Search results for "Dental Implants"

showing 10 items of 281 documents

Oral microcirculation observed in vivo by videocapillaroscopy: a review

2009

Capillaroscopy is a non-invasive diagnostic technique that is fundamental in viewing peripheral circulation and in studying microangiopathies. The morphological study of microcirculat ion is of fundamental importance, mainly because the microvascular bed is directly involved in the etiopathogenesis of autoimmune disorders and acute and chronic inflammatory pathological conditions. The value of capillaroscopic investigation as a diagnostic means in cases of peripheral microcirculation disorders has been confirmed by numerous studies. Other studies used capillaroscopic investigations to evaluate microcirculation damage not as a complication of disease (diabetes), but as its initial stage, and…

Dental ImplantsPathologymedicine.medical_specialtyMicroscopy Videobusiness.industryMouth MucosaBurning Mouth SyndromeAutoimmune DiseasesMicroscopic AngioscopyMicrocirculationMicrovascular Bedmedicine.anatomical_structureIn vivoPeripheral microcirculationMicrovesselsImage Processing Computer-AssistedHumansMedicineOral mucosaMouth DiseasesbusinessGeneral Dentistryoral capillaroscopy microcirculationJournal of Oral Science
researchProduct

Oral rehabilitation with tilted dental implants: A metaanalysis

2012

Objective: To compare the course of patients treated with tilted implants versus those treated conventionally with axial implants, analyzing the success rate and marginal bone loss. Material and M ethods: A PubMed search was made using the key words ?tilted implants?, ?angled implants?, ?angulated implants?, ?inclined implants? and ?maxillary atrophy.? A review was made of the articles published between 1999-2010. The inclusion criteria were the use of tilted implants, clinical series involving at least 10 patients, and a minimum follow-up of 12 months after prosthetic loading. The exclusion criteria were isolated clinical cases, studies with missing data, and publications in languages othe…

Dental ImplantsRehabilitationbusiness.industrymedicine.medical_treatmentReview-ArticleAlveolar Bone LossDentistryRetrospective cohort study:CIENCIAS MÉDICAS [UNESCO]Dental ImplantationOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASMedicineHumansSurgeryOral SurgerybusinessProspective cohort studyGeneral DentistryMedicina Oral, Patología Oral y Cirugía Bucal
researchProduct

Marginal bone loss in relation to the implant neck surface: An update

2010

A review is made of the publications on the marginal bone loss of implants with a polished neck, rough neck with microthreading, and rough neck without microthreading. A PubMed search was carried out with the following key words: machined neck implant, polished neck implant, marginal bone loss, covering the period between January 1998 and March 2009. Inclusion was limited to those human clinical studies involving a minimum follow-up of 12 months, and registering the level of bone loss from the time of placement of the implant or prosthetic restoration to the end of follow-up. For most of the authors there were no significant differences in marginal bone loss between polished neck and rough …

Dental ImplantsSurface Propertiesbusiness.industryAlveolar Bone LossDentistryNeck surfaceOtorhinolaryngologyHumansMedicineSurgeryImplantbusinessGeneral DentistrySurvival rateMedicina Oral Patología Oral y Cirugia Bucal
researchProduct

Risk factors associated with early failure of dental implants. A literature review

2010

The aim of the study was to examine articles published on risk factors associated with early failure of dental implants. We conducted a search on PubMed for articles published between January 2000 and December 2009 using the keywords 'dental implants' and 'early failure'. Seven studies that specified the number of early failed implants and studied the associated risk factors were included. Early failures are caused by the inability of tissue to establish osseointegration prior to prosthetic restoration; however the causal factors and mechanisms are unclear. In the reviewed literature there was a higher percentage of early than late failures; nevertheless, few articles were found that analyz…

Dental ImplantsTime Factorsbusiness.industryDentistryImplant failureOsseointegrationOtorhinolaryngologyRisk FactorsUNESCO::CIENCIAS MÉDICASMedicineHumansSurgeryImplantDental Restoration FailurebusinessEarly failureGeneral Dentistry
researchProduct

Customised products for orbital wall reconstruction: a systematic review

2021

Abstract The purpose of this systematic review was to critically analyze the recent literature to present the state of the art in customized reconstruction of orbital fractures. Three electronic databases and manual search approaches were used to identify relevant articles. Only studies with a controlled clinical study design were included. Primary outcome was defined as the status of recovery (complete/partial functional and esthetic disturbances). The benefit of intra-surgical navigation should be described. Secondary outcome was defined as the time of surgery, post-surgical events and hospitalization. A total of eight studies out of 552 records identified met the inclusion criteria. Post…

Dental ImplantsTitaniumOrbital wallNavigated surgerymedicine.medical_specialtybusiness.industryClinical study designPlastic Surgery ProceduresSurgical MeshPrimary outcomeSecondary outcomeSurgery Computer-AssistedOtorhinolaryngologyHumansMedicineSurgeryMedical physicsOral SurgerybusinessOrbitOrbital FracturesBritish Journal of Oral and Maxillofacial Surgery
researchProduct

Effects of a local single dose administration of growth hormone on the osseointegration of titanium implants.

2021

The aim of the present study was to evaluate the effect of different concentrations of growth hormone (GH) on endosteal implant?s surface at the early stages of osseointegration. Sixty tapered acid-etched titanium implants were divided into four groups: i) Collagen, used as a control group; and three experimental groups, where after collagen coating, GH was administered directly to the surface in varying concentrations: ii) 0.265 mg, iii) 0.53 mg, and iv) 1 mg. Implants were placed in an interpolated fashion in the anterior flange of C3, C4 or C5 of 15 sheep with minimum distance of 6 mm between implants. After 3-, 6- and 12-weeks of healing samples were harvested, histologically processed,…

Dental ImplantsTitaniumSheepSurface Propertiescortical graftaugmentation procedureonlay graftintraoral boneOtorhinolaryngologyOsseointegrationGrowth HormoneAnimalsSurgeryGeneral DentistryUNESCO:CIENCIAS MÉDICASMedicina oral, patologia oral y cirugia bucal
researchProduct

Patient‐specific titanium meshes: Future trend or current technology?

2021

Dental ImplantsTitaniumTechnologyInformation retrievalComputer scienceMEDLINEFuture trendchemistry.chemical_elementSurgical MeshPatient specificSurgical meshchemistryHumansPolygon meshCurrent technologyOral SurgeryGeneral DentistryTitaniumClinical Implant Dentistry and Related Research
researchProduct

Topographic characterisation of dental implants for commercial use.

2016

Background To characterize the surface topography of several dental implants for commercial use. Material and Methods Dental implants analyzed were Certain (Biomet 3i), Tissue Level (Straumann), Interna (BTI), MG-InHex (MozoGrau), SPI (Alphabio) and Hikelt (Bioner). Surface topography was ascertained using a confocal microscope with white light. Roughness parameters obtained were: Ra, Rq, Rv, Rp, Rt, Rsk and Rku. The results were analysed using single-factor ANOVA and Student-Neuman-Keuls(p<0.05) tests. Results Certain and Hikelt obtained the highest Ra and Rq scores, followed by Tissue Level. Interna and SPI obtained lower scores, and MG-InHex obtained the lowest score. Rv scores followed …

Dental ImplantsTitaniumbusiness.industrySurface PropertiesResearchDentistryTissue level030206 dentistry02 engineering and technology:CIENCIAS MÉDICAS [UNESCO]021001 nanoscience & nanotechnology03 medical and health sciences0302 clinical medicineOtorhinolaryngologyDental Prosthesis DesignUNESCO::CIENCIAS MÉDICASWhite lightHumansSurgeryImplantOral Surgery0210 nano-technologybusinessGeneral DentistryMathematicsMedicina oral, patologia oral y cirugia bucal
researchProduct

A Prospective Noninterventional Study to Evaluate Survival and Success of Reduced Diameter Implants Made From Titanium-Zirconium Alloy

2015

Narrow diameter implants may be at increased risk of overload due to occlusal forces; therefore, implants with higher fatigue strength may be beneficial. The aim of this observational study was to evaluate survival and success of narrow diameter (Ø 3.3 mm) TiZr alloy (Roxolid, Institut Straumann AG, Basel, Switzerland) implants for 2 years in daily dental practice. This was a prospective, non-interventional, multicenter study; no specific patient inclusion or exclusion criteria were applied. Each patient received at least one TiZr implant; the treatment plan, including implant loading and final restoration, was at the investigator's discretion. The primary outcome was implant survival and s…

Dental ImplantsTitaniummedicine.medical_specialtybusiness.industryDental Implantation EndosseousCumulative survivalTitanium zirconiumSurgeryTreatment OutcomePrimary outcomeIncreased riskDental Prosthesis DesignMulticenter studyTreatment planAlloysHumansMedicineDental Restoration FailureProspective StudiesZirconiumImplant loadingImplantOral SurgerybusinessFollow-Up StudiesJournal of Oral Implantology
researchProduct

Three-dimensional scanning electron microscopy of maxillofacial biomaterials

2017

Dental Implantsbusiness.industryScanning electron microscopeOral Surgical Procedures010401 analytical chemistryBiocompatible Materials030206 dentistry01 natural sciences0104 chemical scienceslaw.invention03 medical and health sciencesImaging Three-Dimensional0302 clinical medicineOtorhinolaryngologylawMicroscopy Electron ScanningMedicineSurgeryOral SurgeryElectron microscopebusinessThree dimensional scanningBiomedical engineeringBritish Journal of Oral and Maxillofacial Surgery
researchProduct