Natural history of the Sprint Fidelis lead: survival analysis from a large single-center study.
2012
The purposes of our study were to: (1) determine lead failure rate in a large single-center cohort of Sprint Fidelis 6949 (Fidelis) leads, (2) define the risk of lead failure over time, (3) assess the impact of the Lead Integrity Alert (LIA) on lead failure presentation, and (4) identify independent predictors of Fidelis lead failure. All patients who underwent implantation of a Fidelis lead between September 2004 and July 2007 were included. Demographic, clinical, and device characteristics at the time of implant and prior to failure were collected and analyzed. A total of 971 Fidelis leads (706 men, 265 women, mean age 68.4 ± 12.8 years) were implanted. Over a mean follow-up of 46.3 month…
Efficacy of a web-based intervention for improving psychosocial well-being in patients with implantable cardioverter-defibrillators: the randomized c…
2019
Abstract Aims Anxiety, depression, and reduced quality of life (QoL) are common in patients with implantable cardioverter-defibrillators (ICDs). Treatment options are limited and insufficiently defined. We evaluated the efficacy of a web-based intervention (WBI) vs. usual care (UC) for improving psychosocial well-being in ICD patients with elevated psychosocial distress. Methods and results This multicentre, randomized controlled trial (RCT) enrolled 118 ICD patients with increased anxiety or depression [≥6 points on either subscale of the Hospital Anxiety and Depression Scale (HADS)] or reduced QoL [≤16 points on the Satisfaction with Life Scale (SWLS)] from seven German sites (mean age 58…
Should subcutaneous implantable cardioverter-defibrillators be implanted in patients who are candidates for continuous flow left ventricular assist d…
2017
Impact of Midregional N‐Terminal Pro–Atrial Natriuretic Peptide and Soluble Suppression of Tumorigenicity 2 Levels on Heart Rhythm in Patients Treate…
2021
Background We assessed the impact of preprocedural plasma levels of MRproANP (midregional N‐terminal pro–atrial natriuretic peptide) and sST2 (soluble suppression of tumorigenicity 2) on recurrence of atrial fibrillation (AF) at 1 year after catheter ablation of AF. Methods and Results This was a prospective, multicenter, observational study including patients undergoing catheter ablation of AF. MRproANP and sST2 were measured in a peripheral venous blood preprocedure, and MRproANP was assessed in the right and left atrial blood during ablation. The primary end point was recurrent AF between 3 and 12 months postablation, defined as a documented (>30 seconds) episode of AF, flutter, or a…
Mortality after cardioverter-defibrillator replacement: Results of the DECODE survival score index
2020
Background Device replacement is the ideal time to reassess health care goals regarding continuing implantable cardioverter-defibrillator (ICD) therapy. Only few data are available on the decision making at this time. Objectives The goals of this study were to identify factors associated with poor prognosis at the time of ICD replacement and to develop a prognostic index able to stratify those patients at risk of dying early. Methods DEtect long-term COmplications after implantable cardioverter-DEfibrillator replacement (DECODE) was a prospective, single-arm, multicenter cohort study aimed at estimating long-term complications in a large population of patients who underwent ICD/cardiac resy…
Prognostic Role of Late Gadolinium Enhancement in Patients With Hypertrophic Cardiomyopathy and Low-to-Intermediate Sudden Cardiac Death Risk Score
2019
Sudden cardiac death (SCD) is the most life-threating complication of hypertrophic cardiomyopathy. Guidelines of the European Society of Cardiology (ESC) suggest the implantation of an implantable cardioverter defibrillator in primary prevention according to a 5-year risk SCD score >= 6%. The aim of the study is to evaluate the prognostic role of late gadolinium enhancement (LGE) in patients with a 5-year risk SCD score <6%. In this multicenter study, we performed cardiac magnetic resonance in 354 consecutive hypertrophic cardiomy-opathy patients (257 males, range of age 54 +/- 17) with a risk SCD score <6% (302 with <4% and 52 with >= 4 and <6% risk). Hard cardiac events,…
Recommendations of the European Cardiac Arrhythmia Society Committee on Device Failures and Complications
2006
Recommendations of the European Cardiac Arrhythmia Society Committee on Device Failures and Complications MASSIMO SANTINI,* JOHANNES BRACHMANN,† RICCARDO CAPPATO,‡ WYN DAVIES,§ JERONIMO FARRE,‖ SAMUEL LEVY,¶ AURELIO QUESADA,# RENATO P. RICCI,** EDWARD ROWLAND,†† NEIL SULKE‡‡ From *San Filipo Neri Hospital, Rome, Italy, †Klinikum Coburg, Germany, ‡Policlinico S. Donato, Milan, Italy, §St. Mary Hospital, London, UK, ‖Fundacion Jimenez Diaz, Madrid, Spain, ¶Hopital Nord des Bourrellys, Marseille, France, #Hospital General University of Valencia, Spain, **San Filippo Neri Hospital, ††St. George Medical School, London, UK, ‡‡Eastbourne General Hospital, Sussex, UK
Reduction of ICD Shock Burden by Eliminating Back-Up Pacing Induced Ventricular Tachyarrhythmias
2014
ICD Shock Reduction by Subthreshold Pacing Introduction Implantable cardioverter defibrillators (ICD) may have the capacity to provoke or worsen ventricular tachyarrhythmias (VT). It has been reported that ICD shocks by itself can increase mortality. This study aimed to determine the role of back-up pacing-induced VT (PIT) in the overall ICD shock burden by avoiding pause-related ventricular back-up pacing. Methods and Results A population of 550 single-chamber ICD patients was studied. Of them, 17 (3%, 69 ± 16 years, 14 male) patients had documented episodes of PIT. A total of 431 VT episodes were documented including 89 (21%) due to PIT. In 3 patients, VT events were exclusively PITs. Aft…
Feasibility of Implantable Cardioverter Defibrillator Treatment in Five Patients With Familial Friedreich's Ataxia-A Case Series
2010
Friedreich's ataxia (FRA) is an autosomal recessive disease of the central nervous system that is associated with familial cardiomyopathy. Cardiac involvement is seen in more than 90% of the patients and is the most common cause of death in these patients. We present a case series and discuss the indications for implantable cardioverter defibrillator (ICD) implantation in FRA with review of the literature. Five pediatric patients who suffer from FRA (four female and one male, mean age 17.4 years) underwent ICD implantation between 2007 and 2008 in the University Hospital of Goettingen. The diagnosis of FRA was established by standard clinical criteria and proven in each case by genotyping a…
In-hospital and long-term prognosis in patients after implantation of implantable cardioverter-defibrillators and cardiac resynchronization therapy: …
2018
Introduction During the last 20 years, there has been a considerable increase in the number of implanted implantable cardioverter‑defibrillator (ICD) and cardiac resynchronization therapy (CRT) devices. However, there have been only single reports on clinical events, including rehospitalizations, in the long‑term follow‑up. Objectives We analyzed the baseline clinical characteristics, medical procedures used, and complications of patients with implantation of an ICD or CRT device. Moreover, we analyzed the causes of rehospitalization and the types of treatment used in the 12‑month follow‑up. Patients and methods Out of 1 208 440 hospitalizations of patients with cardiovascular diseases incl…