Search results for "Defibrillators"
showing 10 items of 25 documents
Optimal Response to Cardiac Arrest study: Defibrillation waveform effects
2001
Abstract Introduction: Advances in early defibrillation access, key to the “Chain of Survival”, will depend on innovations in defibrillation waveforms, because of their impact on device size and weight. This study compared standard monophasic waveform automatic external defibrillators (AEDs) to an innovative biphasic waveform AED. Material and methods: Impedance-compensated biphasic truncated exponential (ICBTE) and either monophasic truncated exponential (MTE) or monophasic damped sine (MDS) AEDs were prospectively, randomly assigned by date in four emergency medical services. The study design compared ICBTE with MTE and MDS combined. This subset analysis distinguishes between the two clas…
How to evaluate first aid skills after training: a systematic review
2022
Abstract Background To be able to help and save lives, laypersons are recommended to undergo first aid trainings. The aim of this review was to explore the variety of the elements of the measuring systems to assess the effects of first aid trainings on different aspects of first aid skills including practical skills, knowledge, and emotional perspectives. Methods This systematic literature review used Scopus and PubMed databases and searched for studies published between January, 2000, and December, 2020. Out of 2,162 studies meeting the search criteria, 15 studies with quantitative and repeatable evaluation methods to assess first aid skills after first aid training for adults were include…
Cardiovascular outcomes after cardiac resynchronization therapy in cardiac amyloidosis
2021
Abstract Aims Cardiac resynchronization therapy (CRT) is highly effective in dilated cardiomyopathy (DCM) patients with impaired left ventricular ejection fraction (LVEF) and left bundle block branch. In cardiac amyloidosis (CA) patients, left ventricular dysfunction and conduction defects are common, but the potential of CRT to improve cardiac remodelling and survival in this particular setting remains undefined. We investigated cardiovascular outcomes in CA patients after CRT implantation in terms of CRT echocardiographic response and major cardiovascular events (MACEs). Methods and results Our retrospective study included 47 CA patients implanted with CRT devices from January 2012 to Feb…
European Clinical Experience with a Dual Chamber Single Pass Sensing and Pacing Defibrillation Lead
2002
Dual chamber ICDs are increasingly implanted nowadays, mainly to improve discrimination between supraventricular and ventricular arrhythmias but also to maintain AV synchrony in patients with bradycardia. The aim of this study was to investigate a new single pass right ventricular defibrillation lead capable of true bipolar sensing and pacing in the right atrium and integrated bipolar sensing and pacing in the right ventricle. The performance of the lead was evaluated in 57 patients (age 61 +/- 12 years; New York Heart Association 1.9 +/- 0.6, left ventricular ejection fraction 0.38 +/- 0.15) at implant, at prehospital discharge, and during a 1-year follow-up. Sensing and pacing behavior of…
Managed ventricular pacing vs. conventional dual-chamber pacing for elective replacements: the PreFER MVP study: clinical background, rationale, and …
2008
Udgivelsesdato: 2008-Mar AIMS: Several clinical studies have shown that, in patients with intact atrioventricular (AV) conduction, unnecessary chronic right ventricular (RV) pacing can be detrimental. The managed ventricular pacing (MVP) algorithm is designed to give preference to spontaneous AV conduction, thus minimizing RV pacing. The clinical outcomes of MVP are being studied in several ongoing trials in patients undergoing a first device implantation, but it is unknown to what extent MVP is beneficial in patients with a history of ventricular pacing. The purpose of the Prefer for Elective Replacement MVP (PreFER MVP) study is to assess the superiority of the MVP algorithm to convention…
Focus on right ventricular outflow tract septal pacing
2013
SummaryExperimental and clinical studies have shown that right ventricular apical pacing may result in long-term deleterious effects on account of its negative impact on left ventricular remodeling through desynchronization. This risk appears more pronounced in patients with even moderate left ventricular dysfunction and generally occurs after at least 1 year of pacing. As right ventricular apical pacing may be associated with the development of organic mitral insufficiency, other sites that allow for more physiological stimulation, such as right ventricular outflow tract septal pacing, have been developed, with good feasibility and reproducibility. However, the prospective randomized studi…
Natural history of the Sprint Fidelis lead: survival analysis from a large single-center study.
2012
The purposes of our study were to: (1) determine lead failure rate in a large single-center cohort of Sprint Fidelis 6949 (Fidelis) leads, (2) define the risk of lead failure over time, (3) assess the impact of the Lead Integrity Alert (LIA) on lead failure presentation, and (4) identify independent predictors of Fidelis lead failure. All patients who underwent implantation of a Fidelis lead between September 2004 and July 2007 were included. Demographic, clinical, and device characteristics at the time of implant and prior to failure were collected and analyzed. A total of 971 Fidelis leads (706 men, 265 women, mean age 68.4 ± 12.8 years) were implanted. Over a mean follow-up of 46.3 month…
Mortality after cardioverter-defibrillator replacement: Results of the DECODE survival score index
2020
Background Device replacement is the ideal time to reassess health care goals regarding continuing implantable cardioverter-defibrillator (ICD) therapy. Only few data are available on the decision making at this time. Objectives The goals of this study were to identify factors associated with poor prognosis at the time of ICD replacement and to develop a prognostic index able to stratify those patients at risk of dying early. Methods DEtect long-term COmplications after implantable cardioverter-DEfibrillator replacement (DECODE) was a prospective, single-arm, multicenter cohort study aimed at estimating long-term complications in a large population of patients who underwent ICD/cardiac resy…
ICD Implantation in infants and small children: the extracardiac technique.
2007
There is no clear methodology for implantation of an internal cardioverter-defibrillator (ICD) in infants and small children. The aim of this study was to assess efficacy and safety of an extracardiac ICD implantation technique in pediatric patients.An extracardiac ICD system was implanted in eight patients (age: 0.3-8 years; body weight: 4-29 kg). Under fluoroscopic guidance a defibrillator lead was tunneled subcutaneously starting from the anterior axillar line along the course of the 6th rib until almost reaching the vertebral column. After a partial inferior sternotomy, bipolar steroid-eluting sensing and pacing leads were sutured to the atrial wall (n = 2) and to the anterior wall of t…
Cardiac arrhythmias in patients with Danon disease.
2016
Aims Different cardiac arrhythmias have been suggested to be associated with Danon disease, e.g. Wolff–Parkinson–White syndrome. However, a systematic electrophysiological investigation of patients with Danon disease is lacking thus far. Methods and results Seven patients with Danon disease (4 males, 35.8 ± 10.8 years; 3 females, 51.3 ± 19.9 years) from 3 different families were studied. In all patients, the presence of Danon disease was confirmed by western blot of biopsy material or genetic testing. The patients were characterized by 12-lead electrocardiogram (ECG), Holter ECG, echocardiography, and serial implantable cardioverter defibrillator (ICD) interrogations (in ICD recipients). Al…