Search results for "Dental prosthesis design"
showing 10 items of 62 documents
Tilted implants for the restoration of posterior mandibles with horizontal atrophy: An alternative treatment
2013
Purpose Horizontal atrophy in the posterior mandible presents serious limitations on conventional implant placement. The purpose of this study was to evaluate the use of tilted implants angled in a buccolingual direction for restoring atrophic posterior mandibular sectors. Materials and Methods A cohort study was performed of 25 patients who had partial prostheses supported by more than 1 implant (≥1 tilted and 1 axial implant) to restore molar areas in the mandible. When the bone thickness was at least 5 mm, axial implants were placed; when the alveolar ridge was narrower, the implant was placed with tilted angulation. The beds for these tilted implants were prepared using a lingual approa…
Digital protocol for creating a virtual gingiva adjacent to teeth with subgingival dental preparations.
2019
Abstract Purpose This article describes a digital technique used to record gingival emergence profiles modeled for the prosthetic restoration of teeth prepared using biologically oriented preparation technique (BOPT). Materials and methods The description of the technique of intraoral recording, manipulation of digital files, and chairside protocol of prosthetic restorations is developed in the present manuscript on two anterior teeth treated with vertical and subgingival dental preparations for restoration with ceramic crowns. The manipulation of the digital files registered with an intraoral scanner with software that allows its alignment (best-fit) and the performance boolean of operatio…
Implant-supported overdenture manufactured using CAD/CAM techniques to achieve horizontal path insertion between the primary and secondary structure:…
2015
This report describes the case of an edentulous patient with an atrophic maxilla and severe class III malocclusion. Prosthetic rehabilitation was performed using CAD/CAM techniques for manufacturing an implant-supported overdenture with horizontal insertion. A vestibulo-lingual insertion overdenture is a precision prosthesis with a fixation system affording a good fit between the primary and secondary structure. Both structures exhibit passive horizontal adjustment. This treatment option requires the same number of implants as implant-supported fixed dentures. The horizontal assembly system prevents the prosthesis from loosening or moving in response to axial and non-axial forces. The techn…
Multiple teeth replacement with endosseous one-piece yttrium-stabilized zirconia dental implants
2012
Objectives: The purpose of this study is to clinically and radiographically evaluate survival and success rate of multiple zirconia dental implants positioned in each patient during a follow-up period of at least 12 months up to 48 months. Study Design: Eight patients were treated for multiple edentulism with 29 zirconia dental implants. All implants received immediate temporary restorations and 6 months after surgery were definitively restored. 6 months to 4 years after implant insertion, a clinical-radiographic evaluation was performed in order to estimate peri-implant tissues health and peri-implant marginal bone loss. Results: Survival rate within follow-up period was therefore 100%. Th…
Small-diameter titanium Grade IV and titanium-zirconium implants in edentulous mandibles: three-year results from a double-blind, randomized controll…
2015
OBJECTIVE: The aim of this study was to compare crestal bone-level changes, soft tissue parameters and implant success and survival between small-diameter implants made of titanium/zirconium (TiZr) alloy or of Grade IV titanium (Ti) in edentulous mandibles restored with removable overdentures. MATERIALS AND METHODS: This was a randomized, controlled, double-blind, split-mouth multicenter clinical trial. Patients with edentulous mandibles received two Straumann bone-level implants (diameter 3.3 mm), one of Ti Grade IV (control) and one of TiZr (test), in the interforaminal region. Implants were loaded after 6-8 weeks and removable Locator-retained overdentures were placed within 2 weeks of l…
Small-diameter titanium grade IV and titanium-zirconium implants in edentulous mandibles: five-year results from a double-blind, randomized controlle…
2015
BACKGROUND The aim of this study was to compare the 5-year survival and success rates of 3.3 mm dental implants either made from titanium-zirconium (TiZr) alloy or from Grade IV titanium (Ti Grade IV) in mandibular implant-based removable overdentures. METHODS The core study had a follow-up period of 36 months and was designed as a randomized, controlled, double-blind, split-mouth multicenter clinical trial. Patients with edentulous mandibles received two Straumann Bone Level implants (diameter 3.3 mm, SLActive®), one of TiZr (test) and one of Ti Grade IV (control), in the interforaminal region. This follow-up study recruited patients from the core study and evaluated the plaque and sulcus …
Short implants (8mm) versus longer implants (≥8mm) with lateral sinus floor augmentation in posterior atrophic maxilla: A meta-analysis of RCT`s in h…
2019
Background One of the greatest challenges that dentists face today is to rehabilitate severe atrophied alveolar ridges in partially and completely edentulous patients with implants. Despite the high survival rate of implants placed next to sinus elevation, this technique presents complications that can be avoided by placing short implants, an option that also presents high survival rates. For this reason, the aim of this study is to compare the survival rate, marginal bone loss and complications associated with short implants (<8 mm) versus longer implants (≥8mm) placed with lateral sinus floor elevation in posterior atrophic maxillae. Material and Methods A literature search was conducted …
Is clinical experience important for obtaining the primary stability of dental implants with aggressive threads? An ex vivo study
2018
GECKILI, ONUR/0000-0002-7852-3915; dayan, suleyman cagatay/0000-0003-3081-9618; Bilhan, Hakan/0000-0003-1787-3003 WOS:000460131200015 PubMed ID: 30818319 Background: The aim of this study was to investigate the clinicians' experience on maintaining the primary stability of implants with aggressive threads belonging to a novel dental implant system. Material and Methods: Three hundred implants with aggressive threads were inserted in fresh bovine ribs mimicking Type IV bone by five clinicians which were classified according to their previous experience of total number of implant insertion. An independent examiner measured the primary stability of all implants after insertion by using resonan…
Assessing osseointegration of metallic implants with boronized surface treatment
2020
Background Modification of endosteal implants through surface treatments have been investigated to improve osseointegration. Boronization has demonstrated favorable mechanical properties, but limited studies have assessed translational, in vivo outcomes. This study investigated the effect of implant surface boronization on bone healing. Material and Methods Two implant surface roughness profiles (acid etched, machined) in CP titanium (type II) alloy implants were boronized by solid-state diffusion until 10-15µm boron coating was achieved. The surface-treated implants were placed bilaterally into 5 adult sheep ilia for three and six weeks. Four implant groups were tested: boronized machined …
Four color-measuring devices compared with a spectrophotometric reference system
2009
Abstract Objectives The objective of this study was to compare the L*C*h° color coordinates of dental color-measuring devices with those of a spectrophotometric reference system. Methods The International Commission on Illumination (CIE) L*C*h° color coordinates of ceramic samples, matching the colors of the VITA Linearguide, were recorded using four color-measuring devices (VITA Easyshade (A), VITA Easyshade compact (B), Degudent Shadepilot (C), X-Rite Shadevision (D)) and a spectrophotometric reference system under standardized test conditions. The intraclass correlation coefficients, regression lines with coefficients of determination, and mean deviations of the dental color-measuring de…