Search results for "Difference"

showing 10 items of 1534 documents

Effect of cusp coverage and water storage on compressive strength of composite restorations of premolars

2018

Background The aim of this study was to assess the effect of cusp coverage and water storage on compressive strength of composite restorations. Material and Methods This in vitro experimental study was conducted on 40 extracted human maxillary premolar teeth, which were randomly divided into four groups of 10. Mesio-occluso-distal (MOD) cavities were prepared in all teeth. The thickness of composite for cusp coverage was 1.5 mm in groups 1 and 3 and 2.5 mm in groups 2 and 4. Compressive strength (CS) was measured after 24 hours in groups 1 and 2 and after six months of water storage in groups 3 and 4. Two-way ANOVA was used to statistically analyze the data. Results The mean and standard er…

OrthodonticsMaterials scienceAbsorption of waterResearchSignificant differenceComposite number02 engineering and technology:CIENCIAS MÉDICAS [UNESCO]010402 general chemistry021001 nanoscience & nanotechnology01 natural sciencesOperative Dentistry and Endodontics0104 chemical sciencesmedicine.anatomical_structureCompressive strengthFlexural strengthUNESCO::CIENCIAS MÉDICASPremolarmedicineCusp (anatomy)Statistical analysis0210 nano-technologyGeneral Dentistry
researchProduct

Effect of over-the-counter whitening strips and toothpaste on shear bond strength of orthodontic brackets

2021

Background To investigate: 1) the effects of over-the-counter white strip enamel bleaching and 2-Step whitening toothpaste application on the shear bond strength of orthodontic brackets at 24-hours and 7-days post-bleaching latent period; and 2) the correlation between amount of bleaching and shear bond strength. Material and Methods Sixty human premolar teeth were randomly assigned into two bleaching groups, white strip group treated with Crest® 3D WHITE™ LUXE Professional Effects Whitestrips (Proctor & Gamble, Greensboro, NC), and whitening toothpaste group, treated with Crest® 3D WHITE™ BRILLIANCE 2-Step Toothpaste (Proctor & Gamble, Greensboro, NC). The groups were further divided into …

OrthodonticsMaterials scienceToothpastebusiness.product_categoryEnamel paintResearchSignificant differenceOrthodonticsShear bondOrthodontic bracketsmedicine.anatomical_structureColor changesvisual_artPremolarmedicinevisual_art.visual_art_mediumsense organsbusinessGeneral DentistryUNESCO:CIENCIAS MÉDICAS
researchProduct

Impact of chronic allergic rhinitis on bite force and electromyographic activity of masseter and temporalis muscles of adult women

2020

Background The aim of this study was to analyse the stomatognathic system of adult women with chronic allergic rhinitis by means of molar bite force and electromyographic activity of the masseter and temporalis muscles. Material and Methods A total of 26 subjects were screened and divided into two distinct groups: chronic allergic rhinitis group (n = 13) and healthy control group (n = 13). Subjects were assessed by maximal molar bite force (right and left) and normalized electromyographic activity of mandibular tasks (rest, right and left laterality, protrusion and maximal voluntary contraction). Data were submitted to Student's t test (p< .05). Results There was significant difference in r…

OrthodonticsMolarOral Medicine and Pathologymedicine.diagnostic_testbusiness.industryResearchSignificant differenceElectromyography:CIENCIAS MÉDICAS [UNESCO]Masticatory forceAdult womenBite force quotientStomatognathic systemLateralityUNESCO::CIENCIAS MÉDICASMedicinebusinessGeneral DentistryJournal of Clinical and Experimental Dentistry
researchProduct

Orthodontists? preference on type of rigid fixed functional appliance for skeletal Class II correction : a survey study

2020

Background Rigid fixed functional appliances are most commonly used to correct skeletal Class II malocclusions. The objective of this study was to assess orthodontists' preference of different rigid fixed functional appliances used in the U.S.A for correction of skeletal Class II malocclusions. Material and methods A survey on use and preference of rigid fixed functional appliances for skeletal Class II correction was emailed to 2,227 members of the American Association of Orthodontists (AAO) in the U.S.A. Frequency distribution of different responses and their association with demographic factors was assessed. Results Out of 140 orthodontists completing the survey, 110 responded as using r…

OrthodonticsMolarbusiness.industryResearchSignificant differenceSurvey researchOrthodonticsHerbst ApplianceSkeletal classmedicine.disease:CIENCIAS MÉDICAS [UNESCO]Mandibular retrognathismAge groupsUNESCO::CIENCIAS MÉDICASMedicineMalocclusionbusinessGeneral Dentistry
researchProduct

Understanding the role of osteoarthrosis on electromyographic activity of masticatory muscles and quality of life

2019

Background Osteoarthrosis is a severe, evolutionary, chronic, and limiting disease that influences on quality of life, as it affects synovial joints and promoted degradation of hyaline articular cartilage. We sought to determine if electromyographic activity of the masticatory muscles and quality of life are negatively impacted by osteoarthrosis. Material and Methods A sample of 72 participants between 40 and 70 years old diagnosed with osteoarthrosis were selected. Forty-eight participants met the inclusion criteria of this study and were divided into two distinct groups: with osteoarthrosis (n=24) and without osteoarthrosis (n=24). Electromyographic activity of the masseter and temporalis…

OrthodonticsOral Medicine and Pathologybusiness.industryResearchSignificant differenceMuscle activation:CIENCIAS MÉDICAS [UNESCO]Temporal muscleMasticatory forceMasseter muscleQuality of lifeUNESCO::CIENCIAS MÉDICASLateralityMedicinebusinessGeneral DentistryHyalineJournal of Clinical and Experimental Dentistry
researchProduct

Customised pressure profiles of made-to-measure sports compression garments

2021

AbstractThe purpose of this study was to make made-to-measure compression garments that elicit pressures within and below clinical standards. The study also examined whether pressures and gradients can be replicated within and between participants’ legs, and between separate compression garment conditions. Ten males volunteered to participate. Based on three-dimensional scans of the participants’ lower body, three different made-to-measure garments were manufactured: control, symmetrical and asymmetrical. Garment pressures were assessed from the malleolus to the gluteal fold using a pressure monitoring device. A root mean squared difference analysis was used to calculate the in vivo linear …

OrthodonticsPressure reductionbusiness.industryMechanical EngineeringPeak pressureBiomedical EngineeringPhysical Therapy Sports Therapy and Rehabilitation030229 sport sciencesCompression garmentCompression (physics)Malleolus03 medical and health sciences0302 clinical medicineLower bodymedicine.anatomical_structureMechanics of MaterialsModeling and SimulationDifference analysisMedicineOrthopedics and Sports MedicineAnklebusiness030217 neurology & neurosurgery
researchProduct

Evaluation of accuracy of various impression techniques and impression materials in recording multiple implants placed unilaterally in a partially ed…

2018

Background Various factors like implant angulation, type of impression material and tray type affects the implant impression accuracy. To date limited in-vitro studies were carried out on the implant impression accuracy of unilateral partially edentulous arches. The aim of this research was to evaluate the effects of 0o, 15o and 25o implant angulations on impression accuracy in simulated master casts of unilateral partially edentulous situation using different impression materials and tray selections. Material and Methods 30 replicas (N = 30) of a resin matrix (control) containing four implant analogues placed unilaterally from the midline till the region of second molar at an angulation of…

OrthodonticsProsthetic DentistryResearchSignificant differenceSmall sample030206 dentistry:CIENCIAS MÉDICAS [UNESCO]ImpressionMandibular second molar03 medical and health sciences0302 clinical medicineTrayUNESCO::CIENCIAS MÉDICASIn vitro study030212 general & internal medicineImplantPartially edentulous mandibleGeneral DentistryMathematics
researchProduct

Are different generations of CAD/CAM milling machines capable to produce restorations with similar quality?

2016

Background: Different CAD/CAM machinesâ generation may impact the restoration overall quality. The present study evaluated the marginal fit of CAD/CAM restorations manufactured with different generations of CEREC milling unit systems. Material and Methods: Sixteen typodont teeth were divided into two groups (n=8) according to the machineâ s generation assigned. These are control group (G1): Cerec AC with Bluecam/Cerec 3 milling unit and (G2): Cerec AC with Bluecam/MC XL Premium Package milling unit. Scanning of the preparation were performed and crowns were milled using the Vita Mark II blocks. Blocks were cemented using epoxy glue on the pulpal floor only and finger pressure applied for 1 …

OrthodonticsProsthetic DentistryTypodontResearch05 social sciencesStatistical differenceCADOdontología030206 dentistryCiencias de la salud03 medical and health sciences0302 clinical medicineCEREC0502 economics and businessFinger pressureUNESCO::CIENCIAS MÃ DICAS050211 marketing:CIENCIAS MÃ DICAS [UNESCO]General DentistryAbutment (dentistry)Mathematics
researchProduct

The accuracy of the Raypex5 electronic apex locator using stainless-steel hand K-file versus nickel-titanium rotary Mtwo file

2009

Objectives: Today many clinicians use both stainless-steel hand K-files and nickel- titanium rotary files during endodontic treatment. It is of great importance for the clinician to have confidence in the accuracy of an apex locator even if these files were used interchangeably. The purpose of this in-vitro study was to evaluate the accuracy of the Raypex5 electronic apex locator using stainless-steel hand K-file versus nickel-titanium rotary Mtwo file. Study design: Twenty straight and single canals of maxillary central teeth were used. Access cavities were prepared; actual working length were determined and compared with electronic working length obtained by means of apex locator Raypex5 …

OrthodonticsTitaniumElectronic apex locatorComputer scienceSignificant differencefungitechnology industry and agricultureReproducibility of ResultsIn Vitro Techniques:CIENCIAS MÉDICAS [UNESCO]Stainless SteelRoot Canal TherapyOtorhinolaryngologyTooth ApexNickel titaniumNickelUNESCO::CIENCIAS MÉDICASHumansSurgeryGeneral Dentistry
researchProduct

Can tongue position and cervical ROM affect postural oscillations? A pilot and preliminary study

2020

The tongue is considered an important part of the postural system, so it is fundamental to understand how it can interfere with the humans’ postural oscillations. The aim of this preliminary investigation is to understand the effects of different tongue position and cervical ROM on postural oscillations measured in a stabilometric test. Thirteen voluntary subjects were recruited (30.8 ± 9.7 yrs.; 173.6 ± 14.9 cm; 72.6 ± 15.6 kg) and tested in three different random tongue conditions: comfortable tongue position (CT), palatal spot position (ST) and low tongue position (LT). All tests were performed with open eyes. Stabilometric test were performed with a pressure platform. In addition, the c…

OrthodonticsTongue positionbusiness.industrySignificant differencePostureStabilometryPosition (obstetrics)medicine.anatomical_structureCervical ROMPostural oscillationsTongueEducación Física y DeportivaMedicineTongue conditionsbusiness
researchProduct