Search results for "DOSIMETRY"
showing 10 items of 297 documents
Alanine blends for ESR measurements of thermal neutron fluence in a mixed radiation field
2007
In this paper, the results of a study on the electron spin resonance (ESR) dosimetry to measure thermal neutron fluence in a mixed radiation field (neutron and photons) are presented. The ESR responses of alanine dosemeters with different additives are compared. In particular, the (10)B-acid boric and the Gd-oxide were chosen to enhance the sensitivity of alanine dosemeters to thermal neutrons. Irradiations were carried out inside the thermal column of the TAPIRO reactor of the ENEA center, Casaccia Rome. The main results are a greater neutron sensitivity and a smaller lowest detectable fluence for the dosemeters with gadolinium than for dosemeters of alanine with (10)B, which is well known…
Neutron flux and gamma dose measurement in the BNCT irradiation facility at the TRIGA reactor of the University of Pavia
2018
Abstract University of Pavia is equipped with a TRIGA Mark II research nuclear reactor, operating at a maximum steady state power of 250 kW. It has been used for many years to support Boron Neutron Capture Therapy (BNCT) research. An irradiation facility was constructed inside the thermal column of the reactor to produce a sufficient thermal neutron flux with low epithermal and fast neutron components, and low gamma dose. In this irradiation position, the liver of two patients affected by hepatic metastases from colon carcinoma were irradiated after borated drug administration. The facility is currently used for cell cultures and small animal irradiation. Measurements campaigns have been ca…
Dose calculation in biological samples in a mixed neutron-gamma field at the TRIGA reactor of the University of Mainz
2010
To establish Boron Neutron Capture Therapy (BNCT) for non-resectable liver metastases and for in vitro experiments at the TRIGA Mark II reactor at the University of Mainz, Germany, it is necessary to have a reliable dose monitoring system. The in vitro experiments are used to determine the relative biological effectiveness (RBE) of liver and cancer cells in our mixed neutron and gamma fi eld. We work with alanine detectors in combination with Monte Carlo simulations, where we can measure and characterize the dose. To verify our calculations we perform neutron fl ux measurements using gold foil activation and pin-diodes . Material and methods . When L- α -alanine is irradiated with ionizing …
Study of the response of phenol compounds exposed to thermal neutrons beams for Electron Paramagnetic Resonance dosimetry
2015
Abstract This paper reports the results regarding a new organic compound (IRGANOX ® 1076 phenols) with and without low content (5% by weight) of gadolinium oxide (Gd 2 O 3 ) for Electron Paramagnetic Resonance (EPR) dosimetry of neutron beams. The dependence of EPR signal as function of neutron dose was investigated in the fluence range studied between 10 11 cm −2 to 10 14 cm −2 . We evaluated also the effect of gadolinium on 60 Co gamma photon sensitivity of this organic compound. Our analysis showed that a low concentration of gadolinium oxide (of the order of 5% of the total mass of the dosimeter) can enhance the thermal neutron sensitivity more than 10 times with a small reduction of …
EPR DOSIMETRY IN A MIXED NEUTRON AND GAMMA RADIATION FIELD
2004
Suitability of Electron Paramagnetic Resonance (EPR) spectroscopy for criticality dosimetry was evaluated for tooth enamel, mannose and alanine pellets during the 'international intercomparison of criticality dosimetry techniques' at the SILENE reactor held in Valduc in June 2002, France. These three materials were irradiated in neutron and gamma-ray fields of various relative intensities and spectral distributions in order to evaluate their neutron sensitivity. The neutron response was found to be around 10% for tooth enamel, 45% for mannose and between 40 and 90% for alanine pellets according their type. According to the IAEA recommendations on the early estimate of criticality accident a…
12C ion beam dose distribution in presence of medium inhomogeneities: comparison between different measurements and simulations with the treatment pl…
2012
Heavy-ions beams offer several advantages compared to other radiation such as low lateral scattering and high biological effectiveness (RBE) in the Bragg peak region, making them particularly attractive for the treatment of radio-resistant tumours localized close to organs at risk [1]. The extension of ion therapy to new clinical cases requires the exploitation of a dedicated treatment planning system (TPS) based on the existing version of TRiP98 [2,3], established TPS for carbon ions. The theoretical models and experimental databases included in TRiP98 are presently mainly based on measurements in water. This approximation can be applied successfully to reproduce many biological tissues wi…
A program for the independent verification of brachytherapy planning system calculations
2010
Purpose: In this work a spreadsheet based program is presented that to a large extent independently verifies the calculations of individual plans of brachytherapy treatment planning systems for low dose rate, high dose rate and pulsed dose rate techniques.Material and methods: The verification program has been developed based on workbooks/spreadsheets. The treatment planning system output text files are automatically loaded into the new program, allowing the use of the source coordinates, the desired calculation point coordinates, and the dwell times of a patient plan. The source strength and the reference dates are entered by the user and then dose points calculations are independently per…
Dosimetric evaluation of internal shielding in a high dose rate skin applicator
2011
Purpose: The Valencia HDR applicators are accessories of the microSelectron HDR afterloading system (Nucletron) shaped as truncated cones. The base of the cone is either 2 or 3 cm diameter. They are intended to treat skin lesions, being the typical prescription depth 3 mm. In patients with eyelid lesions, an internal shielding is very useful to reduce the dose to the ocular globe. The purpose of this work was to evaluate the dose enhancement from potential backscatter and electron contamination due to the shielding. Material and methods: Two methods were used: a) Monte Carlo simulation, performed with the GEANT4 code, 2 cm Valencia applicator was placed on the surface of a water phantom in …
Impact of the Tiloop Bra mesh in CT images and dose delivery in breast radiotherapy
2012
A new titanized breast mesh, TiLOOP Bra, is currently available for implantation in patients who require radiotherapy. The purpose of this work is to study the dosimetric effect of the presence of a TiLOOP Bra mesh on breast radiation treatment and radiographic imaging. The dosimetric effects have been measured for three X‐ray energies: 1.25 MeV, 6 MV and 18 MV, using radiochromic films placed at three different depths. These depths are representative of mesh location in breast during the radiotherapy treatment and hence, are of interest in this study. In order to assess the disturbance in a radiographic image, different computed tomographic (CT) studies of the mesh have been performed. The…
Technical note: Dosimetric study of a new Co-60 source used in brachytherapy
2007
The purpose of this study is to obtain the dosimetric parameters of a new Co-60 source used in high dose rate brachytherapy and manufactured by BEBIG (Eckert & Ziegler BEBIG GmbH, Germany). The Monte Carlo method has been used to obtain the dose rate distribution in the updated TG-43U1 formalism of the American Association of Physicists in Medicine. In addition, to aid the quality control process on treatment planning systems (TPS), a two-dimensional rectangular dose rate table, coherent with the TG-43U1 dose calculation formalism, is given. These dosimetric data sets can be used as input data of the TPS calculations and to validate them.