Search results for "Diagnostica"
showing 10 items of 607 documents
Hepatocellular carcinoma in cirrhotic patients at multidetector CT: hepatic venous phase versus delayed phase for the detection of tumour washout.
2011
OBJECTIVES: Our aim was to compare retrospectively hepatic venous and delayed phase images for the detection of tumour washout during multiphasic multidetector row CT (MDCT) of the liver in patients with hepatocellular carcinoma (HCC). METHODS: 30 cirrhotic patients underwent multiphasic MDCT in the 90 days before liver transplantation. MDCT was performed before contrast medium administration and during hepatic arterial hepatic venous and delayed phases, images were obtained at 12, 55 and 120 s after trigger threshold. Two radiologists qualitatively evaluated images for lesion attenuation. Tumour washout was evaluated subjectively and objectively. Tumour-to-liver contrast (TLC) was measured…
Diagnostic value of MR-based texture analysis for the assessment of hepatic fibrosis in patients with nonalcoholic fatty liver disease (NAFLD)
2019
PurposeTo investigate the performance of MR-based texture analysis (TA) for the assessment of hepatic fibrosis in patients with nonalcoholic fatty liver disease (NAFLD).MethodsFifty-four adult patients (33 females, 21 males, mean age 49.813.5years) with biopsy-proven NAFLD were enrolled and underwent MR imaging on a 1.5T system. TA parameters were extracted on axial noncontrast 3D-GRE T1W images (slice thickness=4.6mm) using a commercially available research software (TexRAD). Receiver operating curves (ROC), areas under the ROC (AUROC) and 95% confidence intervals (CI) were calculated to assess the accuracy of each TA parameter for the diagnosis of significant (F2) and advanced fibrosis (F…
A semi-automatic approach for epicardial adipose tissue segmentation and quantification on cardiac CT scans
2019
Abstract Many studies have shown that epicardial fat is associated with a higher risk of heart diseases. Accurate epicardial adipose tissue quantification is still an open research issue. Considering that manual approaches are generally user-dependent and time-consuming, computer-assisted tools can considerably improve the result repeatability as well as reduce the time required for performing an accurate segmentation. Unfortunately, fully automatic strategies might not always identify the Region of Interest (ROI) correctly. Moreover, they could require user interaction for handling unexpected events. This paper proposes a semi-automatic method for Epicardial Fat Volume (EFV) segmentation a…
Evaluation of texture analysis for the differential diagnosis of focal nodular hyperplasia from hepatocellular adenoma on contrast-enhanced CT images
2018
PurposeTo explore the value of CT texture analysis (CTTA) for differentiation of focal nodular hyperplasia (FNH) from hepatocellular adenoma (HCA) on contrast-enhanced CT (CECT).MethodsThis is a retrospective, IRB-approved study conducted in a single institution. A search of the medical records between 2008 and 2017 revealed 48 patients with 70 HCA and 50 patients with 62 FNH. All lesions were histologically proven and with available pre-operative CECT imaging. Hepatic arterial phase (HAP) and portal venous phase (PVP) were used for CTTA. Textural features were extracted using a commercially available research software (TexRAD). The differences between textural parameters of FNH and HCA wer…
Computed tomography coronary angiography in asymptomatic patients
2011
This study assessed the accuracy of computed tomography coronary angiography (CT-CA) for detecting significant coronary artery disease (CAD; a parts per thousand yen50% lumen reduction) in intermediate/high-risk asymptomatic patients. A total of 183 consecutive asymptomatic individuals (92 men; mean age 54 +/- 11 years) with more than one major risk factor (obesity, hypertension, diabetes, hypercholesterolaemia, family history, smoking) and an inconclusive or nonfeasible noninvasive stress test result (stress electrocardiography, stress echocardiography, nuclear stress scintigraphy) underwent CT-CA in an outpatient setting. All patients underwent conventional coronary angiography (CAG) with…
Three-dimensional (3D) versus two-dimensional (2D) laparoscopic adrenalectomy: A case-control study
2016
Abstract Introduction Laparoscopic adrenalectomy is today considered the gold standard of treatment for adrenal tumors. The development of high definition cameras does not eliminate the major limitation of two-dimensional (2D) laparoscopy: lack of depth perception and loss of spatial orientation. Tree-dimensional (3D) HD laparoscopy was developed as an alternative to conventional 2D laparoscopy. Methods We report our experience with use of 3D vision system for laparoscopic adrenalectomy. Between January 2009 and March 2015 we performed a total of 52 laparoscopic adrenalectomies. In this case-control study we considered 13 laparoscopic adrenalectomies performed with three-dimensional (3D) vi…
Utility of CT in the diagnosis of pancreatic fistula after pancreaticoduodenectomy in patients with soft pancreas.
2009
OBJECTIVE: The purpose of this study was to evaluate the sensitivity and specificity of routine performance of CT on postoperative day 7 in patients at high risk of pancreatic fistula after pancreaticoduodenectomy. MATERIALS AND METHODS: Two radiologists analyzed images from CT examinations of 50 patients with soft pancreas 7 days after pancreaticoduodenectomy. Pancreatic fistula was defined at CT as a fluid collection close to the pancreaticogastric or pancreaticojejunal anastomosis. Clinicobiologic criteria for the diagnosis of pancreatic fistula were drain output of any measurable volume of fluid on or after postoperative day 3 that had an amylase content more than three times the serum …
Adult exposures from MDCT including multiphase studies: first Italian nationwide survey.
2014
To evaluate the radiation dose in routine multidetector computed tomography (MDCT) examinations in Italian population.This was a retrospective multicentre study included 5,668 patients from 65 radiology departments who had undergone common CT protocols: head, chest, abdomen, chest–abdomen–pelvis (CAP), spine and cardiac. Data included patient characteristics, CT parameters, volumetric CT dose index (CTDIvol) and dose length product (DLP) for each CT acquisition phase. Descriptive statistics were calculated, and a multi-regression analysis was used to outline the main factors affecting exposure.The 75th percentiles of CTDIvol (mGy) and DLP (mGy cm) for whole head were 69 mGy and 1,312 mGy cm…
Analysis of the correlations between oxidative stress, gelatinases and their tissue inhibitors in the human subjects with obstructive sleep apnea syn…
2015
Obstructive sleep apnea syndrome (OSAS) is commonly associated with endothelial dysfunction, atherosclerosis and cardiovascular disorders. On the basis of this observation, our aim was to examine the oxidative status and the matrix metalloproteases (MMP) profile in a group of subjects with OSAS. We enrolled 48 subjects with OSAS defined after a 1-night cardiorespiratory sleep study, who were subsequently subdivided in two subgroups according to the severity of OSAS (low grade = L-OSAS; high grade= H-OSAS). We measured the parameters of oxidative stress, such as lipid peroxidation, protein oxidation, total antioxidant status (TAS), nitric oxide metabolites (NOx), and the plasma concentration…
Efficacy of single-source rapid kV-switching dual-energy CT for characterization of non-uric acid renal stones: a prospective ex vivo study using ant…
2019
Purpose To investigate the accuracy of rapid kV-switching single-source dual-energy computed tomography (rsDECT) for prediction of classes of non-uric-acid stones. Materials and methods Non-uric-acid renal stones retrieved via percutaneous nephrolithotomy were prospectively collected between January 2017 and February 2018 in a single institution. Only stones >= 5 mm and with pure composition (i.e., >= 80% composed of one component) were included. Stone composition was determined using Fourier Transform Infrared Spectroscopy. The stones were scanned in 32-cm-wide anthropomorphic whole-body phantom using rsDECT. The effective atomic number (Zeff), the attenuation at 40 keV (HU40), 70 ke…