Search results for "DePFET"
showing 10 items of 12 documents
The Wide Field Imager instrument for Athena
2017
ESA's next large X-ray mission ATHENA is designed to address the Cosmic Vision science theme 'The Hot and Energetic Universe'. It will provide answers to the two key astrophysical questions how does ordinary matter assemble into the large-scale structures we see today and how do black holes grow and shape the Universe. The ATHENA spacecraft will be equipped with two focal plane cameras, a Wide Field Imager (WFI) and an X-ray Integral Field Unit (X-IFU). The WFI instrument is optimized for state-of-The-Art resolution spectroscopy over a large field of view of 40 amin x 40 amin and high count rates up to and beyond 1 Crab source intensity. The cryogenic X-IFU camera is designed for high-spect…
Development of the Pixel Detector for the Belle II experiment and top quark mass measurement in radiative events at the future electron-positron line…
2019
Durante los últimos cien años, los numerosos descubrimientos en los colisionadores de partículas y desarrollos teóricos han conducido a los físicos de partículas a construir el Modelo Estándar, el modelo teórico más exitoso hasta la fecha. Sin embargo, a pesar de su gran éxito, el Modelo Estándar no describe toda la fenomenología observada actualmente en los diferentes experimentos. Es por ello que se necesitan nuevos colisionadores que proporcionen observaciones de nueva física que nos ayuden a construir modelos que describan dicha fenomenología. Para enfrentarse al reto, la comunidad de física de partículas se une formando grandes colaboraciones, con el propósito de diseñar y construir lo…
The DEPFET based Focal Plane Detectors for MIXS on BepiColombo
2010
X-ray detectors based on arrays of DEPFET macropixels, which consist of a silicon drift detector combined with a detector/amplifier structure DEPFET as readout node, provide a convenient and flexible way to adapt the pixel size of a focal plane detector to the resolving power of any given X-ray optical system. Macropixels combine the traditional benefits of an SDD, like scalability, arbitrary geometry and excellent QE even in the low energy range, with the advantages of DEPFET structures: Charge storage capability, near Fano-limited energy resolution, low power consumption and high speed readout. Being part of the scientific payload of ESA's BepiColombo mission, the MIXS instrument will be …
Belle II pixel detector: Performance of final DEPFET modules
2020
Belle-II DEPFET and PXD Collaboration: et al.
DEPFET pixel detector in the Belle II experiment
2019
Belle II DEPFET and PXD Collaboration: et al.
Development of the wide field imager for Athena
2015
The WFI (Wide Field Imager) instrument is planned to be one of two complementary focal plane cameras on ESA's next X-ray observatory Athena. It combines unprecedented survey power through its large field of view of 40 arcmin x 40 arcmin together with excellent count-rate capability (>= 1 Crab). The energy resolution of the silicon sensor is state-of-the-art in the energy band of interest from 0.2 keV to 15 keV, e.g. the full width at half maximum of a line at 6 keV will be <= 150 eV until the end of the nominal mission phase. This performance is accomplished by using DEPFET active pixel sensors with a pixel size of 130 μm x 130 μm well suited to the on-axis angular resolution of 5 arcsec of…
DEPFET Active Pixel Detectors for a Future Linear e(+)e(-) Collider
2013
arXiv:1212.2160v1.-- et al.
The Wide Field Imager of the International X-ray Observatory
2010
The International X-ray Observatory (IXO) will be a joint X-ray observatory mission by ESA, NASA and JAXA. It will have a large effective area (3 m 2 at 1.25 keV) grazing incidence mirror system with good angular resolution (5 arcsec at 0.1–10 keV) and will feature a comprehensive suite of scientific instruments: an X-ray Microcalorimeter Spectrometer, a High Time Resolution Spectrometer, an X-ray Polarimeter, an X-ray Grating Spectrometer, a Hard X-ray Imager and a Wide-Field Imager. The Wide Field Imager (WFI) has a field-of-view of 18 ft � 18 ft. It will be sensitive between 0.1 and 15 keV, offer the full angular resolution of the mirrors and good energy resolution. The WFI will be imple…
The IXO Wide-Field Imager
2010
The Wide Field Imager (WFI) of the International X-ray Observatory (IXO) is an X-ray imaging spectrometer based on a large monolithic DePFET (Depleted P-channel Field Effect Transistor) Active Pixel Sensor. Filling an area of 10 × 10 cm² with a format of 1024 × 1024 pixels it will cover a field of view of 18 arcmin. The pixel size of 100 × 100 μm² corresponds to a fivefold oversampling of the telescope's expected 5 arcsec point spread function. The WFI's basic DePFET structure combines the functionalities of sensor and integrated amplifier with nearly Fano-limited energy resolution and high efficiency from 100 eV to 15 keV. The development of dedicated control and amplifier ASICs allows for…
The wide-field imager for IXO: status and future activities
2010
The Wide Field Imager (WFI) of the International X-ray Observatory (IXO) is an X-ray imaging spectrometer based on a large monolithic DePFET (Depleted P-channel Field Effect Transistor) Active Pixel Sensor. Filling an area of 10 x 10 cm2 with a format of 1024 x 1024 pixels it will cover a field of view of 18 arcmin. The pixel size of 100 x 100 μm2 corresponds to a fivefold oversampling of the telescope's expected 5 arcsec point spread function. The WFI's basic DePFET structure combines the functionalities of sensor and integrated amplifier with nearly Fano-limited energy resolution and high efficiency from 100 eV to 15 keV. The development of dedicated control and amplifier ASICs allows for…