Search results for "Detectors"
showing 10 items of 2229 documents
Diagnostics of capillary mercury–argon high-frequency electrodeless discharge using line shapes
2005
Abstract The profiles of the 253.7 nm spectral line, emitted from the capillary argon–mercury isotope high-frequency electrodeless discharge, are measured by means of a pressure-scanned Fabry–Perot spectrometer. Spectral line profiles are collected from two lamps at the argon pressure of 2 and 10 Torr, in dependence on the discharge current and Hg vapor densities corresponding to the cold spot temperatures of 25–80 °C. By means of a multi-parameter non-linear line profile fitting procedure of multiple overlapping self-reversed Voigt profiles, the temperature of the radiating atoms and the optical density were estimated. The capillary and spherical discharge conditions were compared. The opt…
The Miniball spectrometer
2013
The Miniball germanium detector array has been operational at the REX (Radioactive ion beam EXperiment) post accelerator at the Isotope Separator On-Line facility ISOLDE at CERN since 2001. During the last decade, a series of successful Coulomb excitation and transfer reaction studies have been performed with this array, utilizing the unique and high-quality radioactive ion beams which are available at ISOLDE. In this article, an overview is given of the technical details of the full Miniball setup, including a description of the γ-ray and particle detectors, beam monitoring devices and methods to deal with beam contamination. The specific timing properties of the REX-ISOLDE facility are hi…
The SPEDE spectrometer
2017
8 pags., 10 figs., 2 tabs.
A new off-line ion source facility at IGISOL
2019
An off-line ion source station has been commissioned at the IGISOL (Ion Guide Isotope Separator On-Line) facility. It offers the infrastructure needed to produce stable ion beams from three off-line ion sources in parallel with the radioactive ion beams produced from the IGISOL target chamber. This has resulted in improved feasibility for new experiments by offering reference ions for Penning-trap mass measurements, laser spectroscopy and atom trap experiments.
Twin GEM-TPC prototype (HGB4) beam test at GSI and Jyväskylä : a development for the Super-FRS at FAIR
2017
The FAIR[1] facility is an international accelerator centre for research with ion and antiproton beams. It is being built at Darmstadt, Germany as an extension to the current GSI research institute. One major part of the facility will be the Super-FRS[2] separator, which will be include in phase one of the project construction. The NUSTAR experiments will benefit from the Super-FRS, which will deliver an unprecedented range of radioactive ion beams (RIB). These experiments will use beams of different energies and characteristics in three different branches; the high-energy which utilizes the RIB at relativistic energies 300-1500 MeV/u as created in the production process, the low-energy bra…
The SPEDE Spectrometer: Combined In-Beam γ-ray and Conversion Electron Spectroscopy with Radioactive Ion Beams
2015
The SPEDE spectrometer [1] aims to combine a silicon detector, for the detection of electrons, with the MINIBALL γ-ray detection array for in-beam studies employing radioactive ion beams at the HIE-ISOLDE facility at CERN. The setup will be primarily used for octupole collectivity [2] and shape coexistence studies [3, 4] in Coulomb excitation experiments. In the shape coexistence cases the transitions between states of the same spin and parity have enhanced E0 strength [5]. Additionally the 0→0 transitions, typically present in nuclei exhibiting shape coexistence [6], can only occur via E0 transitions, i.e. via internal conversion electron emission.
Mechanically stable metal layers for ohmic and blocking contacts on CdZnTe detectors by electroless deposition
2015
CdZnTe detectors are commonly exploited for the detection of gamma rays. However, obtaining mechanical stable, low noise contacts on CdZnTe is still an issue. In particular, ohmic contacts would be preferable for high flux applications. In this work, we show that it is possible to obtain mechanical stable gold contacts by electroless deposition in methanol solution. Moreover, we show that electroless deposited nickel contacts are also mechanical stable and are good candidates for the realization of ohmic contacts on high resistivity CdZnTe crystals.
Charge carrier transport mechanisms in CdZnTe detectors grown by the vertical Bridgman technique
2016
In this work, we report on the results of electrical characterization of CdZnTe (CZT) detectors, with gold electroless contacts, grown by the boron oxide encapsulated vertical Bridgman technique (B-VB), currently produced at IMEM-CNR (Parma, Italy). The detectors, with different thicknesses (1 and 2.5 mm), have the same electrode layout: the anode is a central electrode (2 x 2 mm(2)) surrounded by a guard ring electrode. The cathode is a planar electrode covering the detector surface (4.1 x 4.1 mm(2)). Current-voltage (I-V) characteristics were measured at different temperatures in order to study the charge transport and the electrical properties. These detectors were compared with the trav…
Digital CZT detector system for high flux energy-resolved X-ray imaging
2017
Photon counting arrays with energy resolving capabilities are recently desired for the next-generation X-ray imaging systems. In this work, we present the performance of a 2 mm thick CZT pixel detector, with pixel pitches of 500 mu m and 250 mu m, coupled to a fast and low noise ASIC (PIXIE ASIC), characterized by only the preamplifier stage. A 16-channel digital readout electronics was used to continuously digitize and process each output channel from the PIXIE ASIC, performing multi-parameter analysis (event arrival time, pulse shape, pulse height) at low and high input counting rates (ICRs). The spectroscopic response of the system to monochromatic X-ray and gamma ray sources, at both lo…
Radon and material radiopurity assessment for the NEXT double beta decay experiment
2015
Artículo escrito por un elevado número de autores, solo se referencian el que aparece en primer lugar, el nombre del grupo de colaboración, si le hubiere, y los autores pertenecientes a la UAM