Search results for "Diaphysis"

showing 2 items of 12 documents

Bone-Healing Pattern on the Surface of Titanium Implants at Cortical and Marrow Compartments in Two Topographic Sites: an Experimental Study in Rabbi…

2018

This study evaluates the bone-healing patterns on the surface of titanium implants at the cortical and marrow compartments of bicortically-installed implants in the diaphysis and metaphysis of rabbit tibiae. In 27 New Zealand rabbits, two implants, one for each macro-design and with equal resorbable blasted media (RBM) implant surfaces, were randomly implanted in the diaphysis or metaphysis of each tibia. The flaps were sutured to allow submerged healing. The animals were sacrificed after two, four, or eight weeks, with nine weeks used for the period of healing. Ground sections were prepared and analyzed. No statistically significant differences were found between the two groups for newly f…

implant macro-designmedicine.medical_treatment02 engineering and technologyBone healingMetaphysislcsh:TechnologyArticleOsseointegration03 medical and health sciences0302 clinical medicinemedicineGeneral Materials ScienceTibiaDental implantlcsh:Microscopylcsh:QC120-168.85dental implantlcsh:QH201-278.5Chemistrylcsh:Tosseointegration030206 dentistryAnatomy021001 nanoscience & nanotechnologyanimal studyDiaphysisAppositionmedicine.anatomical_structurelcsh:TA1-2040bicortical stabilizationlcsh:Descriptive and experimental mechanicsImplantlcsh:Electrical engineering. Electronics. Nuclear engineering0210 nano-technologylcsh:Engineering (General). Civil engineering (General)lcsh:TK1-9971Materials
researchProduct

Minimally invasive plate fixation in femoral shaft fractures

1997

Bridge-plating with its advantages in terms of vascularity and bone healing is a well established procedure today in the treatment of comminuted femoral fractures. Bridge-plating means that the fracture site is not interfered with during the operative procedure. This paper introduces a surgical technique in which the plate is inserted through isolated proximal and distal incisions only, behind the vastus lateralis. Alignment is secured by the plates, the fracture site remains untouched, fixation and screw insertion is restricted to the proximal and distal main fragments. Longitudinal femoral fractures extending right into the trochanteric and or condylar areas are the main indication for mi…

medicine.medical_specialtyBone healingCondyleFracture Fixation InternalVascularitymedicineHumansMinimally Invasive Surgical ProceduresFemurFractures ComminutedGeneral Environmental ScienceFracture HealingOsteosynthesisbusiness.industrySoft tissuemusculoskeletal systemSurgeryRadiographyDiaphysismedicine.anatomical_structureOrthopedic surgeryGeneral Earth and Planetary SciencesFemalemedicine.symptombusinessBone PlatesFemoral FracturesFollow-Up StudiesInjury
researchProduct