Search results for "Daylight"

showing 10 items of 45 documents

Assessing the lighting systems flexibility for reducing and managing the power peaks in smart grids

2020

Abstract The application of “shiftable” or “modulable” load (i.e. washing machine, dishwasher, etc.) in a Smart Grid, can provide energy saving or modify the power flows in the grid, allowing a reduction of the electrical power peak. This paper explores the possibility to modulate the indoor artificial lighting to support this reduction. The study examines the impact of two different measures of power shaving. On the one hand, the change of Correlated Colour Temperature of the light source, and, on the other hand, the dimming of its luminous flux. The possibility to merge the above-mentioned technical solutions is also analyzed. Based on these strategies, several daily schedules of lighting…

Settore ING-IND/11 - Fisica Tecnica AmbientaleComputer science020209 energyMechanical Engineering02 engineering and technologyBuilding and ConstructionManagement Monitoring Policy and LawColor temperatureGridAutomotive engineeringSettore ING-IND/33 - Sistemi Elettrici Per L'EnergiaLuminous fluxEnergy efficiencyGeneral EnergySmart grid020401 chemical engineeringAbsorbed powerControl system0202 electrical engineering electronic engineering information engineeringModulable loadsDaylightElectric power0204 chemical engineeringLightingBACApplied Energy
researchProduct

Comparison between the performances of daylight linked control system at two different latitudes

2019

The aim of this work is to compare the performance of a daylight-linked control system installed and tested in two different case studies by means of a set of indices. The two case studies are characterized by different geometry, location and windows orientation. The first one is located at the ENEA premises in Lampedusa (IT, 35° 30' N); the second one is located in Palermo (IT, 38°6' N) on the third floor of the building 9 of the Department of Engineering if the University of Palermo. In both cases, the indices were calculated by using the same daylight-linked control system and the same end-use (office). The results were reported and analysed in order to demonstrate as the performances of…

Settore ING-IND/11 - Fisica Tecnica AmbientaleControl systemClimatologyEnvironmental scienceDaylight-linked control systemDaylightDaylight-building automation controlLightingLatitude
researchProduct

Calculation of Energy Performance Indices of Daylight Linked Control Systems by Monitored Data

2017

The actual performances of Building Automation systems are often lower than the ideal ones. In order to investigate the actual performance of a Building Automation system for lighting control, a large stock of collected data, including indoor illuminance and absorbed electric power, have been presented and analysed in this paper. The measures have been taken during one year, in a laboratory located at the University of Palermo, where different lighting control systems, produced by two different manufacture companies, have been installed. As demonstrated in literature, many factors affecting energy savings’ evaluation in lighting control systems are the position and the typology of the senso…

Settore ING-IND/11 - Fisica Tecnica AmbientaleControl systemEnergy performanceEnvironmental scienceDaylightDaylight control system Building automation system lighting indices daylightingAutomotive engineeringProceedings of SWC2017/SHC2017
researchProduct

Automated control systems for indoor lighting: from design to actual performances' assessment

In recent years, but already around 1980, many buildings have been equipped with Building Automation and Control (BAC) systems. These systems were applied as a normal upgrade of traditional systems in different field of the industrial sector. In general, they can be applied to the building plants in order to carry out a series of functions. The main benefits of the installation of this kind of system are well known. First of all, it has been shown that BACs systems installation increases the energy savings and because using many typologies of sensors (e.g. presence detectors to control lighting system) and because, by monitoring the data it is possible to modify plant’s strategies and also …

Settore ING-IND/11 - Fisica Tecnica AmbientaleDaylight linked control systems daylight lighting lighting control system Building Automation Control systems
researchProduct

The impact of the software’s choice on dynamic daylight simulations’ results: A comparison between Daysim and 3ds Max Design®

2015

Abstract Evaluating indoor daylight availability is extremely important in order to define the characteristics of an environment in terms of visual comfort and energy performances of lighting systems. The criticism of the static calculation approach based on Daylight Factor led to the development of the Climate Based Daylight Modeling (CBDM) one. Dynamic simulations are performed thanks to the use of specific software and the choice of a calculation tool or another could provide different output results. Therefore the aim of this paper is to compare results of dynamic daylight simulations carried out with two different software, Daysim and 3ds Max Design® and referred to a simple office loc…

Settore ING-IND/11 - Fisica Tecnica AmbientaleDaylight simulationRenewable Energy Sustainability and the EnvironmentComputer sciencebusiness.industryOrientation (computer vision)Dynamic daylight metricsDynamic daylight metricDaylight factorEnergy efficiencyOpticsSoftwareGeneral Materials SciencePoint (geometry)DaylightbusinessDaylightingEnergy (signal processing)SimulationDaylightingEfficient energy useSolar Energy
researchProduct

Sustainable lighting design through the analysis of spatial and time non-uniformities in natural lighting with the metric of the information theory

2014

The indoor visual comfort of subjects faced with indoor ambient lighting varies with the position of the subject and is not constant over time. Average performance indexes, such as the mean value of Daylight Factor and Daylight Autonomy, are commonly used to analyse lighting distribution. These indexes, however, don’t properly take into account either the spatial or the time distribution of values affecting the non-uniformity of environmental lighting. Indeed, these are limited to the definition of a mean value or to the assessment of time availability of daylighting. This paper examines spatial and temporal non-uniformities in indoor lighting as possible causes of discomfort for occupants.…

Settore ING-IND/11 - Fisica Tecnica AmbientaleInformation Theory Visual Comfort Daylight Factor Daylight Autonomy Lecture halls.
researchProduct

The role of weather data files in Climate-based Daylight Modeling

2015

Abstract This paper illustrates the results of daylight simulations of a simple standalone office carried out using different weather data files (IWEC, Meteonorm, Satel-Light and TRY), for five European locations (Copenhagen, London, Milan, Nancy, Rome). The aim was to analyze the impact of choosing one weather file or another on the prediction of daylight availability in an indoor environment. Results were analyzed both in terms of Annual and Monthly Light Exposures and dynamic daylight performance metrics. It was demonstrated that IWEC, Meteonorm and Satel-Light weather files determine similar outcomes, instead TRY weather data always produces considerably lower values. Moreover the diffe…

Settore ING-IND/11 - Fisica Tecnica AmbientaleMeteorologyDynamic daylight simulationRenewable Energy Sustainability and the EnvironmentWeather data fileWeather dataMaterials ScienceIndoor environmentDynamic daylight performance metricEnvironmental scienceGeneral Materials ScienceDaylightIndoor environment quality
researchProduct

Assessing lighting quality in indoor environments

Settore ING-IND/11 - Fisica Tecnica Ambientalelighting quality non visual effects of light dynamic daylight simulations perception of light
researchProduct

RESEARCH ON MICROCLIMATE LIGHT CONDITIONS IN A SCHOLASTIC ENVIRONMENT, BASED ON ADAPTIVE MODEL

2010

This paper shows the results of a deep research, carried out on a scholastic setting and based on a questionnaire, to evaluate the light microclimate and the satisfaction degree of the users. Through simulations, we have previously identified a number of classrooms where the conditions could be critical, both in terms of over-lightning, glare and disrespected values (suggested by the current normative). The proposed method consist in using device-made-surveys, a simulation software and questionnaires submission to users of the studied rooms. The questionnaires, based on an adaptive model, has been developed to detect subjective data (place, visus…) and other information about the setting an…

Settore ING-IND/11 - Fisica Tecnica Ambientalevisual comfort daylight factor adaptive model light microclimate.
researchProduct

Experimental Set up of Advanced Lighting Systems for Load Shifting Strategies

2021

Shiftable and modulable loads are an essential part of smart grids in the effort for improving the efficiency of the power system and providing new ancillary services. Most of the researches considered shiftable loads and the impact on the power grid. Smart lighting systems are able to modulate their consumption while preserving the visual duty, therefore they can take part to this action. In this context, this paper presents an advanced experimental setup implemented in the SolarLab of the University of Palermo, with the aim of studying the impact on the end-user's energy consumption and on the power grid of smart lighting systems. In this light, different control strategies will be consid…

Settore ING-IND/33 - Sistemi Elettrici Per L'Energiashiftable loadBuilding Automationsmart lightingDaylight-Linked control systemCCT2021 IEEE International Conference on Environment and Electrical Engineering and 2021 IEEE Industrial and Commercial Power Systems Europe (EEEIC / I&CPS Europe)
researchProduct