Osseointegration of one-piece zirconia implants compared with a titanium implant of identical design: a histomorphometric study in the dog

2010

Objective: The aim of this study was to evaluate osseointegration of one-piece zirconia vs. titanium implants depending on their insertion depth by histomorphometry. Material and methods: Four one-piece implants of identical geometry were inserted on each side of six mongrel dogs: (1) an uncoated zirconia implant, (2) a zirconia implant coated with a calcium-liberating titanium oxide coating, (3) a titanium implant and (4) an experimental implant made of a synthetic material (polyetheretherketone). In a split-mouth manner they were inserted in submerged and non-submerged gingival healing modes. After 4 months, dissected blocks were stained with toluidine blue in order to histologically asse…

Materials scienceAlveolar Bone Losschemistry.chemical_elementDentistryInsertion depthOsseointegrationDogsCoated Materials BiocompatibleImplants ExperimentalOsseointegrationAnimalsCubic zirconiaDental ImplantsTitaniumMaterial typebusiness.industryDental Implantation EndosseousTitanium oxideDental Prosthesis DesignchemistryZirconiumImplantOral SurgerybusinessTitaniumA titaniumClinical Oral Implants Research
researchProduct

Repeatability of the resonance frequency analysis values in implants with a new technology

2019

Background Assess the reliability (by means of reproducibility and repeatability) of the PenguinRFA system, analyse the ISQ values of different implant types and correlate the ISQ with the insertion torque during the placement of the implant. Material and Methods 120 rough surface implants were placed in bovine bone (type II and III). The implants were divided into groups, according to its design. Once the implants were in place, the exact insertion torque was registered. Then, primary stability was measured by means of the resonance frequency analysis with the PenguinRFA and the Osstell ISQ devices. In each implant two transducers of each device were used. Three measurements were obtained …

Materials scienceIntraclass correlationVibrationDental Prosthesis Retention03 medical and health sciences0302 clinical medicineAnimalsGeneral DentistryDental ImplantsReproducibilityResearchDental Implantation EndosseousResonance Frequency AnalysisReproducibility of Results030206 dentistryRepeatability:CIENCIAS MÉDICAS [UNESCO]Implant stability quotientResonance frequency analysisDental Prosthesis DesignTorqueOtorhinolaryngologyRough surfaceUNESCO::CIENCIAS MÉDICASImplant typesCattleSurgeryImplantOral SurgeryBiomedical engineeringMedicina Oral Patología Oral y Cirugia Bucal
researchProduct

Relation between bone quality values from ultrasound transmission velocity and implant stability parameters--an ex vivo study.

2011

Aim The objective of this study was to determine the relationship between bone qualities measured by ultrasound transmission velocity (UTV) and primary implant stability parameters measured by radiofrequency analysis (RFA) and push-out test (POT) in an ex-vivo model. Materials and methods Three blocks of fresh porcine bone samples were obtained from different anatomic regions, correlating to cortical, mixed and cancellous bone. Mechanical bone qualities of these samples were measured using UTV (expressed in m/s) prior to implantation. Three similar implants (4.1 × 11 mm, AstraTech OS) were inserted into each of the procured bone blocks. The evaluation of implant-bone interface stability was…

Materials scienceRadio WavesSwineDentistryIn Vitro TechniquesDental Prosthesis RetentionIliumImplants ExperimentalPorcine boneBone qualitymedicineAnimalsUltrasonographyDental ImplantsTibiabusiness.industryUltrasoundDental Implantation EndosseousImplant stability quotientmedicine.anatomical_structureModels AnimalImplantOral SurgerybusinessCancellous boneEx vivoBiomedical engineeringClinical oral implants research
researchProduct

The role of angiogenesis in implant dentistry part I: Review of titanium alloys, surface characteristics and treatments

2015

Background: Angiogenesis plays an important role in osseointegration process by contributing to inflammatory and regenerative phases of surrounding alveolar bone. The present review evaluated the effect of titanium alloys and their surface characteristics including: surface topography (macro, micro, and nano), surface wettability/ energy, surface hydrophilicity or hydrophobicity, surface charge, and surface treatments of dental implants on angiogenesis events, which occur during osseointegration period. Material and Methods: An electronic search was performed in PubMed, MEDLINE, and EMBASE databases via OVID using the keywords mentioned in the PubMed and MeSH headings regarding the role of …

Materials scienceSurface PropertiesAngiogenesismedicine.medical_treatmentNeovascularization PhysiologicDentistrychemistry.chemical_elementOdontologíaReview02 engineering and technologyOsseointegrationNeovascularization03 medical and health sciences0302 clinical medicineOsseointegrationAlloysmedicineDental Prosthesis DesignHumansDental implantGeneral DentistryDental alveolusDental ImplantsTitaniumbusiness.industry030206 dentistry:CIENCIAS MÉDICAS [UNESCO]021001 nanoscience & nanotechnologyCiencias de la salud3. Good healthstomatognathic diseasesDental Prosthesis DesignOtorhinolaryngologychemistryUNESCO::CIENCIAS MÉDICASSurface modificationSurgeryOral Surgerymedicine.symptom0210 nano-technologybusinessTitaniumMedicina Oral Patología Oral y Cirugia Bucal
researchProduct

Vertical osteoconductivity and early bone formation of titanium-zirconium and titanium implants in a subperiosteal rabbit animal model.

2013

Objectives The aim of this pilot study was to evaluate the vertical osteoconductive and osteointegrative dynamics around titanium–zirconium (TiZr) implants compared to titanium (Ti) implants. Materials and methods In a split-leg design, 12 TiZr-SLActive and 12 Ti-SLActive implants were inserted 3 mm above bone level in the proximal tibia of 12 rabbits. Full periosteal flaps were repositioned to cover the site. Specimens were obtained after 10, 20 and 30 days (each n = 4 per group). Histomorphometric measurements included percentage of linear bone fill (PLF; %), new marginal vertical bone height (VBH; mm) and vertical bone-to-implant contact (vBIC; %). Statistical analysis was performed with…

Materials scienceSurface PropertiesDentistrychemistry.chemical_elementPilot ProjectsSurgical FlapsProximal tibiaAnimal modelOsteogenesisAnimalsStatistical analysisBone formationBone levelBone heightDental ImplantsTitaniumTibiabusiness.industryDental Implantation EndosseousTitanium zirconiumchemistryDental Prosthesis DesignModels AnimalRabbitsZirconiumOral SurgerybusinessBone ConductionTitaniumClinical oral implants research
researchProduct

Soft Tissue Healing at One-Piece Zirconia Implants Compared to Titanium and PEEK Implants of Identical Design: A Histomorphometric Study in the Dog

2013

This study aimed to histomorphometrically evaluate the soft tissue reactions of one-piece zirconia implants versus titanium implants in regard to their insertion depth. Four one-piece implants of identical geometry were inserted on each side of six mongrel dogs: an uncoated zirconia implant, a zirconia implant coated with a calcium liberating titanium oxide, a titanium implant, and an experimental implant made of a synthetic material. Using a split-mouth design, they were inserted in both submerged and nonsubmerged healing modes. After 4 months, dissected blocks were stained with toluidine blue to histologically assess the marginal portion of the implant mucosa, apical extension of the barr…

Materials sciencechemistry.chemical_elementDentistryConnective tissueOsseointegrationDogsCoated Materials BiocompatibleImplants ExperimentalOsseointegrationPeekmedicineAnimalsCubic zirconiaDental ImplantsTitaniumWound Healingbusiness.industryDental Implantation EndosseousSoft tissuemedicine.anatomical_structureDental Prosthesis DesignchemistryPeriodonticsZirconiumImplantOral SurgeryWound healingbusinessTitaniumInternational Journal of Periodontics and Restorative Dentistry
researchProduct

Improving PMMA resin using graphene oxide for a definitive prosthodontic rehabilitation - A clinical report

2019

The use of acrylic resins as a definitive material has shown some advantages comparing to other definitive materials. However, their poor mechanical properties remain a major drawback. In this case report, graphene oxide (GO) was incorporated into polymethyl methacrylate (PMMA) resin for a definitive maxillary rehabilitation, combined with an intraoral digital impression and a three-dimensional facial scan. After 8 months of the placement of the definitive prosthesis, no mechanical, aesthetic, or biologic complications were reported, and the soft tissues showed excellent health and stability. The incorporation of GO in PMMA resins seems to be a suitable option for prosthetic rehabilitation.…

Materials sciencemedicine.medical_treatmentOxideDentistryCase ReportProsthesislaw.invention03 medical and health scienceschemistry.chemical_compound0302 clinical medicineClinical reportlawmedicineDental Impression TechniqueGeneral DentistryAcrylic resin030304 developmental biologyProsthetic Dentistry0303 health sciencesbusiness.industryGrapheneDental prosthesistechnology industry and agriculture030206 dentistry:CIENCIAS MÉDICAS [UNESCO]Impressionchemistryvisual_artUNESCO::CIENCIAS MÉDICASvisual_art.visual_art_mediumbusinessJournal of Clinical and Experimental Dentistry
researchProduct

Rehabilitation of atrophic maxilla: a review of 101 zygomatic implants

2008

Introduction: Zygomatic implants are a good rehabilitation alternative for upper maxilla with severe bone reabsorption. These implants reduce the need for onlay-type bone grafting in the posterior sectors and for maxillary sinus lift procedures - limiting the use of bone grafts to the anterior zone of the upper jaw in those cases where grafting is considered necessary. Objective: To evaluate the survival of 101 zygomatic implants placed in upper maxilla presenting important bone reabsorption, with a follow-up of 1-72 months. Patients and methods: A retrospective study was made of 101 Zygoma® implants (Nobel Biocare, Göteborg, Sweden) placed in 54 patients with totally edentulous and atrophi…

Maxil·larsImplants dentalsDental prosthesisUNESCO::CIENCIAS MÉDICASDental implantsJaws:CIENCIAS MÉDICAS [UNESCO]Pròtesis dentals
researchProduct

The implant-supported milled bar overdenture : a literature review

2008

Purpose: This bibliographical review aims to determine the present situation of the implant-supported milled bar overdenture as a therapeutic option in implantology, as well as to set and compare the techniques and materials currently used for making them. Materials and methods: By searching the main electronic bibliographical data in indexed Medline articles, we obtained a total number of 20 articles that fulfilled the requirements of this bibliographical review. Results: The implant-supported milled bar overdenture offers excellent long-term successful results, although complication rates are higher in emergency cases of patients initially planned for a fixed prosthesis. Krenmair and coll…

Moderate to severeFixed prosthesisbusiness.industryBar (music)DentistryCumulative survivalDenture Overlay:CIENCIAS MÉDICAS [UNESCO]OtorhinolaryngologyDental Prosthesis DesignMaxillaUNESCO::CIENCIAS MÉDICASDental Prosthesis DesignMedicineHumansSurgerybusinessGeneral DentistryImplant supported
researchProduct

Peri-implant defect grafting with autogenous bone or bone graft material in immediate implant placement in molar extraction sites-1- to 3-year result…

2020

Objectives To evaluate the survival rate, the orobuccal bone resorption and stability of peri-implant hard and soft tissues following immediate implant placement of wide diameter implants in molar extraction sites and peri-implant defect grafting with autogenous bone (AB) or biphasic bone graft material (BBGM) with 1- to 3-year follow-up examinations. Material and methods Fifty wide diameter implants were placed in 50 patients immediately into molar extraction sockets by a flapless approach. Peri-implant defect augmentation was performed randomized with either AB or BBGM. Primary outcome variable was implant survival. Marginal bone level changes, orobuccal width of the alveolar crest, probi…

Molar0206 medical engineeringAlveolar Bone LossDentistryTransplants02 engineering and technologyBone resorption03 medical and health sciences0302 clinical medicineDental Implants Single-ToothMedicineHumansProspective StudiesTooth SocketSurvival rateDental ImplantsBone Transplantationbusiness.industryExtraction (chemistry)Soft tissue030206 dentistryGrafting020601 biomedical engineeringMolarResorptionTreatment OutcomeDental Prosthesis DesignTooth ExtractionImplantOral SurgerybusinessFollow-Up StudiesClinical oral implants researchREFERENCES