Search results for "Data system"

showing 10 items of 14 documents

Inflight Radiometric Calibration of New Horizons' Multispectral Visible Imaging Camera (MVIC)

2017

© 2016 Elsevier Inc. We discuss two semi-independent calibration techniques used to determine the inflight radiometric calibration for the New Horizons’ Multi-spectral Visible Imaging Camera (MVIC). The first calibration technique compares the measured number of counts (DN) observed from a number of well calibrated stars to those predicted using the component-level calibration. The ratio of these values provides a multiplicative factor that allows a conversation between the preflight calibration to the more accurate inflight one, for each detector. The second calibration technique is a channel-wise relative radiometric calibration for MVIC's blue, near-infrared and methane color channels us…

010504 meteorology & atmospheric sciencesMultispectral imageFOS: Physical sciencesField of view01 natural sciencesOptics0103 physical sciencesCalibration010303 astronomy & astrophysicsRadiometric calibrationInstrumentation and Methods for Astrophysics (astro-ph.IM)0105 earth and related environmental sciencesRemote sensingEarth and Planetary Astrophysics (astro-ph.EP)Pixelbusiness.industryDetectorAstrophysics::Instrumentation and Methods for AstrophysicsAstronomy and AstrophysicsPlanetary Data SystemPanchromatic filmSpace and Planetary ScienceEnvironmental scienceAstrophysics::Earth and Planetary AstrophysicsAstrophysics - Instrumentation and Methods for AstrophysicsbusinessAstrophysics - Earth and Planetary Astrophysics
researchProduct

Reliability of extracellular contrast versus gadoxetic acid in assessing small liver lesions using liver imaging reporting and data system v.2018 and…

2022

Background & aims: The diagnostic accuracy of Liver Imaging Reporting and Data System (LI-RADS) v.2018 and European Association for the Study of the Liver (EASL) criteria for the diagnosis of HCC have been widely evaluated, but their reliability should be investigated. We aimed to assess and compare the reliability of LI-RADS v.2018 and EASL criteria for the diagnosis of HCC using MRI with extracellular contrast agents (ECAs) and gadoxetic acid (GA) and determine the effect of ancillary features on LI-RADS reliability. Approach & results: Ten readers reviewed MRI studies of 92 focal liver lesions measuring <3 cm acquired with ECAs and GA <1 month apart from two prospective tri…

Carcinoma HepatocellularHepatology[SDV]Life Sciences [q-bio]Liver NeoplasmsContrast MediaReproducibility of ResultsHepatocellular CarcinomaliverMagnetic Resonance ImagingSensitivity and SpecificityHumansData SystemsProspective StudiesRetrospective Studies
researchProduct

DAQs-based wattmeters for high accuracy measurements. Comparison with the Italian power primary standard

2013

Abstract This paper is focused on the use of data acquisition boards (DAQs) for the development of high accuracy PC-based instruments for the measurements of electrical power. The proposed systems are simple, portable and low cost because they are based on commercial data acquisition boards (DAQs) connected to a common personal computer. Data processing is carried out by a commercial software based on an interpolating windowed FFT. In the paper it is shown how the voltage can be sensed directly, thanks to the DAQ input range, thus avoiding expensive voltage dividers. The set up of the DAQs-based solutions is described and the evaluation of their metrological features is made by means of a c…

Commercial softwareData processingEngineeringbusiness.industryApplied MathematicsVoltage dividerPower measurement Data acquisition Wattmeters Power system measurement Sampled data system PC-based instrumentCondensed Matter PhysicsData acquisitionVoltmeterPrimary standardPersonal computerElectronic engineeringElectric powerElectrical and Electronic EngineeringbusinessSettore ING-INF/07 - Misure Elettriche E ElettronicheInstrumentationMeasurement
researchProduct

Development of a high-accuracy PC-based wattmeter with commercial data acquisition boards

2011

This paper presents the development of a high accuracy sampling wattmeter, which makes use of two commercial data acquisition boards (DAQs) connected to a common personal computer. Commercial software is also used for data processing and implementation of the virtual instrument. The set up of the PC-based wattmeter is described and a preliminary evaluation of its metrological performances is made by means of two series of experimental tests, which were carried out with an electric power standard and a high performance multifunction calibrator. © 2011 IEEE.

EngineeringVirtual instrumentElectric power measurementPC-basedlaw.inventionSet (abstract data type)Data acquisitionSampling (signal processing)lawExperimental testElectronic engineeringMeasurement theorySampled data control systemsCommercial softwareData processingpower measurements data acquisition wattmeters power system measurements sampled data systems PC-based instrumentsVirtual instrumentationData acquisition boardbusiness.industryMetrological performanceWattmeterData handlingCommercial softwareElectric powerPersonal computersSampled data systemsPower qualityPower system measurementPersonal computerHigh-accuracyInstrumentsbusinessWattmetersSettore ING-INF/07 - Misure Elettriche E Elettroniche2011 IEEE International Instrumentation and Measurement Technology Conference
researchProduct

In BOLD we trust? A commentary on the reliability of specimen identification for DNA barcoding: a case study on burrower bugs (Hemiptera: Heteroptera…

2016

An assessment was performed regarding the accuracy of various types of data deposited in the Barcode of Life Data system (BOLD) related to the true bug family Cydnidae (Hemiptera: Heteroptera). Taxonomic nomenclature and classification, identification reliability, and the correctness of the data provided in the “Taxon description” were analyzed and commented on with respect to both available versions of the BOLD system, i.e. version 3 and beta version 4. Numerous mistakes in taxonomy, the relevance of the taxa names, and species misidentifications in BOLD version 3 were found and, more importantly, similar errors were detected in BOLD version 4 as well. We suggest that if the BOLD system is…

Hemipterataxonomytrue bugsBarcode of Life Data systemnomenclaturePentatomoideaidentification accuracyZootaxa : A mega-journal for zoological taxonomists in the world
researchProduct

Hybrid nonlinear observer for Inertial Navigation

2016

This paper considers the problem of designing an observer for navigation and localization of inertial systems. Since the measurement systems used in this field have a low update rate with respect to the control algorithm, the design of a suitable observer with sampled measurements is required. Here a hybrid non-linear observer is proposed, combining two different observers with different characteristics. A theoretical treatment is given in order to prove the convergence of the observer and it will be contextualized in the framework of the hybrid systems, providing an elegant setting for the proposed solution. Finally experimental results show the feasibility of the proposed observer and the…

Hybrid observer0209 industrial biotechnologyEngineeringObserver (quantum physics)010505 oceanographybusiness.industry02 engineering and technologyKalman filterInertial navigationSeparation principle01 natural sciences020901 industrial engineering & automationSample-data systemsSettore ING-INF/04 - AutomaticaControl theoryHybrid systemGlobal Positioning SystemState observerbusinessAlpha beta filterInertial navigation system0105 earth and related environmental sciences2016 IEEE 25th International Symposium on Industrial Electronics (ISIE)
researchProduct

Contrast ultrasound LI-RADS LR-5 identifies hepatocellular carcinoma in cirrhosis in a multicenter restropective study of 1,006 nodules

2018

Background & Aims The use of contrast enhanced ultrasound (CEUS) for the diagnosis of hepatocellular carcinoma (HCC) in cirrhosis was questioned because of the risk of a false positive diagnosis in cases of cholangiocarcinoma. The American College of Radiology has recently released a scheme (CEUS Liver Imaging Reporting and Data System [LI-RADS®]) to classify lesions at risk of HCC investigated by CEUS. The aim of the present study was to validate this LI-RADS scheme for the diagnosis of HCC. Methods A total of 1,006 nodules from 848 patients with chronic liver disease at risk of HCC were collected in five Italian centers and retrospectively analyzed. Nodules were classified as LR-5, (HCC) …

Liver CirrhosisMaleCirrhosisContrast enhanced ultrasoundContrast MediaChronic liver diseaseGastroenterology030218 nuclear medicine & medical imagingCholangiocarcinoma0302 clinical medicineDiagnosisMedicineTomographyWashoutUltrasonographyUltrasoundLiver NeoplasmsMiddle AgedMagnetic Resonance ImagingX-Ray ComputedLiverHepatocellular carcinoma030211 gastroenterology & hepatologyFemaleRadiologymedicine.symptomAlgorithmsContrast-enhanced ultrasoundAdultmedicine.medical_specialtyCarcinoma HepatocellularDiagnosis Differential03 medical and health sciencesInternal medicineHumansDiagnostic ErrorsneoplasmsAgedLiver Imaging Reporting And Data System (LI-RADS)Hepatologybusiness.industryCarcinomaSettore MED/09 - MEDICINA INTERNAReproducibility of ResultsHepatocellularRetrospective cohort studyHistologyNodule (medicine)medicine.diseaseImage Enhancementdigestive system diseasesArterial hyperenhancementDifferentialbusinessTomography X-Ray Computed
researchProduct

A new proposed cloud computing based architecture for space ground data systems

2018

International audience; Many companies decided to move towards the cloud computing technology in order to manage, monitor and explore huge space data amount in the space ground data systems. The corresponding transition adaptation needs a study to classify each space related service in the appropriate cloud computing service model layer; SaaS, PaaS and IaaS. In this paper, we specify a representation of proposed cloud computing based ground data system architecture for earth observation missions. The proposed architecture takes into consideration the collaboration aspect between multiple space agencies. We evaluate the time, storage and processing performance when using the cloud computing …

Network architectureService (systems architecture)Earth observationComputer Networks and Communicationsbusiness.industryComputer scienceQuality of serviceSoftware as a serviceDistributed computingNetwork architectureQoS020206 networking & telecommunicationsCloud computing02 engineering and technologySpace mission0202 electrical engineering electronic engineering information engineeringSystems architectureCloud computingGround data systemData system[INFO]Computer Science [cs]020201 artificial intelligence & image processingbusinessInternational Journal of Communication Networks and Distributed Systems
researchProduct

Expanding the Liver Imaging Reporting and Data System (LI-RADS) v2018 diagnostic population: performance and reliability of LI-RADS for distinguishin…

2018

Abstract Background Hepatocellular carcinoma (HCC) can be diagnosed using imaging criteria in patients at high-risk for HCC, according to Liver Imaging Reporting and Data System (LI-RADS) guidelines. The aim of this study was to determine the diagnostic performance and inter-rater reliability (IRR) of LI-RADS v2018 for differentiating HCC from non-HCC primary liver carcinoma (PLC), in patients who are at increased risk for HCC but not included in the LI-RADS ‘high-risk’ population. Methods This retrospective HIPAA-compliant study included a 10-year experience of pathologically-proven PLC at two liver transplant centers, and included patients with non-cirrhotic hepatitis C infection, non-cir…

OncologyMalemedicine.medical_specialtyCarcinoma HepatocellularPopulationSensitivity and SpecificityCholangiocarcinoma03 medical and health sciences0302 clinical medicineInternal medicineCarcinomaMedicineData SystemsHumanseducationneoplasmsAgedRetrospective Studieseducation.field_of_studyLI-RADS Hepatocellular carcinomaHepatologymedicine.diagnostic_testbusiness.industryFatty liverLiver NeoplasmsGastroenterologyReproducibility of ResultsMagnetic resonance imagingRetrospective cohort studyHepatitis CHepatitis C Chronicmedicine.diseaseMagnetic Resonance Imagingdigestive system diseasesFatty Liver030220 oncology & carcinogenesisHepatocellular carcinomaCohort030211 gastroenterology & hepatologyFemalebusinessTomography X-Ray ComputedSettore MED/36 - Diagnostica Per Immagini E Radioterapia
researchProduct

Magnetic Resonance Imaging of Nonhepatocellular Malignancies in Chronic Liver Disease.

2021

Hepatocellular carcinoma (HCC) is the most common liver malignancy associated with chronic liver disease. Nonhepatocellular malignancies may also arise in the setting of chronic liver disease. The imaging diagnosis of non-HCC malignancies may be challenging. Non-HCC malignancies in patients with chronic liver disease most commonly include intrahepatic cholangiocarcinoma and combined hepatocellular-cholangiocarcinoma, and less commonly hepatic lymphomas and metastases. On MR imaging, non-HCC malignancies often demonstrate a targetoid appearance, manifesting as rim arterial phase hyperenhancement, peripheral washout, central delayed enhancement, and peripheral restricted diffusion. When apply…

Pathologymedicine.medical_specialtyCirrhosisCarcinoma HepatocellularHepatocellular carcinomaLiver imaging reporting and data systemContrast MediaMalignancyChronic liver diseaseMetastasisMetastasismedicineHumansRadiology Nuclear Medicine and imagingneoplasmsIntrahepatic CholangiocarcinomaIntrahepatic cholangiocarcinomaCirrhosimedicine.diagnostic_testbusiness.industryLiver NeoplasmsMagnetic resonance imagingCombined hepatocellular-cholangiocarcinomamedicine.diseaseMagnetic Resonance Imagingdigestive system diseasesBile Ducts IntrahepaticBile Duct NeoplasmsHepatocellular carcinomabusinessArterial phaseMagnetic resonance imaging clinics of North America
researchProduct