Search results for "Data acquisition"
showing 10 items of 237 documents
Comparison of different acquisition patterns for 2D tomographic resistivity surveys
2015
A systematic comparison is presented between some 2D resistivity models and their images by the inversion of synthetic datasets relating to three different arrays, suitable for multichannel data acquisitions (dipole-dipole (DD), Wenner-Schlumberger (WS) and multiple gradient (MG)). The goal is to study how the measurement errors affects the resolution of the tomographic models and the ability to retrieve correct information on buried targets. We considered different data acquisition patterns, gradually increasing the complexity of the combinations of potential spacing and dipolar distance. To this end we increased the number of current dipoles to obtain approximately the same amount of meas…
Low-cost smart energy managment based on ATmega 328P-PU microcontroller
2017
This paper presents a real-time, low-cost, wireless, AC and DC monitoring system based on an ATmega328P-PU microcontroller. The proposed system is composed by different client nodes, which have the task to measure the main electrical quantities involved in the system, and a server node that collects the data and send them to a display device. The system is well suited for a good accuracy monitoring of either AC or DC electrical quantities. In order to verify the correct operation of the system, a case study for the simultaneous monitoring of the DC and AC voltages and currents is provided.
Sequential window acquisition of all theoretical fragments versus information dependent acquisition for suspected-screening of pharmaceuticals in sed…
2019
The aquatic ecosystems are dynamic environments often affected directly or indirectly by a myriad of anthropogenic contaminants that need to be properly identified. In this study, liquid chromatography-quadrupole time-of-flight mass spectrometry (LC-QqTOF-MS) suspected-screening was applied to mussels and riverine sediment both, non-spiked and spiked with a mixture of 32 pharmaceuticals. Three data acquisition methods –sequential window acquisition of all theoretical fragment-ion spectra (SWATH), in fix (FSWATH) and variable (VSWATH) window modes and Information Dependent Acquisition (IDA)– were compared to determine the most suitable acquisition technique. The results obtained in the spike…
TileCal optical multiplexer board 9U prototype
2007
This paper presents the architecture and the status of the optical multiplexer board (OMB) for the ATLAS/LHC Tile hadronic calorimeter (TileCal). This board will analyze the front-end data CRC to prevent bit and burst errors produced by radiation. Besides, due to its position within the data acquisition chain it will be used to emulate front-end data for tests. The first two prototypes of the final OMB 9U version have been produced at CERN. Detailed design issues and manufacture features of these prototypes are described. These prototypes are being validated whereas some firmware developments are being implemented in the programmable devices of the board. Functional descriptions of the boar…
ADC based measurements: Identification of the parameters for the uncertainty evaluation
2009
In the last years, many Authors have dealt with the uncertainty evaluation of the measurement performed by using an analog-to-digital converter, proposing different approach to analyze the uncertainty propagation. In all these studies, it is clearly pointed out that starting from the manufacturer specifications is the least expensive, the least time consuming and, often, the most accurate way to assess the uncertainties. However, the Authors, which have proposed methodologies for the uncertainty assessment, use different parameters as starting point. One of the main reasons which has caused this situation is the coexistent of various Standards concerning the characterization of the analog-t…
Signal integrity studies at optical multiplexer board for TileCal system
2007
6 pages.-- ISI Article Identifier: 000253651800006
Transputer-based parallel system for acquisition and on-line analysis of single-fiber electromyographic signals.
1992
Abstract We describe a transputer-based system suitable for accurate measurements of single-fiber electromyographic jitter. It consists of a conventional electromyograph, a home-made interface and a commercially available transputer-based board installed within a PC/AT compatible. Taking advantage of the concurrent operation of two transputer modules, the system features simultaneous data acquisition and statistical signal processing: while data are acquired and analyzed, a real-time visualization of the signal latency and its variability is provided. In the present configuration, the system can acquire and analyze up to 40,000 consecutive action potentials, which can be grouped into up to …
Quantitative thermoelastic stress analysis by means of low-cost setups
2020
Abstract A low-cost Thermoelastic Stress Analysis (TSA) experimental setup is proposed which uses an ordinary micro-bolometer and in-house developed signal processing scripts. The setup is evaluated by analysing the thermoelastic signal from a tensile and a SENT specimen made of stainless steel AISI 304L, and the bolometer performances are compared with those of a state of the art photon detector. Signal processing is based on off-line cross-correlation, using a self-reference signal which is retrieved from the acquired thermal data. Procedures are in particular developed to recognise, quantify and correct errors due to spectral leakage and loss of streamed frames. The thermoelastic signal …
Testing a new automated single ring infiltrometer for Beerkan infiltration experiments
2015
International audience; The Beerkan method along with BEST algorithms is an alternative technique to conventional laboratory or field measurements for rapid and low-cost estimation of soil hydraulic properties. The Beerkan method is simple to conduct but requires an operator to repeatedly pour known volumes of water through a ring positioned at the soil surface. A cheap infiltrometer equipped with a data acquisition system was recently designed to automate Beerkan infiltration experiments. In this paper, the current prototype of the automated infiltrometer was tested to validate its applicability to the Beerkan infiltration experiment under several experimental circumstances. In addition, t…
Digital background calibration algorithm and its FPGA implementation for timing mismatch correction of time-interleaved ADC
2019
Sample time error can degrade the performance of time-interleaved analog to digital converters (TIADCs). A fully digital background algorithm is presented in this paper to estimate and correct the timing mismatch errors between four interleaved channels, together with its hardware implementation. The proposed algorithm provides low computation burden and high performance. It is based on the simplified representation of the coefficients of the Lagrange interpolator. Simulation results show that it can suppress error tones in all of the Nyquist band. Results show that, for a four-channel TIADC with 10-bit resolution, the proposed algorithm improves the signal to noise and distortion ratio (SN…