Search results for "Design"

showing 10 items of 5885 documents

Comparative analysis of numerical and experimental data of orthodontic mini-implants

2011

The purpose of this study was to compare numerical simulation data derived from finite element analysis (FEA) to experimental data on mini-implant loading. Nine finite element (FE) models of mini-implants and surrounding bone were derived from corresponding experimental specimens. The animal bone in the experiment consisted of bovine rib. The experimental groups were based on implant type, length, diameter, and angle of insertion. One experimental specimen was randomly selected from each group and was digitized in a microCT scanner. The FE models consisted of bone pieces containing Aarhus mini-implants with dimensions 1.5 × 7 mm and 1.5 × 9 mm or LOMAS mini-implants (dimensions 1.5 × 7 mm, …

Dental Stress AnalysisMaterials science9 mm caliberFinite Element AnalysisOrthodontics610 Medicine & health10067 Clinic for Orthodontics and Pediatric DentistryDisplacement (vector)Stress (mechanics)Imaging Three-DimensionalOrthodontic Anchorage ProceduresPerpendicularAnimalsOrthodontic Appliance DesignDental ImplantsModels Statisticalbusiness.industry3505 OrthodonticsBiomechanicsExperimental dataX-Ray MicrotomographyStructural engineeringFinite element methodBiomechanical PhenomenaCattleStress MechanicalbusinessRotation (mathematics)
researchProduct

Influence of prefabricated post material on restored teeth: fracture strength and stress distribution.

2006

This work studied how prefabricated intraradicular post material affects the mechanical performance of restored teeth. The effect of using two different materials (glass fiber and stainless steel) with significantly different elastic moduli was studied.A combined theoretical and experimental method was used: first, an experimental fracture strength test was performed on 60 extracted human maxillary central incisors. The teeth were decoronated, treated endodontically and restored, 30 with glass fiber posts and 30 with stainless steel posts. The data were recorded and the results compared using an ANOVA test. Then, the finite element technique was used to develop a model of the restored tooth…

Dental Stress AnalysisMaterials scienceFinite Element AnalysisDentistryMaterials testingModels BiologicalStress (mechanics)Dental MaterialsTooth Fracturesstomatognathic systemFlexural strengthMaterials TestingDentinmedicineHumansComputer SimulationGeneral DentistryElastic modulusTooth Nonvitalbusiness.industryStress distributionElasticity (physics)Stainless SteelElasticityRoot Canal Therapymedicine.anatomical_structureDental Prosthesis DesignGlassStress MechanicalbusinessToothDental AlloysPost and Core TechniqueOperative dentistry
researchProduct

Comparative fracture behavior of monolithic and veneered zirconia posterior fixed dental prostheses

2017

The purpose of this study was to evaluate and to compare the fracture load and the fracture pattern of monolithic and veneered zirconia posterior fixed dental prostheses (FDPs). Twenty standardized steel dies were prepared to receive posterior 3-unit FDPs. Specimens were randomly divided into 2 groups (n=10): (1) Lava Zirconia, and (2) Lava Plus. All FDPs were cemented using glass ionomer cement and subjected to thermal and mechanical cycling at 5-55ºC with a 30-s dwell time for 120,000 masticatory cycles. All specimens were subjected to a three-point bending test until fracture. Data were statistically analyzed using Student's t test, paired t-test and Weibull statistics (α=0.05). No diffe…

Dental Stress AnalysisMaterials scienceGlass ionomer cementDentistryDental Abutments02 engineering and technologyBendingVeneering ceramicDental Materials03 medical and health sciences0302 clinical medicineMaterials TestingCubic zirconiaDental Restoration FailureGeneral Dentistrybusiness.industryFracture loadMonolithic zirconia030206 dentistryStainless Steel021001 nanoscience & nanotechnologyDental VeneersGlass Ionomer CementsCeramics and CompositesFracture (geology)Computer-Aided DesignDenture Partial FixedZirconium0210 nano-technologybusinessDental Materials Journal
researchProduct

Effect of Thermomechanical and Static Loading on the Load to Fracture of Metal‐Ceramic, Monolithic and Veneered Zirconia Posterior Fixed Partial Dent…

2018

PURPOSE To evaluate the influence of static (not preloaded) and thermomechanical loading on the load to fracture of metal-ceramic, monolithic and veneered zirconia computer-aided design/computer-aided manufacturing (CAD/CAM) posterior fixed partial dentures (FPDs). MATERIALS AND METHODS One hundred standardized specimens with 2 abutments screwed onto a platform were prepared from stainless steel to receive a posterior 3-unit FPD with an intermediate pontic. Specimens were randomly divided into 5 groups (n = 20): Metal-ceramic (control group), Lava Zirconia system, Vita In-Ceram YZ, IPS e.max ZirCAD, and Lava Plus. Half of the specimens of each group (n = 10) underwent no preloading, and the…

Dental Stress AnalysisMaterials scienceMetal Ceramic AlloysDental Abutments02 engineering and technologyCrossheadDental MaterialsRandom Allocation03 medical and health sciences0302 clinical medicineMaterials TestingFixed partial denturesCubic zirconiaDental Restoration FailureComposite materialGeneral DentistryUniversal testing machineFracture loadMonolithic zirconia030206 dentistryStainless Steel021001 nanoscience & nanotechnologyMetal ceramicDental VeneersFracture (geology)Computer-Aided DesignDenture Partial FixedStress MechanicalZirconium0210 nano-technologyJournal of Prosthodontics
researchProduct

Influence of prefabricated post dimensions on restored maxillary central incisors

2007

summary  The aim of this study was to test the following hypothesis: biomechanical performance (fracture strength and stress distribution) of restored teeth is less sensitive to post diameter and post length when using glass fibre posts than when using stainless steel posts. First, an experimental fracture strength test was performed on 80 extracted human maxillary central incisors. Teeth were decoronated, treated endodontically and restored (40 with glass fibre posts and 40 with stainless steel posts), and the length and diameter of the posts varied uniformly. Failure loads were recorded and results were compared using an ancova analysis. Secondly, the finite element technique was used to …

Dental Stress AnalysisMaterials sciencebusiness.industryFinite Element AnalysisGlass fiberDentistryModels TheoreticalStress distributionStainless SteelModels DentalIncisorDental MaterialsDental Prosthesis DesignFlexural strengthMaterials TestingHumansComputer SimulationMaxillary central incisorDental Restoration FailureGlassFinite element techniquebusinessGeneral DentistryPost and Core TechniqueJournal of Oral Rehabilitation
researchProduct

Premolars restored with posts of different materials: fatigue analysis

2011

Previous works studied the effect of the material and the dimensions of the post on the biomechanical performance (fracture strength and stress distribution) of restored teeth, under static loads. The aim of this work was to study the effect of the post material (glass fibre and stainless steel) on restored teeth, which have the final crown, under dynamic conditions. The use of a biomechanical model, including a fatigue analysis from FEA, is presented as a powerful method to study the effect of the material of the intraradicular post. The inclusion of the fatigue analysis allows for a more realistic study that takes into account the dynamic nature of masticatory forces. At the same time, th…

Dental Stress AnalysisMaterials sciencemedicine.medical_treatmentGlass fiberInfluence of post materialMaterials testingCrown (dentistry)Bite ForceDental MaterialsTooth FracturesFlexural strengthMaterials TestingmedicineHumansImplant denturesBicuspidComposite materialGeneral DentistryFEAFatigueTooth NonvitalCrownsImplants dentalsRestored teethStress distributionStainless SteelFinite element methodDental Prosthesis DesignDental Stress AnalysisCeramics and CompositesBiomechanical modelGlassDental materials--FatiguePrefabricated intraradicular postsMaterials dentals--FatigaDental AlloysPost and Core Technique
researchProduct

The influence of platform switching on the biomechanical aspects of the implant-abutment system. A three dimensional finite element study

2011

Objective: To evaluate the biomechanical scenario of platform switching geometric implant-abutment configuration relative to standard configurations by means of finite element analysis.Study Design: A 3D Finite Element Analysis (FEA) was performed on 3 different implant-abutment configurations: a 3.8 mm implant with a matching diameter abutment (Standard Control Design, SCD), a 5.5 mm implant with matching diameter abutment (Wider Control Design, WCD), and a 5.5mm implant with a 3.8 mm abutment (Experimental Design, ED). All the different experimental groups were discretized to over 60000 elements and 100000 nodes, and 130N vertical (axial) and 90N horizontal loads were applied on the coron…

Dental Stress Analysisbone mechanical responseMaterials scienceimplant-abutment stresFinite Element AnalysisPlatform switchingDental Abutmentsimplant-abutment stressFinite element studyImaging Three-Dimensionalvon Mises yield criterionGeneral Dentistryplatform switchingDental Implant-Abutment Designfinite element analysis; implant-abutment stress; bone mechanical response; platform switching; implant-abutment stres:CIENCIAS MÉDICAS [UNESCO]Finite element methodBiomechanical PhenomenaStress fieldPlatform switching bone mechanical response finite element analysis implant-abutment stress.Dental Implant-Abutment DesignOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASSurgeryImplantAbutment (dentistry)Biomedical engineering
researchProduct

Measurement of gap between abutment and fixture in dental conical connection implants. A focused ion beam SEM observation

2020

Background The aim of the authors was to examine the abutment-fixture interface in Morse-type conical implants in order to verify gaps at this level using a new microscopical approach. Material and Methods In this in vitro study, 20 abutment-fixture complexes were prepared by sectioning (longitudinal and cross-sectional to the long axis) with a microtome and then with a focused ion beam (FIB). This is a micrometric machine tool that uses gallium ions to abrade circumscribed areas to dig deeper into the cuts obtained with the microtome in order to eliminate cut-induced artifacts. This is because the FIB abrasion is practically free from artifacts, which are normally generated by the action o…

Dental Stress Analysisbusiness.product_categoryMaterials scienceScanning electron microscopemicrobial leakageDental AbutmentsFixtureFocused ion beamAbrasion (geology)law.inventionSettore MED/28 - MALATTIE ODONTOSTOMATOLOGICHE03 medical and health sciences0302 clinical medicineOpticslawfocused ion beam SEMMaterials TestingMicrotomeimplant-abutment connectionGeneral DentistryDental ImplantDental Implantsbusiness.industryResearchmorse taperDental Implant-Abutment Design030206 dentistryConical surface:CIENCIAS MÉDICAS [UNESCO]Machine toolCross-Sectional StudiesOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASdental abutmentSurgerybusinessAbutment (dentistry)Implantology
researchProduct

Influence of material and diameter of pre-fabricated posts on maxillary central incisors restored with crown.

2009

Summary  Numerous research works have studied the effect of post-design parameters on the mechanical behaviour of restored teeth without reaching any clear conclusions. Previous works by the authors ascertained the effect of material and post-dimensions for non-crowned restored teeth. The aim of this work was to study the effect of post-material and diameter for crowned teeth. First, an experimental fracture strength test was performed on eighteen extracted human maxillary central incisors. Teeth were decoronated, treated endodontically and restored (nine with glass fibre posts and nine with stainless steel posts). Several post-diameters were used. The final crown restoration was carried ou…

Dental Stress Analysisinfluence of post-materialMaterials sciencemedicine.medical_treatmentGlass fiberFinite Element AnalysisDentistryCrown (dentistry)Dental Materialsstomatognathic systemFlexural strengthstress distributionMaterials TestingmedicineMaxillaHumansMaxillary central incisorDental Restoration PermanentGeneral Dentistryinfluence of post-diameterbusiness.industrybiomechanical performanceStress distributionIncisorstomatognathic diseasesDental Prosthesis DesignFracture (geology)pre-fabricated intra-radicular postsinfluence of crownFinite element techniqueGlassbusinessPost and Core TechniqueJournal of oral rehabilitation
researchProduct

A facially driven complete-mouth rehabilitation with ultrathin CAD-CAM composite resin veneers for a patient with severe tooth wear: A minimally inva…

2020

Abstract The development of technologies that include face scanning and dental software has improved workflows in dentistry. Digital files make it possible to create a 3-dimensional virtual image of the patient that helps the clinician plan treatment and make decisions, reducing uncertainty and improving communication. This report describes the complete-mouth rehabilitation of a patient with severe tooth wear. The treatment adopted a minimal intervention approach, applying adhesive veneers in areas where the tooth structure was affected and used a computer-aided design and computer-aided manufacturing (CAD-CAM) workflow to prepare nanoceramic composite resin materials with a high filler loa…

Dental softwarebusiness.industryComputer scienceMouth RehabilitationIntervention approachDentistryCAD030206 dentistryComposite ResinsDental Porcelain03 medical and health sciences0302 clinical medicineDental porcelainstomatognathic systemDental Prosthesis DesignVirtual imageTooth wearDental Prosthesis DesignComputer-Aided DesignHumansTooth WearOral SurgeryMouth RehabilitationbusinessThe Journal of prosthetic dentistry
researchProduct