Search results for "Detection limit"
showing 10 items of 810 documents
Development of a coupled diffusion denuder system combined with gas chromatography/mass spectrometry for the separation and quantification of molecul…
2009
This study concerns the development of a coupled diffusion denuder system capable of separating and quantifying gaseous molecular iodine (I(2)) and two other highly reactive iodine species, ICl and HOI, which are collectively named activated iodine compounds (AIC). Both I(2) and AIC are key species in the atmospheric chemistry of iodine. 1,3,5-Trimethoxybenzene (1,3,5-TMB)- and alpha-cyclodextrin/(129)I(-) (alpha-CD/(129)I(-))-coated denuders proved to be suitable for the collection of gaseous AIC and I(2), respectively. The experimental collection efficiencies for AIC (tested as ICl) and I(2) agreed well with the theoretical values for gas flow rates in the range between 300 and 1800 mL mi…
Extensive Evaluation of a Diffusion Denuder Technique for the Quantification of Atmospheric Stable and Radioactive Molecular Iodine
2010
In this paper we present the evaluation and optimization of a new approach for the quantification of gaseous molecular iodine (I(2)) for laboratory- and field-based studies and its novel application for the measurement of radioactive molecular iodine. alpha-Cyclodextrin (alpha-CD) in combination with (129)I(-) is shown to be an effective denuder coating for the sampling of gaseous I(2) by the formation of an inclusion complex. The entrapped (127)I(2) together with the (129)I(-) spike in the coating is then released and derivatized to 4-iodo-N,N-dimethylaniline (4-I-DMA) for gas chromatography-mass spectrometry (GC-MS) analysis. The (127)I(2) collected can be differentiated from the (129)I(-…
Chromogenic Detection of Aqueous Formaldehyde Using Functionalized Silica Nanoparticles
2016
Silica nanoparticles functionalized with thiol reactive units and bulky polar polyamines were used for the selective colorimetric detection of formaldehyde. The reaction of thiols groups in the nanoparticles surface with a squaraine dye resulted in loss of the pi-conjugation of the chromophores, and the subsequent bleaching of the solution. However, when formaldehyde was present in the suspension, the thiol-squaraine reaction was inhibited and a chromogenic response was observed. A selective response to formaldehyde was observed only when the thiol and polyamine groups were anchored to the silica surface. The observed selective response was ascribed to the fact that bulky polyamines generat…
Fast determination of prominent carotenoids in tomato fruits by CEC using methacrylate ester-based monolithic columns.
2007
In this study, the major carotenoids (beta-carotene and lycopene) present in tomato fruits were analyzed by CEC with a methacrylate ester-based monolithic column. The effects of the porogenic solvent ratio, and the hydrophobicity of bulk monomer employed were examined on carotenoids separations. A fast separation of these analytes was achieved in less than 5.0 min in a mobile phase containing 35% THF, 30% ACN, 30% methanol, and 5% of a 5 mM Tris aqueous buffer, pH 8, with lauryl methacrylate-based monoliths. The CEC method was evaluated in terms of detection limit and reproducibility (retention time, area, and column preparation) with values below 1.6 microg/mL and 7.2%, respectively. The p…
2017
Abstract. Further development and optimisation of a previously described ion trap aerosol mass spectrometer (IT-AMS) are presented, which resulted in more reproducible and robust operation and allowed for the instrument's first field deployment. Results from this 11-day-long measurement indicate that the instrument is capable of providing quantitative information on organics, nitrate, and sulfate mass concentrations with reasonable detection limits (0.5–1.4 µg m−3 for 1 h averages) and that results obtained with the IT-AMS can directly be related to those from Aerodyne aerosol mass spectrometers. The capability of the IT-AMS to elucidate the structure of fragment ions is demonstrated via an…
The catalytic-thermometric determination of molybdenum in steels based on the hydrogen peroxide-iodide indicator reaction
1990
Abstract The Mo VI -catalysed hydrogen peroxide-iodide reaction has been optimised for thermometry in an HCl medium using the initial slope method. The substitution of sodium perborate by H 2 O 2 and the conversion of the reaction to a process showing a Landolt effect are considered and discussed. The linear range extended from 0.2 μg Mo VI ml −1 to 1.2 μg Mo VI ml −1 with a detection limit of 0.06 μg Mo VI ml −1 . Interferences were also studied. The optimised procedure was applied to the evaluation of molybdenum in steels after extraction with α-benzoinoxime in chloroform.
Determination of alkylphenol ethoxylates by micellar electrokinetic chromatography with bile salts
2001
Octyl- and nonylphenol ethoxylates (OPEs and NPEs) with different numbers of ethoxy units (average values: n = 10 and N = 40 for OPEs, and n = 10 for NPEs) were separated by micellar electrokinetic chromatography under positive polarity using an 80 mM borate buffer of pH 8.5 containing sodium deoxycholate (SDC) or sodium cholate (SC). When sodium dodecyl sulfate (SDS) was added to the background electrolyte (BGE) in the absence of the bile salt, a single peak at a migration time longer than that of the EOF was obtained. Substituting the SDS by a bile salt, the homologues were resolved. At the same bile salt concentration, resolution between the homologues was higher with SDC than using SC. …
Inductively coupled plasma atomic emission spectrometric determination of arsenic in mussel products
1993
A precise, accurate procedure is proposed for the determination of arsenic in mussel products by inductively coupled plasma atomic emission spectrometry. Organic matter is destroyed by dry ashing. Experimental conditions for the determination of arsenic were selected and an interference study was carried out. The methodology developed has a detection limit of 0.1 μg g−1, a relative standard deviation of 3%, and a recovery percentage of 98±2%. The accuracy of the method was checked by analysis of a certified sample of NIST oyster tissue (certified 14.0±1.2 μg g−1; found 14.1±1.1 μg g−1). The proposed procedure was used to analyze real samples of mussel products.
In-tube solid-phase microextraction coupled by in valve mode to capillary LC-DAD: Improving detectability to multiresidue organic pollutants analysis…
2009
Abstract A simple and fast capillary chromatographic method has been developed to identify and quantify organic pollutants at sub-ppb levels in real water samples. The major groups of pesticides (organic halogens, organic phosphorous, and organic nitrogen compounds), some hydrocarbons (polycyclic aromatic hydrocarbons), phthalates and some phenols such as phenol and bisphenol A (endocrine disruptors) were included in this study. The procedure was based on coupling, in-tube solid-phase microextraction (IT-SPME) by using a conventional GC capillary column (95% methyl–5% phenyl substituted backbone, 80 cm × 0.32 mm i.d., 3 μm film thickness) in the injection valve to capillary liquid chromatog…
Method for determination of formaldehyde in air in the pptv-range by HPLC after extraction as 2,4-dinitrophenyl-hydrazone
1982
The derivatization of formaldehyde with 2,4-dinitrophenylhydrazine and the extraction of the product formalhydrazone is studied. The determination is carried out by HPLC. Applying a cryogenic sampling technique and a sampling volume of 300l of air the detection limit of formaldehyde in air is 30 pptv and this is suitable for measurements of formaldehyde in the atmosphere. (IFU)