Search results for "Discharge"
showing 10 items of 424 documents
Optical techniques for river flow monitoring: an automatic procedure for the identification of the best video sequence to process by LS-PIV technique
2022
Technological advances over last decades gave an innovative impulse to the development of new streamflow measurements techniques, especially regarding remote flow monitoring methods that allow for non-intrusive measurements. The most widely used image-based techniques are the optical ones, such as Large-Scale Particle Image Velocimetry (LS-PIV) and Large-Scale Particle Tracking Velocimetry (LS-PTV). The dynamic movement of tracers floating on the water surface of a river is recorded, and the resulting videos are processed by applying a statistical cross-correlation analysis to detect the most probable frame-by-frame displacement, finally deriving the surface velocity field. To obtain river …
Volcano seismicity and ground deformation unveil the gravity-driven magma discharge dynamics of a volcanic eruption.
2015
Effusive eruptions are explained as the mechanism by which volcanoes restore the equilibrium perturbed by magma rising in a chamber deep in the crust. Seismic, ground deformation and topographic measurements are compared with effusion rate during the 2007 Stromboli eruption, drawing an eruptive scenario that shifts our attention from the interior of the crust to the surface. The eruption is modelled as a gravity-driven drainage of magma stored in the volcanic edifice with a minor contribution of magma supplied at a steady rate from a deep reservoir. Here we show that the discharge rate can be predicted by the contraction of the volcano edifice and that the very-long-period seismicity migrat…
Multipactor Discharges in Parallel-Plate Dielectric-Loaded Waveguides Including Space-Charge Effects
2008
[EN] The objective of this paper is to study the time evolution of multipactor discharges in a parallel-plate dielectric-loaded waveguide. The electron discharge phenomena investigated in this paper include the effects of space charge, as well as the presence of time varying static fields. In order to perform the simulations presented in this paper, an approach considering simultaneously multiple effective electrons has been used. The results obtained demonstrate that multipactor discharges do turn off by themselves under certain circumstances when they occur in such dielectric-loaded structures.
Time evolution of an electron discharge in a parallel-plate dielectric-loaded waveguide
2006
The objective of this letter is to study the time evolution of a multipactor discharge in a simple dielectric waveguide structure. In particular, the investigation is performed on the case of a parallel-plate waveguide structure partially filled with a dielectric layer. The main consequence of the specific case studied in this letter is the fact that the dielectric layer charges negatively, allowing a negative static field to build up. This dc field eventually leads to a single-surface multipactor in the metallic surface before finally turning off the electron discharge.
An analytical model to evaluate the radiated power spectrum of a multipactor discharge in a parallel-plate region
2008
This paper is aimed at studying the electromagnetic radiation pattern of a multipactor discharge occurring in a parallel-plate waveguide. The proposed method is based on the Fourier expansion of the multipactor current in terms of time-harmonic currents radiating in the parallel-plate region. Classical radiation theory combined with the frequency domain Green's function of the problem allows the calculation of both the electric and the magnetic radiated fields. A novel analytical formula for the total radiated power of each multipactor harmonic has been derived. This formula is suitable for predicting multipactor with the third-harmonic technique. The proposed formulation has been successfu…
Temporal variability analysis reveals biases in electronic health records due to hospital process reengineering interventions over seven years
2019
[EN] Objective To evaluate the effects of Process-Reengineering interventions on the Electronic Health Records (EHR) of a hospital over 7 years. Materials and methods Temporal Variability Assessment (TVA) based on probabilistic data quality assessment was applied to the historic monthly-batched admission data of Hospital La Fe Valencia, Spain from 2010 to 2016. Routine healthcare data with a complete EHR was expanded by processed variables such as the Charlson Comorbidity Index. Results Four Process-Reengineering interventions were detected by quantifiable effects on the EHR: (1) the hospital relocation in 2011 involved progressive reduction of admissions during the next four months, (2) th…
The effect of experimental and clinical musculoskeletal pain on spinal and supraspinal projections to motoneurons and motor unit properties in humans…
2021
Background and Objective Numerous studies have examined the influence of pain on spinal reflex excitability, motor unit behaviour and corticospinal excitability. Nevertheless, there are inconsistencies in the conclusions made. This systematic review sought to understand the effect of pain on spinal and supraspinal projections to motoneurons and motor unit properties by examining the influence of clinical or experimental pain on the following three domains: H-reflex, corticospinal excitability and motor unit properties. Databases and Data Treatment MeSH terms and preselected keywords relating to the H-reflex, motor evoked potentials and motor unit decomposition in chronic and experimental pa…
Electric strength, space charge and surface discharge characterization of nanostructured epoxy-silicate insulating materials
2005
A set of surface discharge ageing procedures, space charge observations and dielectric strength measurements has been implemented on a type of insulating nanofilled epoxy-resin (nanostructured by compatibilised synthetic layered silicates) and on its non-filled base resin. Promising improvements in the electrical behaviour of the nanofilled epoxy, particularly as concerns surface discharge endurance, were detected. Regarding space charge, it was found that its accumulation rate as a function of ageing time is lower for the nanostructured resin. Finally, the nanofilled material evidenced a highly homogeneous behaviour of the dielectric strength data distribution.