Search results for "Dental prosthesis design"
showing 10 items of 62 documents
Influence of prefabricated post dimensions on restored maxillary central incisors
2007
summary The aim of this study was to test the following hypothesis: biomechanical performance (fracture strength and stress distribution) of restored teeth is less sensitive to post diameter and post length when using glass fibre posts than when using stainless steel posts. First, an experimental fracture strength test was performed on 80 extracted human maxillary central incisors. Teeth were decoronated, treated endodontically and restored (40 with glass fibre posts and 40 with stainless steel posts), and the length and diameter of the posts varied uniformly. Failure loads were recorded and results were compared using an ancova analysis. Secondly, the finite element technique was used to …
Premolars restored with posts of different materials: fatigue analysis
2011
Previous works studied the effect of the material and the dimensions of the post on the biomechanical performance (fracture strength and stress distribution) of restored teeth, under static loads. The aim of this work was to study the effect of the post material (glass fibre and stainless steel) on restored teeth, which have the final crown, under dynamic conditions. The use of a biomechanical model, including a fatigue analysis from FEA, is presented as a powerful method to study the effect of the material of the intraradicular post. The inclusion of the fatigue analysis allows for a more realistic study that takes into account the dynamic nature of masticatory forces. At the same time, th…
Influence of material and diameter of pre-fabricated posts on maxillary central incisors restored with crown.
2009
Summary Numerous research works have studied the effect of post-design parameters on the mechanical behaviour of restored teeth without reaching any clear conclusions. Previous works by the authors ascertained the effect of material and post-dimensions for non-crowned restored teeth. The aim of this work was to study the effect of post-material and diameter for crowned teeth. First, an experimental fracture strength test was performed on eighteen extracted human maxillary central incisors. Teeth were decoronated, treated endodontically and restored (nine with glass fibre posts and nine with stainless steel posts). Several post-diameters were used. The final crown restoration was carried ou…
A facially driven complete-mouth rehabilitation with ultrathin CAD-CAM composite resin veneers for a patient with severe tooth wear: A minimally inva…
2020
Abstract The development of technologies that include face scanning and dental software has improved workflows in dentistry. Digital files make it possible to create a 3-dimensional virtual image of the patient that helps the clinician plan treatment and make decisions, reducing uncertainty and improving communication. This report describes the complete-mouth rehabilitation of a patient with severe tooth wear. The treatment adopted a minimal intervention approach, applying adhesive veneers in areas where the tooth structure was affected and used a computer-aided design and computer-aided manufacturing (CAD-CAM) workflow to prepare nanoceramic composite resin materials with a high filler loa…
Zirconia implant abutments: A review
2009
Objectives: An increasing aesthetic demand within developed populations conducted to the fabrication of metalfree restorations and to a wide use of ceramic materials, due to its excellent characteristics of biocompatibility and aesthetics. With the incessant increase of commercial labels involved in this technological advance, a review is imposed on ceramic abutments, specifically on zirconia. We made a search of articles of peer-reviewed Journals in PubMed/ Medline, crossing the terms ?Dental Abutments?, ?Dental Porcelain? and ?Zirconia?. The review was divided by subtopics: zirconia physical and mechanical properties, precision fit in the implant-abutment interface, zirconia abutments str…
Rehabilitation of the atrophic posterior maxilla with pterygoid implants: a review.
2012
The purpose of this article is to review the literature published and to assess the success of treatment of patients with atrophic posterior maxilla with pterygoid implants. Studies from 1992 to 2009 on patients with atrophic posterior maxilla rehabilitated with pterygoid implants were reviewed. Those reporting clinical series of at least 5 patients with atrophic posterior maxilla (Class IV and V of Cawood and Howell), rehabilitated with pterygoid implants and fixed prosthesis, and with 12 months minimum follow-up were included. In each study the following were assessed: number of patients, number of implants, surgical technique, prosthetic rehabilitation, success rate, bone loss, complica…
Vertical preparation for fixed prosthesis rehabilitation in the anterior sector
2015
This clinical report describes a biologically oriented preparation technique (BOPT) for teeth and an implant for the esthetic rehabilitation of the maxillary anterior sector. The technique was designed to create an anatomic crown with a prosthetic emergence profile that simulated the shape of the natural tooth.
Immediate and flapless implant insertion and provisionalization using autogenous bone grafts in the esthetic zone: 5-year results.
2017
Objectives As the 2-year results for immediately inserted and provisionalized implants have been reported, it remained an open issue, whether the initially high success rates and the esthetic outcome remain stable for longer observation periods. Therefore, this prospective study examines the 5-year hard and soft tissue changes at implants placed in the anterior maxilla. Material and methods Meanwhile, 37 microthreaded implants were placed in 21 patients into extraction sockets with and without facial bone deficiencies by a flapless approach. Facial gaps and bony defects were grafted with autogenous bone chips. The implants were immediately provisionalized. The primary outcome parameters wer…
Effect of platform switching on crestal bone levels around implants in the posterior mandible: 3 years results from a multicentre randomized clinical…
2016
Objective Evaluation of differences in the clinical performance and crestal bone levels between implants restored with single crowns with platform-matched or platform-switched abutments after 3 years. Material and Methods The study enrolled adult patients missing two or more adjacent teeth in the posterior mandible with natural teeth mesial to the implant site. Randomization followed open-flap implant insertion and the corresponding matching or switching healing abutments placed at surgery. Conventional loading was made with cemented crowns. Clinical follow-up took place annually after loading up to 3 years. Bone level changes were measured in standardized radiographs as the variation in cr…
Straight and tilted implants for supporting screw-retained full-arch dental prostheses in atrophic maxillae : a 2-year prospective study
2018
Background To evaluate, over a 2-year period, the treatment outcomes for maxillary full-arch fixed dental prostheses (FDPs) supported by a combination of both tilted and axially-placed implants and to compare the marginal bone loss (MBL) and implant survival rates (SR) between tilted and axial implants. Material and Methods A retrospective study has been carried out. Thirty-two patients (16 males and 16 females) treated with maxillary full-arch FDPs were included in this retrospective study. A total of 187 implants were inserted to rehabilitate the fully edentulous maxillary arches: 36% of them were tilted (T group, n = 68) and the remaining 64% were axially placed (A group, n = 119). From …