Search results for "Dental Stress Analysis"

showing 9 items of 29 documents

Luting of ceramic crowns with a self-adhesive cement: Effect of contamination on marginal adaptation and fracture strength

2012

Objectives: This study evaluated the percentages of continuous margins (%CM) and fracture strength (FS) of crowns made out from blocs of leucite-reinforced ceramic (IPS Empress CAD) and luted with a representative self-adhesive cement (RelyX Unicem) under four contaminating agents: saliva, water, blood, a haemostatic solution containing aluminium chloride (pH= 0.8) and a control group with no contamination. Study Design: %CM at both tooth-cement (TC) and cement-crown (CC) interfaces were determined before and after a fatigue test consisting of 600’000 chewing loads and 1’500 temperature cycles changing from 5º C to 50º C. Load to fracture was recorded on fatigued specimens. Kruskal-Wallis t…

Dental Stress AnalysisSalivaAluminium chlorideDental CementsDentistryOdontologíaIn Vitro TechniquesDental porcelainFlexural strengthDental cementBiomaterials and Bioengineering in DentistryDentinmedicineHumansGeneral DentistryCementCrownsChemistrybusiness.industryContamination:CIENCIAS MÉDICAS [UNESCO]Dental PorcelainCiencias de la saludddc:617.6Resin Cementsmedicine.anatomical_structureOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASResearch-ArticleSurgerybusinessmedicine.drugMedicina Oral Patología Oral y Cirugia Bucal
researchProduct

Fracture resistance after implantoplasty in three implant-abutment connection designs

2020

Background To assess the effect of implantoplasty and implant-abutment design on the fracture resistance and macroscopic morphology of narrow-diameter (3.5 mm) dental implants. Material and Methods Screw-shaped titanium dental implants (n = 48) were studied in vitro. Three groups (n = 16) were established, based on implant-abutment connection type: external hexagon, internal hexagon and conical. Eight implants from each group were subjected to an implantoplasty procedure; the remaining 8 implants served as controls. Implant wall thickness was recorded. All samples were subjected to a static strength test. Results The mean wall thickness reductions varied between 106.46 and 153.75 µm. The me…

Dental Stress AnalysisTitanium implantMaterials scienceCirurgia dentalchemistry.chemical_elementDental Abutments03 medical and health sciences0302 clinical medicineFlexural strengthDental AbutmentsMaterials TestingGeneral DentistryEndosseous dental implantsDental ImplantsTitaniumOrthodonticsCrownsResearchConnection (principal bundle)030206 dentistry:CIENCIAS MÉDICAS [UNESCO]OtorhinolaryngologychemistryDental surgeryUNESCO::CIENCIAS MÉDICASFracture (geology)SurgeryImplants dentals intraossisImplantImplantologyImplant abutmentTitanium
researchProduct

Load-deflection characteristics of superelastic and thermal nickel-titanium wires

2011

SUMMARY The aim of this study was to investigate the mechanical properties of superelastic and thermal nickel–titanium (NiTi) archwires for correct selection of orthodontic wires. Seven different NiTi wires of two different sizes (0.014 and 0.016 inches), commonly used during the alignment phase, were tested. A three-point bending test was carried out to evaluate the load–deflection characteristics. The archwires were subjected to bending at a constant temperature of 37°C and deflections of 2 and 4 mm. Analysis of variance showed that thermal NiTi wires exerted significantly lower working forces than superelastic wires of the same size in all experimental tests (P < 0.05). Wire size had a s…

Dental Stress AnalysisTitaniumHot TemperatureMaterials scienceOrthodontic wireMetallurgyBiomechanicschemistry.chemical_elementOrthodonticsElasticityLoad deflectionchemistryNickelNickel titaniumDeflection (engineering)MartensiteThermalOrthodontic WiresComposite materialDental AlloysMechanical PhenomenaTitaniumThe European Journal of Orthodontics
researchProduct

The influence of platform switching on the biomechanical aspects of the implant-abutment system. A three dimensional finite element study

2011

Objective: To evaluate the biomechanical scenario of platform switching geometric implant-abutment configuration relative to standard configurations by means of finite element analysis.Study Design: A 3D Finite Element Analysis (FEA) was performed on 3 different implant-abutment configurations: a 3.8 mm implant with a matching diameter abutment (Standard Control Design, SCD), a 5.5 mm implant with matching diameter abutment (Wider Control Design, WCD), and a 5.5mm implant with a 3.8 mm abutment (Experimental Design, ED). All the different experimental groups were discretized to over 60000 elements and 100000 nodes, and 130N vertical (axial) and 90N horizontal loads were applied on the coron…

Dental Stress Analysisbone mechanical responseMaterials scienceimplant-abutment stresFinite Element AnalysisPlatform switchingDental Abutmentsimplant-abutment stressFinite element studyImaging Three-Dimensionalvon Mises yield criterionGeneral Dentistryplatform switchingDental Implant-Abutment Designfinite element analysis; implant-abutment stress; bone mechanical response; platform switching; implant-abutment stres:CIENCIAS MÉDICAS [UNESCO]Finite element methodBiomechanical PhenomenaStress fieldPlatform switching bone mechanical response finite element analysis implant-abutment stress.Dental Implant-Abutment DesignOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASSurgeryImplantAbutment (dentistry)Biomedical engineering
researchProduct

Measurement of gap between abutment and fixture in dental conical connection implants. A focused ion beam SEM observation

2020

Background The aim of the authors was to examine the abutment-fixture interface in Morse-type conical implants in order to verify gaps at this level using a new microscopical approach. Material and Methods In this in vitro study, 20 abutment-fixture complexes were prepared by sectioning (longitudinal and cross-sectional to the long axis) with a microtome and then with a focused ion beam (FIB). This is a micrometric machine tool that uses gallium ions to abrade circumscribed areas to dig deeper into the cuts obtained with the microtome in order to eliminate cut-induced artifacts. This is because the FIB abrasion is practically free from artifacts, which are normally generated by the action o…

Dental Stress Analysisbusiness.product_categoryMaterials scienceScanning electron microscopemicrobial leakageDental AbutmentsFixtureFocused ion beamAbrasion (geology)law.inventionSettore MED/28 - MALATTIE ODONTOSTOMATOLOGICHE03 medical and health sciences0302 clinical medicineOpticslawfocused ion beam SEMMaterials TestingMicrotomeimplant-abutment connectionGeneral DentistryDental ImplantDental Implantsbusiness.industryResearchmorse taperDental Implant-Abutment Design030206 dentistryConical surface:CIENCIAS MÉDICAS [UNESCO]Machine toolCross-Sectional StudiesOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASdental abutmentSurgerybusinessAbutment (dentistry)Implantology
researchProduct

Influence of material and diameter of pre-fabricated posts on maxillary central incisors restored with crown.

2009

Summary  Numerous research works have studied the effect of post-design parameters on the mechanical behaviour of restored teeth without reaching any clear conclusions. Previous works by the authors ascertained the effect of material and post-dimensions for non-crowned restored teeth. The aim of this work was to study the effect of post-material and diameter for crowned teeth. First, an experimental fracture strength test was performed on eighteen extracted human maxillary central incisors. Teeth were decoronated, treated endodontically and restored (nine with glass fibre posts and nine with stainless steel posts). Several post-diameters were used. The final crown restoration was carried ou…

Dental Stress Analysisinfluence of post-materialMaterials sciencemedicine.medical_treatmentGlass fiberFinite Element AnalysisDentistryCrown (dentistry)Dental Materialsstomatognathic systemFlexural strengthstress distributionMaterials TestingmedicineMaxillaHumansMaxillary central incisorDental Restoration PermanentGeneral Dentistryinfluence of post-diameterbusiness.industrybiomechanical performanceStress distributionIncisorstomatognathic diseasesDental Prosthesis DesignFracture (geology)pre-fabricated intra-radicular postsinfluence of crownFinite element techniqueGlassbusinessPost and Core TechniqueJournal of oral rehabilitation
researchProduct

Design characteristics, primary stability and risk of fracture of orthodontic mini-implants: Pilot scan electron microscope and mechanical studies

2013

Objectives: Orthodontic mini-implants (OMIs) are increasingly used in orthodontics but can fail for various reasons. This study investigates the effects of OMI design characteristics on the mechanical properties in artificial bone. Material and Methods: Twelve self-drilling OMIs (2 small, 6 medium, 4 large) from 8 manufacturers were tested for their primary stability in simulated medium-high cancellous bone and the risk to fracture in high-density methacrylate blocks. For the assessments of the maximum insertion torque (IT) and torsional fracture (TF) 5 of each OMI were used and for the pull-out strength (POS) 10. The OMIs were inserted with a torque screwdriver (12 sec/360°) until the bott…

Insertion torqueDental Stress Analysisprimary stabilityArtificial boneMaterials scienceorthodontic mini-implantsTorsion MechanicalOdontologíatorsional fractureProsthesis Designpullout strengthDesign characteristicslaw.inventionMecànica de fracturalawRisk FactorsMaterials TestingBiomaterials and Bioengineering in DentistrymedicineOrthodontic Anchorage ProceduresFracture mechanicsGeneral Dentistry:Enginyeria dels materials::Desgast de materials [Àrees temàtiques de la UPC]Implants artificialsTorsion (mechanics)Implants ArtificialPullout strength:CIENCIAS MÉDICAS [UNESCO]Ciencias de la saludProsthesis Failuremedicine.anatomical_structureOtorhinolaryngologyMini implantsUNESCO::CIENCIAS MÉDICASMicroscopy Electron ScanningSurgeryResearch-ArticleElectron microscopeCancellous boneinsertion torqueBiomedical engineering
researchProduct

Primary Stability of a Hybrid Self-Tapping Implant Compared to a Cylindrical Non-Self-Tapping Implant with Respect to Drilling Protocols in an Ex Viv…

2011

Background: Modifications of implant design have been intending to improve primary stability. However, little is known about investigation of a hybrid self-tapping implant on primary stability. Purposes: The aims of this study were to evaluate the primary stability of two hybrid self-tapping implants compared to one cylindrical non-self-tapping implant, and to elucidate the relevance of drilling protocols on primary stability in an ex vivo model. Materials and Methods: Two types of hybrid self-tapping implants (Straumann® Bone Level implant [BL], Straumann® Tapered Effect implant [TE]) and one type of cylindrical non-self-tapping implant (Straumann® Standard Plus implant [SP]) were investig…

Insertion torqueMaterials sciencebusiness.industrymedicine.medical_treatmentImplant designDentistryResonance frequency analysisDental Stress AnalysismedicineImplantOral SurgeryBone levelDental implantbusinessGeneral DentistryEx vivoClinical Implant Dentistry and Related Research
researchProduct

Molar distalization with pendulum appliances in the mixed dentition: effects on the position of unerupted canines and premolars.

2004

Introduction: The pendulum appliance allows for rapid molar distalization without the need for patient compliance. Its efficiency has been confirmed in a number of clinical studies. However, the potential interactions and positional changes between the deciduous molars used for dental anchorage and the erupted and unerupted permanent teeth have yet to be clarified when this appliance is used for molar distalization in the mixed dentition. Methods: Twenty-nine patients in the mixed dentition each received a modified pendulum appliance with a distal screw and a preactivated pendulum spring for bilateral distalization of the maxillary molars. The patients were divided into 4 groups based on de…

MolarDental Stress AnalysisMaleCuspidDentition MixedTooth Movement TechniquesCephalometryTooth eruptionDentistryOrthodonticsTooth Eruptionstomatognathic systemOrthodontic AppliancesPremolarMaxillaOrthodontic Anchorage ProceduresMedicineHumansBicuspidTooth UneruptedChildPermanent teethOrthodonticsAnalysis of VarianceDentitionbusiness.industryContraindicationsPendulumCraniometryMolarDentition Permanentmedicine.anatomical_structureMaxillaFemalebusinessMalocclusionAmerican journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics
researchProduct