Mechanical behavior of provisional implant prosthetic abutments
2014
Introduction: Implant-supported prostheses have to overcome a major difficulty presented by the morphology and esthetics of peri-implant tissues in the anterior sector. Diverse therapeutic techniques are used for managing the mucosa adjacent to the implant and the most noteworthy is immediate/deferred fixed provisionalization. Objectives: In vitro testing of strength and deformation of implant prosthetic abutments made from different materials (Titanium/PEEK/methacrylate). Material and Methods: Forty Sweden&Martina® implant prosthetic abutments (n=40) were divided into five groups: Group MP: methacrylate provisional abutments with machined titanium base; Group PP: Poly ether ether ketone (P…
Development and viability of biofilms grown on experimental abutments mimicking dental implants: an in vivo model
2019
Background To determine whether an experimental abutment mimicking the macro- and microstructure of a dental implant is a suitable method for recovering biofilm, and to describe the features of biofilms formed around such abutments on healthy implants. Material and Methods Experimental abutments were used in 15 patients without peri-implant diseases. After 14 days’ absence of dental hygiene in this area, the abutments were retrieved and analyzed through confocal laser scanning microscopy and scanning electron microscopy. The biofilm formation on the surface of the first 5 abutments was determined by a fluorescence-staining method using SYTO9 nucleic acid stain. In order to study the biofilm…
Effects of various hygiene procedures on the surface characteristics of titanium abutments.
1996
The use of cleaning instruments on titanium implants may cause undesired surface alterations. In a qualitative and quantitative assessment of these alterations, 5 titanium implant abutments were treated with a steel curet, a prototype pure titanium curet, an air abrasive polishing system, and an ultrasonic system. Custom-made polymer templates, used to secure the curet to a vertical guide bar and a spring scale to maintain a constant instrument pressure, guaranteed a standardized procedure and reproducible results. The ultrasonic and the air abrasive polishing method were also standardized. Evaluation by scanning electron microscopy (SEM) revealed surface alterations for all instruments and…
Culturomic and quantitative real‐time ‐ polymerase chain reaction analyses for early contamination of abutments with different surfaces: A randomized…
2021
Background Rough and/or plasma-activated abutments seem to be able to increase soft tissue adhesion and stability; however, limited evidence is available about bacterial contamination differences. Purpose The aim was to investigate the oral microbiota on four dental abutments with different surfaces by quantitative real-time polymerase chain reaction (qRT-PCR) and culturomic approach. Methods Forty patients needing a single implant rehabilitation were involved in the study. Forty healing abutments, especially designed for the study, were divided into four groups according to the surface topography (1. machined [MAC], 2. machined plasma of argon treated [plasmaMAC], 3. ultrathin threaded mic…
Soft tissue integration of different abutment surfaces: An experimental study with histological analysis
2021
OBJECTIVE To evaluate whether abutment surface and surface bio-activation have an effect on soft tissue morphogenesis. MATERIALS AND METHODS 36 patients (36 implants) were included. Abutments were randomly divided into 4 groups (n = 9): Smooth Surface-MAChined (MAC), Ultrathin Threaded Microsurface (UTM), MAC Plasma of Argon activated (Plasma-MAC), and UTM Plasma of Argon activated (Plasma-UTM). After 2 months of healing, soft tissue samples were collected and prepared for histological analysis. The margin of the peri-implant mucosa (PM), the apical extension of the barrier epithelium (aJE), and the apical location of the abutment (AM) were identified. Significances of differences among gro…
Preliminary study about the efficiency of diode laser compared with retraction cords used for exposing the finishing lines of dental abutments before…
2016
Is the re-use of sterilized implant abutments safe enough? (Implant abutment safety)
2019
Background: The reuse of implant healing abutments is common in dental practice. Effective elimination of bacteria and viruses is accomplished by conventional sterilization. The aim of this work was to explore the eventual survival of microorganisms on sterilized healing abutments and to rule out the presence of transmissible organic material after standard procedures. Material and Methods: A total of 55 healing abutments previously used in patients will be washed and sterilized in a steam autoclave at 121oC for 15 min. Each healing abutment will be cultured in Brain Heart Infusion broth (BHI) under strict aseptic conditions. Besides, two control groups will be included: one of 3 unused hea…
Definitive Abutments Placed at Implant Insertion and Never Removed: Is It an Effective Approach? A Systematic Review and Meta-Analysis of Randomized …
2017
Purpose To assess whether repeated abutment disconnections and reconnections have any impact on peri-implant bone resorption and soft tissue healing. Materials and Methods Electronic and manual searches were conducted for English-language articles published up to March 2017 that identified a relation between repeated disconnections of implant abutments (PA group) and prosthetic or implant failures, complications, marginal bone loss (MBL), soft tissue healing, and esthetic evaluation (pink esthetic score [PES]) after at least 1 year of function compared with implants receiving a final abutment at the time of implant placement (DA group). Results Fourteen articles (535 patients with 994 impla…