Search results for "Dead Time"

showing 2 items of 22 documents

SPI/INTEGRAL in-flight performance

2003

The SPI instrument has been launched on-board the INTEGRAL observatory on October 17, 2002. SPI is a spectrometer devoted to the sky observation in the 20 keV-8 MeV energy range using 19 germanium detectors. The performance of the cryogenic system is nominal and allows to cool the 19 kg of germanium down to 85 K with a comfortable margin. The energy resolution of the whole camera is 2.5 keV at 1.1 MeV. This resolution degrades with time due to particle irradiation in space. We show that the annealing process allows the recovery of the initial performance. The anticoincidence shield works as expected, with a low threshold at 75 keV, reducing the GeD background by a factor of 20. The digital …

media_common.quotation_subjectAstrophysics::High Energy Astrophysical PhenomenaFOS: Physical scienceschemistry.chemical_elementGermaniumAstrophysicsUNESCO::ASTRONOMÍA Y ASTROFÍSICAAstrophysicsGamma-rayObservatoryinstrument observations [gamma-ray]Observationsmedia_commonPhysicsSpectrometerINTEGRAL/SPIAstrophysics (astro-ph)DetectorAstronomy and AstrophysicsInstrumentDead timeGalactic planeINTEGRAL/SPI [space telescope]:ASTRONOMÍA Y ASTROFÍSICA::Cosmología y cosmogonia [UNESCO]Gamma-ray ; Instrument ; Observations ; Space telescope ; INTEGRAL/SPIComputational physicsCrab NebulachemistrySpace and Planetary ScienceSkySpace telescopeUNESCO::ASTRONOMÍA Y ASTROFÍSICA::Cosmología y cosmogonia:ASTRONOMÍA Y ASTROFÍSICA [UNESCO]
researchProduct

Microscale X-ray mapping of CZT arrays: Spatial dependence of amplitude, shape and multiplicity of detector pulses

2018

In this work, we present the results of a microscale X-ray mapping of a 2 mm thick CZT pixel detector, with pixel pitches of 500 μm and 250 μm, using collimated synchrotron X-ray sources at the Diamond Light source (U. K.). The detector is dc coupled to a fast and low noise ASIC (PIXIE ASIC), characterized only by the preamplifier stage. A custom 16-channel digital readout electronics was used, able to perform online fast pulse shape and height analysis (PSHA), with low dead time and reasonable energy resolution at both low and high fluxes. The detector allows high bias voltage operation (> 5000 V/cm) and good energy resolution at room temperature (5.3 %, 2.3 % and 2.1 % FWHM at 22.1, 59…

radiation detectorRadiology Nuclear Medicine and ImagingNuclear and High Energy PhysicsMaterials sciencePreamplifier01 natural sciencesCollimated light030218 nuclear medicine & medical imagingCharge sharinglaw.invention03 medical and health sciences0302 clinical medicineOpticslaw0103 physical scienceshigh fluxmappingInstrumentation010308 nuclear & particles physicsbusiness.industryASICDetectorBiasingDead timeSynchrotronSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)CZTFull width at half maximumsinchrotron radiationbusiness
researchProduct