Search results for "Database"
showing 10 items of 2136 documents
Experimental and theoretical investigations of structural isomers of dichalcogenoimidodiphosphinate dimers: dichalcogenides or spirocyclic contact io…
2007
A synthetic protocol for the tert-butyl-substituted dichalcogenoimidodiphosphinates [Na(tmeda){(EPtBu(2))(2)N}] (3 a, E=S; 3 b, E=Se; 3 c, E=Te) has been developed. The one-electron oxidation of the sodium complexes [Na(tmeda){(EPR(2))(2)N}] with iodine produces a series of neutral dimers (EPR(2)NPR(2)E--)(2) (4 b, E=Se, R=iPr; 4 c, E=Te, R=iPr; 5 a, E=S, R=tBu; 5 b, E=Se, R=tBu; 5 c, E=Te, R=tBu). Attempts to prepare 4 a (E=S, R=iPr) in a similar manner produced a mixture including HN(SPiPr(2)). Compounds 4 b, 4 c and 5 a-c were characterised by multinuclear NMR spectra and by X-ray crystallography, which revealed two alternative structures for these dimeric molecules. The derivatives 4 b,…
Structural study of ethyl 3-arylcarbamoyl-2,3-diazabicyclo[2.2.1]hept-5-ene-2-carboxylates: conformation and transmission of substituent effects acro…
2001
Nine new ethyl 3-arylcarbamoyl-2,3-diazabicyclo[2.2.1]hept-5-ene-2-carboxylates were prepared by a [4 + 2] cycloaddition and their FTIR, 1H, 13C and 15N NMR spectra were measured and assigned. Single crystals were grown for five compounds and their X-ray data were obtained. The electronic structure and the conformations were calculated by the semi-empirical AM1 method. Using correlations between the spectral, empirical and theoretical structural data, the transmission of substituent effects and the preferential conformation connected with the consecutive double nitrogen inversion and regarding the mutual orientation of NH and CO bonds were investigated. The results are compared with those f…
Child-centered and teacher-directed practices in relation to calculation and word problem solving skills
2019
Abstract This study examined transactional associations between classroom-level math skills and teaching practices. Participants were 523 children from 31 classrooms. Math skills were assessed three times. Teaching practices were observed in Grades 1 and 3. Child-centered practices promoted subsequent calculation skills whereas teacher-directed practices were associated with a lower level of calculation skills. Higher problem-solving skills at Grade 2 predicted more child-centered practices and less teacher-directed practices in third grade. Moreover, calculation skills mediated the effect of child-centered practices on problem-solving skills. The results suggest that teaching practices and…
Areas of research and clinical approaches to the study of liver abscess
2016
AIM To analyze the research activity on liver abscess (LA) and identify the main topic clusters in the area. METHODS We identified all documents using the medical subject heading "LA" indexed in the MEDLINE database between 2001 and 2015. We performed a descriptive bibliometric analysis, characterizing the evolution of scientific activity, the publication types of the documents, the document categories of clinical interest (case reports, clinical trials, evaluation studies, meta-analysis, observational studies, practice guidelines and validation studies) and the geographic distribution of the research. We also carried out an analysis of networks and research clusters in order to identify th…
BONDED SILICA PHASES FOR THE SEPARATION OF BIOPOLYMERS BY MEANS OF COLUMN LIQUID CHROMATOGRAPHY
1988
(1Z,3Z)-3-[Quinolin-2(1H)-ylidene]-1-(quinolin-2-yl)prop-1-en-2-ol: An unexpected most stable tautomer of 1,3-bis(quinolin-2-yl)acetone
2009
Abstract 1 H, 13 C and 15 N NMR spectra reveal that CDCl 3 solution of 1,3-bis(quinolin-2-yl)acetone contains only ( 1Z , 3Z )-3-[quinolin-2(1 H )-ylidene]-1-(quinolin-2-yl)prop-1-en-2-ol. The proton transfer takes place between two basic centers of the molecule, which means that the process is an identity reaction by character. The situation is completely different from that detected in chloroform solution of 1,3-bis(pyridin-2-yl)acetone where three different tautomers are in equilibrium with each other. Although the proton transfers in both ( 1Z , 3Z )-3-[quinolin-2(1 H )-ylidene]-1-(quinolin-2-yl)prop-1-en-2-ol and ( 1Z , 3Z )-3-hydroxy-1-[quinolin-2(1 H )-ylidene-4-quinolin-2-yl]but-3-e…
Approaches to characterise chromatographic column performance based on global parameters accounting for peak broadening and skewness.
2009
Peak broadening and skewness are fundamental parameters in chromatography, since they affect the resolution capability of a chromatographic column. A common practice to characterise chromatographic columns is to estimate the efficiency and asymmetry factor for the peaks of one or more solutes eluted at selected experimental conditions. This has the drawback that the extra-column contributions to the peak variance and skewness make the peak shape parameters depend on the retention time. We propose and discuss here the use of several approaches that allow the estimation of global parameters (non-dependent on the retention time) to describe the column performance. The global parameters arise f…
A complementary mobile phase approach based on the peak count concept oriented to the full resolution of complex mixtures
2011
Situations of minimal resolution are often found in liquid chromatography, when samples that contain a large number of compounds, or highly similar in terms of structure and/or polarity, are analysed. This makes full resolution with a single separation condition (e.g., mobile phase, gradient or column) unfeasible. In this work, the optimisation of the resolution of such samples in reversed-phase liquid chromatography is approached using two or more isocratic mobile phases with a complementary resolution behaviour (complementary mobile phases, CMPs). Each mobile phase is dedicated to the separation of a group of compounds. The CMPs are selected in such a way that, when the separation is cons…
Multidimensional Column Liquid Chromatography (LC) in Proteomics – Where Are We Now?
2006
SilicaROD™ — A new challenge in fast high-performance liquid chromatography separations
1998
Abstract High performance liquid chromatography (HPLC) has become one of the most used methods for the analysis of compound mixtures in industry, especially for the quality control of products. Nowadays productivity is the major and dominant upcoming issue, i.e. the goal is to drastically reduce the analysis time and cost per analysis. The solution of the task is higher throughput and faster HPLC methods. Here we describe a new monolithic type of HPLC column, the SilicaROD™ column, which permits the fast HPLC separation of compound mixtures within a few minutes.