence and signal stability) of laboratory-made phenolic dosimeters in form of pellets were investigated. Furthermore, these dosimeters were tested for measuring the depth dose profile of a 6 MV clinical photon beam. The results reported show that these dosimeters are promising materials for ESR dosimetric applications in radiation thera…
New materials for ESR dosimetry in clinical photon and electron beams: Phenol Compounds.
2016
In the last decades several research laboratories have shown an increasing interest aimed at extending the applicability of ESR-dosimetry to radiotherapy with different types of radiation beams. ESR is a spectroscopic method for investigating the structure and dynamics of such paramagnetic species. The concentration of radiation-induced free radicals is proportional to the energy released inside in the medium. Our research group has started an investigation of the ESR response of some phenols compounds for possible ESR dosimetric applications suitable features, such as high efficiency of radiation-matter energy transfer and radical stability at room temperature. In particular, the phenoloct…
Dependence of MRI sensitivity of Fricke gel dosimeters exposed to clinical photons beams on ferrous ammonium sulfate content
2014
Analysis of response of PVA-GTA Fricke gel dosimeters through magnetic resonance imaging.
2017
The experimental activities here reported are focused on the analysis of the clinical applications of Fricke gel dosimeters produced with a matrix of Polyvinyl alcohol (PVA) cross-linked by adding glutaraldehyde (GTA). The analyses were performed by means of a 1.5 T clinical magnetic resonance imaging (MRI) scanner. The sensitivity of these dosimetric gels to clinical photon beams as well as the signal stability were suitably investigated. Furthermore, the effect of the xylenol orange on the MRI signal was analyzed. The results obtained show that these PVA-GTA gel dosimeters show good dosimetric features for possible future use for 3D dose mapping in clinical applications.
Dose verification with EPR/alanine dosimeters in Helical Tomotherapy Stereotactic Radiosurgery (HT SRS) treatments
2016
Intracranial stereotactic radiosurgery (SRS) is a technique to deliver an ablative radiation dose with an extremely sharp dose gradient to small brain tumors. This tecnique allows to deliver high doses of radiation to the tumor sparing the surrounding healthy tissue. In this study the accuracy of the dose delivered in a SRS session by a non conventional radiotherapy machine, the TomoTherapy Hi-Art System, was investigated using an "end-to-end" test. This is perfome d by means of alanine Electron Paramagnetic Resonance (EPR) pe llets. The response of these dosimeters is compared to that of gafchromic films which are particularly suitable for two-dimensional dose verification providing accura…