Tilted implants for the restoration of posterior mandibles with horizontal atrophy: An alternative treatment

2013

Purpose Horizontal atrophy in the posterior mandible presents serious limitations on conventional implant placement. The purpose of this study was to evaluate the use of tilted implants angled in a buccolingual direction for restoring atrophic posterior mandibular sectors. Materials and Methods A cohort study was performed of 25 patients who had partial prostheses supported by more than 1 implant (≥1 tilted and 1 axial implant) to restore molar areas in the mandible. When the bone thickness was at least 5 mm, axial implants were placed; when the alveolar ridge was narrower, the implant was placed with tilted angulation. The beds for these tilted implants were prepared using a lingual approa…

MolarAdultMaleBone thicknessAlveolar Bone LossDentistryMandibleCohort StudiesAtrophyDental ArchAlveolar ridgemedicineHumansAgedDental ImplantsBone TransplantationCrownsbusiness.industryDental prosthesisDental Implantation EndosseousMandibleDental Implant-Abutment DesignMiddle Agedmedicine.diseaseAlternative treatmentTreatment OutcomeOtorhinolaryngologyDental Prosthesis DesignBone SubstitutesDenture Partial FixedSurgeryFemaleImplantDental Prosthesis Implant-SupportedOral SurgeryAtrophybusinessFollow-Up Studies
researchProduct

Digital protocol for creating a virtual gingiva adjacent to teeth with subgingival dental preparations.

2019

Abstract Purpose This article describes a digital technique used to record gingival emergence profiles modeled for the prosthetic restoration of teeth prepared using biologically oriented preparation technique (BOPT). Materials and methods The description of the technique of intraoral recording, manipulation of digital files, and chairside protocol of prosthetic restorations is developed in the present manuscript on two anterior teeth treated with vertical and subgingival dental preparations for restoration with ceramic crowns. The manipulation of the digital files registered with an intraoral scanner with software that allows its alignment (best-fit) and the performance boolean of operatio…

OrthodonticsIntraoral scannerPeriodontal tissueCrownsComputer sciencemedicine.medical_treatment0206 medical engineeringGingiva030206 dentistry02 engineering and technology020601 biomedical engineeringProsthesis03 medical and health sciences0302 clinical medicineDental Prosthesis DesignDental Prosthesis DesignmedicineDentistry (miscellaneous)Gingival sulcusOral SurgeryToothAnterior teethJournal of prosthodontic research
researchProduct

Implant-supported overdenture manufactured using CAD/CAM techniques to achieve horizontal path insertion between the primary and secondary structure:…

2015

This report describes the case of an edentulous patient with an atrophic maxilla and severe class III malocclusion. Prosthetic rehabilitation was performed using CAD/CAM techniques for manufacturing an implant-supported overdenture with horizontal insertion. A vestibulo-lingual insertion overdenture is a precision prosthesis with a fixation system affording a good fit between the primary and secondary structure. Both structures exhibit passive horizontal adjustment. This treatment option requires the same number of implants as implant-supported fixed dentures. The horizontal assembly system prevents the prosthesis from loosening or moving in response to axial and non-axial forces. The techn…

Orthodonticsbusiness.industrymedicine.medical_treatmentDental prosthesisDental implantsDentistryCADCase ReportHorizontal insertion prosthesisDental prosthesis designProsthesisFixation (surgical)Horizontal Denture®MaxillamedicineDental Prosthesis DesignDentistry (miscellaneous)Clinical caseOral SurgeryDenturesbusinessEdentulous jawAlveolar bone atrophyThe Journal of Advanced Prosthodontics
researchProduct

Multiple teeth replacement with endosseous one-piece yttrium-stabilized zirconia dental implants

2012

Objectives: The purpose of this study is to clinically and radiographically evaluate survival and success rate of multiple zirconia dental implants positioned in each patient during a follow-up period of at least 12 months up to 48 months. Study Design: Eight patients were treated for multiple edentulism with 29 zirconia dental implants. All implants received immediate temporary restorations and 6 months after surgery were definitively restored. 6 months to 4 years after implant insertion, a clinical-radiographic evaluation was performed in order to estimate peri-implant tissues health and peri-implant marginal bone loss. Results: Survival rate within follow-up period was therefore 100%. Th…

RadiographyDentistryOdontologíamedicineDental Prosthesis DesignHumansYttriumGeneral DentistrySurvival rateAgedDental ImplantsEdentulismBone preservationbusiness.industryDental Implantation EndosseousMiddle Agedmedicine.disease:CIENCIAS MÉDICAS [UNESCO]Ciencias de la saludProsthesis FailureDental Prosthesis DesignOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASResearch-ArticleSurgeryZirconiumImplantOral SurgerybusinessAbutment (dentistry)
researchProduct

Small-diameter titanium Grade IV and titanium-zirconium implants in edentulous mandibles: three-year results from a double-blind, randomized controll…

2015

OBJECTIVE: The aim of this study was to compare crestal bone-level changes, soft tissue parameters and implant success and survival between small-diameter implants made of titanium/zirconium (TiZr) alloy or of Grade IV titanium (Ti) in edentulous mandibles restored with removable overdentures. MATERIALS AND METHODS: This was a randomized, controlled, double-blind, split-mouth multicenter clinical trial. Patients with edentulous mandibles received two Straumann bone-level implants (diameter 3.3 mm), one of Ti Grade IV (control) and one of TiZr (test), in the interforaminal region. Implants were loaded after 6-8 weeks and removable Locator-retained overdentures were placed within 2 weeks of l…

RoxolidMaleSmall diameterSLActive surfaceDentistrychemistry.chemical_elementMandibleCONVENTIONAL COMPLETE DENTURESlaw.inventionDouble blindRETROSPECTIVE EVALUATION IMPLANTDouble-Blind MethodRandomized controlled triallawMARGINAL BONE LOSSHumansJaw EdentulousMedicineMANDIBULAR 2-IMPLANT OVERDENTURES610 Medicine & healthAgedDental ImplantsTitaniumPATIENT SATISFACTIONTitanium/zirconiumSTRESS-DISTRIBUTIONbusiness.industryDental Implantation Endosseoustechnology industry and agricultureWITHIN-SUBJECT COMPARISONSSoft tissueDIFFERENT LOADING PROTOCOLSDenture Overlayequipment and suppliesTitanium zirconiumddc:617.6Treatment OutcomeDental Prosthesis DesignchemistryImplant typesedentulousFemaleZirconiumImplantFINITE-ELEMENT-ANALYSISOral SurgerybusinessDental AlloysTitaniumClinical Oral Implants Research
researchProduct

Small-diameter titanium grade IV and titanium-zirconium implants in edentulous mandibles: five-year results from a double-blind, randomized controlle…

2015

BACKGROUND The aim of this study was to compare the 5-year survival and success rates of 3.3 mm dental implants either made from titanium-zirconium (TiZr) alloy or from Grade IV titanium (Ti Grade IV) in mandibular implant-based removable overdentures. METHODS The core study had a follow-up period of 36 months and was designed as a randomized, controlled, double-blind, split-mouth multicenter clinical trial. Patients with edentulous mandibles received two Straumann Bone Level implants (diameter 3.3 mm, SLActive®), one of TiZr (test) and one of Ti Grade IV (control), in the interforaminal region. This follow-up study recruited patients from the core study and evaluated the plaque and sulcus …

RoxolidSmall diameterSplit-mouthDentistrychemistry.chemical_element610 Medicine & healthMandiblelaw.inventionTiZrDouble blindstomatognathic systemRandomized controlled trialDouble-Blind MethodlawOverdenturesAlloysMedicineHumansJaw Edentulous610 Medicine & healthGeneral DentistrySurvival rateOrthodonticsDental ImplantsTitaniumbusiness.industryDentistry(all)Ti Grade IVDental Implantation Endosseoustechnology industry and agricultureSLActiveequipment and suppliesDenture OverlayTitanium zirconiumddc:617.6stomatognathic diseaseschemistryDental Prosthesis DesignOral and maxillofacial surgeryImplantZirconiumbusinessTitaniumFollow-Up StudiesResearch Article
researchProduct

Short implants (8mm) versus longer implants (≥8mm) with lateral sinus floor augmentation in posterior atrophic maxilla: A meta-analysis of RCT`s in h…

2019

Background One of the greatest challenges that dentists face today is to rehabilitate severe atrophied alveolar ridges in partially and completely edentulous patients with implants. Despite the high survival rate of implants placed next to sinus elevation, this technique presents complications that can be avoided by placing short implants, an option that also presents high survival rates. For this reason, the aim of this study is to compare the survival rate, marginal bone loss and complications associated with short implants (<8 mm) versus longer implants (≥8mm) placed with lateral sinus floor elevation in posterior atrophic maxillae. Material and Methods A literature search was conducted …

Survival rateComplicationsAugment del sòl sinusal lateralDentistryReviewlaw.invention0302 clinical medicineRandomized controlled triallawMaxillaMedicineDental Restoration FailurePèrdua òssia marginalImplante cortoImplantes dentalesDental Implantation Endosseous:CIENCIAS MÉDICAS [UNESCO]Lateral sinusShort implantsTreatment OutcomeRandomized controlled trialMeta-analysisUNESCO::CIENCIAS MÉDICASLateral sinus floor augmentationOdontologyImplantologySinus Floor AugmentationPérdida ósea marginalEnsayo controlado aleatorizadoSinus Floor AugmentationOdontología616.3Odontologia03 medical and health sciencesAumento del suelo del seno lateralStatistical significanceTasa de supervivenciaHumansAssaig controlat aleatoriGeneral DentistrySurvival rateDental ImplantsImplants dentalsComplicacionsbusiness.industryMarginal bone lossTaxa de supervivènciaImplant curt030206 dentistryComplicacionesShort implantOtorhinolaryngologyDental Prosthesis DesignMaxillaSurgerybusinessMedicina oral, patologia oral y cirugia bucal
researchProduct

Is clinical experience important for obtaining the primary stability of dental implants with aggressive threads? An ex vivo study

2018

GECKILI, ONUR/0000-0002-7852-3915; dayan, suleyman cagatay/0000-0003-3081-9618; Bilhan, Hakan/0000-0003-1787-3003 WOS:000460131200015 PubMed ID: 30818319 Background: The aim of this study was to investigate the clinicians' experience on maintaining the primary stability of implants with aggressive threads belonging to a novel dental implant system. Material and Methods: Three hundred implants with aggressive threads were inserted in fresh bovine ribs mimicking Type IV bone by five clinicians which were classified according to their previous experience of total number of implant insertion. An independent examiner measured the primary stability of all implants after insertion by using resonan…

experimental designmedicine.medical_treatmentDentistryIn Vitro TechniquesOsseointegration03 medical and health sciences0302 clinical medicineOsseointegrationmedicineDental Prosthesis DesignAnimalsDental implantGeneral DentistryDental Implantsbusiness.industryResearchDental Implantation EndosseousDental Modelsosseointegration030206 dentistry:CIENCIAS MÉDICAS [UNESCO]Models DentalBiomechanical PhenomenaResonance frequency analysisDental Implant-Abutment DesignOtorhinolaryngologyDental Prosthesis DesignTorqueResearch DesignUNESCO::CIENCIAS MÉDICASSurgeryCattleImplantOral SurgerybusinessImplantologyEx vivo
researchProduct

Assessing osseointegration of metallic implants with boronized surface treatment

2020

Background Modification of endosteal implants through surface treatments have been investigated to improve osseointegration. Boronization has demonstrated favorable mechanical properties, but limited studies have assessed translational, in vivo outcomes. This study investigated the effect of implant surface boronization on bone healing. Material and Methods Two implant surface roughness profiles (acid etched, machined) in CP titanium (type II) alloy implants were boronized by solid-state diffusion until 10-15µm boron coating was achieved. The surface-treated implants were placed bilaterally into 5 adult sheep ilia for three and six weeks. Four implant groups were tested: boronized machined …

inorganic chemicalsBone RegenerationMaterials scienceSurface Propertieschemistry.chemical_elementBone healingOsseointegration03 medical and health sciences0302 clinical medicineOsseointegrationAnimalsBone regenerationGeneral DentistryDental ImplantsTitaniumSheepResearchDental Implantation Endosseous030206 dentistry:CIENCIAS MÉDICAS [UNESCO]Bone to implant contactDental Prosthesis DesignOtorhinolaryngologychemistryUNESCO::CIENCIAS MÉDICASImplant typesSurgeryImplantAdult sheepImplantologyBiomedical engineeringTitaniumMedicina Oral Patología Oral y Cirugia Bucal
researchProduct

Four color-measuring devices compared with a spectrophotometric reference system

2009

Abstract Objectives The objective of this study was to compare the L*C*h° color coordinates of dental color-measuring devices with those of a spectrophotometric reference system. Methods The International Commission on Illumination (CIE) L*C*h° color coordinates of ceramic samples, matching the colors of the VITA Linearguide, were recorded using four color-measuring devices (VITA Easyshade (A), VITA Easyshade compact (B), Degudent Shadepilot (C), X-Rite Shadevision (D)) and a spectrophotometric reference system under standardized test conditions. The intraclass correlation coefficients, regression lines with coefficients of determination, and mean deviations of the dental color-measuring de…

medicine.diagnostic_testProsthesis ColoringIntraclass correlationAnalytical chemistryColorReproducibility of ResultsRepeatabilityDental Prosthesis DesignSpectrophotometrySpectrophotometryLinear regressionLinear ModelsmedicineMeasuring instrumentHumansTooth DiscolorationColorimetryColorimetryGeneral DentistryColor coordinatesHueMathematicsJournal of Dentistry