Search results for "Dental prosthesis design"
showing 10 items of 62 documents
Descriptive retrospective study analyzing relevant factors related to dental implant failure
2019
Background The objective of this retrospective descriptive study was to analyze the characteristics of incident reports provided by dentists while using a specific brand of dental implants. Material and Methods The study was carried out in collaboration with Oxtein Iberia S.L.®, with the company providing access to the incident database in order to evaluate the characteristics of incidents from January 2014 to December 2017 (a total of 917 over four years). The data sheet recorded different variables during each of the stages of implant treatment, from initial implant placement to subsequent prosthetic rehabilitation. These variables included age, sex, systemic pathologies, smoking habits, …
Implant treatment in atrophic posterior mandibles: Vertical regeneration with block bone grafts versus implants with 5.5-mm intrabony length
2014
Purpose: To retrospectively compare the outcomes of implants placed in posterior mandibles vertically regenerated with onlay autogenous block bone grafts and short dental implants. Materials and Methods: Consecutive patients with vertical bone atrophy in edentulous mandibular posterior regions (7 to 8 mm of bone above the inferior alveolar nerve) were treated with either implants placed in regenerated bone using autologous block bone grafts (group 1) or short implants (with 5.5-mm intrabony length) in native bone (group 2) between 2005 and 2010 and followed for 12 months after loading. The procedure used was the established treatment protocol for this type of patient at the Oral Surgery Uni…
Survival and tissue maintenance of an implant with a sloped configurated shoulder in the posterior mandible-a prospective multicenter study.
2016
Aim Clinical studies evaluating the influence of the implant design on the preservation of peri-implant keratinized mucosa are rare. The aim of this prospective multicenter study was to investigate the survival, and soft and hard tissue maintenance of an implant with a sloped shoulder configuration, when placed in the posterior mandible. Material and Methods In this study, 24 centers participated and 184 patients receiving 238 implants (OsseoSpeed™ Profile TX implants) were included. Clinical assessments of soft tissue parameters were performed before implant placement, immediately after implant placement, at prosthetic delivery and at 6, 12 and 24 months after implant placement and margina…
Influence of plasma cleaning procedure on the interaction between soft tissue and abutments: a randomized controlled histologic study
2016
Introduction Plasma application can lead to an improved adhesion between soft tissue and abutments and promotes cell spreading. Objective A triple-blinded randomized controlled clinical trial was performed to in vivo test the effect of cleaning abutment titanium surfaces with plasma of argon on cell adhesion and collagen fiber orientation at an early healing time. Material and methods Thirty healthy patients with 30 submerged implants, at the second surgery, randomly received either a specially designed abutment with no additional treatment (as they come from industry; control group, G1) or cleaned by plasma of argon (test group, G2). Two weeks thereafter, a small biopsy including abutment …
Survival of immediately versus delayed loaded short implants: a prospective case series study
2015
Background: To assess and compare survival rates of immediately and delayed loaded short implants (7 mm) in free ends of a partially edentulous jaw with moderate-severe alveolar bone resorption. Material and Methods: 24 patients with atrophic edentulous free-ends were included in this prospective study. Four study groups were monitored monthly and their behavior was evaluated: bridges supported only by short implants and mixed short and long implant bridge groups, both with immediate and delayed loading. Failures, bone loss, probing depth and bleeding on probing were evaluated. Results: 54 Mk III Shorty TiU and 15 Brånemark System®MK III TiU implants with a length longer than 7mm were inclu…
Soft and hard tissue alterations around implants placed in an alveolar ridge with a sloped configuration.
2012
Aim: The aim of this study was to evaluate soft and hard tissue alterations around implants placed in healed, sloped ridge sites. Materials and methods: In this prospective multi-center study, 65 patients between 20 and 74 years of age and with a need for a single tooth replacement were included. All patients presented with a recipient implant site demonstrating a lingual‐buccal bone height discrepancy of 2.0‐5.0 mm and with a neighboring tooth on its mesial aspect. Implant placement (OsseoSpeed Profile implants; Astra Tech AB, M! olndal, Sweden) was performed using a non-submerged installation procedure. The implants were placed in such a way that the sloped part of the device was located …
Does Apico-Coronal Implant Position Influence Peri-Implant Marginal Bone Loss? A 36-Month Follow-Up Randomized Clinical Trial
2019
Purpose Preserving peri-implant bone and reducing exposure of the rough implant surface might influence long-term outcomes of implant therapy. The aim of this study was to compare peri-implant clinical and radiologic parameters after crestal and subcrestal dental implant placement at 36 months' follow-up. Materials and Methods We carried out a randomized clinical trial involving partially edentulous patients in need of an implant-supported, partial fixed dental prosthesis or a single crown. Patients were randomized according to the implant insertion depth: implants placed approximately 2 mm below the bone crest (test group) or implants placed at bone crest level (control group). They were e…
Clinical and radiographic performance of self‐locking conical connection implants in the posterior mandible: Five‐year results of a two‐centre prospe…
2021
Abstract Objective This prospective study aims to assess the 5‐year clinical performance of implants with internal conical connection and platform‐switched abutments in the posterior mandible. Material and Methods Healthy adults missing at least two teeth in the posterior mandible and with a natural tooth mesial to the implant site received two or three adjacent implants. After a transmucosal healing period single crown restorations were cemented on platform‐switched abutments. Changes in marginal bone levels were investigated in standardized periapical radiographs from surgery and loading (baseline) to 60‐months post‐loading. Results Twenty‐four patients received 52 implants. Bone remodell…
Oval fiber posts do not improve adaptation to oval-shaped canal walls.
2011
Abstract Introduction Oval fiber posts attempt to provide better adaptation to root canals. The hypothesis of this study was that there are no differences in adaptation of oval and circular fiber posts to canal walls. Methods Posts were inserted in 20 canals; 10 were oval, and 10 were circular. The posts were cemented with composite cement. Coronal, middle, and apical sections were observed through a microscope. The space occupied by the post and the maximum distance between it and the canal wall were calculated. The 2 groups were compared with analysis of variance. In all the analyses the level of significance was set at P Results The proportion of space occupied by the post showed no sign…
A biphasic calcium phosphate coating for potential drug delivery affects early osseointegration of titanium implants.
2016
Background Calcium phosphate (CaP) surface coatings may accelerate osseointegration and serve as a drug delivery system for mineral-binding biomolecules. In a pilot study, the impact of a commercially available, thin CaP coating on early osseous bone remodeling was compared with a modern, subtractive-treated rough surface (SLA-like) in an animal trial. Methods In 16 rabbits, 32 endosseous implants (CaP; n = 16, SLA-like; n = 16) were bilaterally inserted in the proximal tibia after randomization. After 2 and 4 weeks, bone-implant contact (BIC;%) in the cortical (cBIC) and the trabecular bone (sBIC) as well as volume of bone within the screw thread with the highest amount of new-formed bone …