Search results for "Discharge"
showing 10 items of 424 documents
Power Bus Management Techniques for Space Missions in Low Earth Orbit
2021
In space vehicles, the typical configurations for the Solar Array Power Regulators in charge of managing power transfer from the solar array to the power bus are quite different from the corresponding devices in use for terrestrial applications. A thorough analysis is reported for the most popular approaches, namely Sequential Switching Shunt Regulation and parallel-input Pulse Width Modulated converters with Maximum Power Point Tracking. Their performance is compared with reference to a typical mission in low Earth orbit, highlighting the respective strengths and weaknesses. A novel solar array managing technique, the Sequential Maximum Power Tracking, is also introduced in the trade-off a…
Efficacy of coronary revascularization in patients with acute chest pain managed in a chest pain unit.
2009
To investigate the safety of discharge of patients deemed at low risk of cardiac events after evaluation in a chest pain unit and to determine the prognostic effect of revascularization of patients deemed at high risk.The study population consisted of 1088 patients presenting at the emergency department from January 15, 2001, to September 1, 2006, with chest pain but without ischemia on electrocardiography or troponin elevation. Patients were managed by a chest pain unit protocol that included early exercise testing. Three groups of patients were distinguished: (1) those discharged after exercise testing (424 [39%]); (2) those in whom unstable angina was ruled out after in-hospital evaluati…
Determining Probability Distribution of Hillslope Peak Discharge by Using an Analytical Solution of Kinematic Wave Time of Concentration.
2016
Hillslope hydrology is fundamental for understanding the flood phenomenon and for evaluating the time of concentration. The latter is a key variable for predicting peak discharge at the basin outlet and for designing urban infrastructure facilities. There have been a multitude of studies on the hydrologic response at the hillslope scale, and the time of concentration has been derived for different approaches. One approach for deriving hillslope response utilizes, in a distributed form, the differential equations of unsteady overland flow, specifically developed at the hydrodynamic scale, in order to account for the spatial heterogeneity of soil characteristics, topography, roughness and veg…
Tomographic diagnostics of high-frequency electrodeless lamps in argon–mercury mixtures
2006
Tomographic reconstruction of spatial profiles of the mercury atom density in the excited state 7 3S1 in high-frequency electrodeless lamps (HFELs) has been performed. The measurements of the Hg 546.1 nm line emission intensity have been made for the HFELs in argon–mercury mixture depending on the operation regime with different cold spot temperatures in the range 31–98 °C. The maximum entropy-based algorithm was applied for the reconstruction of local emission coefficients from the integrated intensities. The emission coefficients are directly related to the local values of the mercury atom density in the excited state 7 3S1, the upper state of the 546.1 nm transition. Such an investigatio…
Portable central baffle flume
2022
This paper investigated the hydraulic characteristics of the triangular central baffle (TCB) flume. Laboratory tests were carried out to determine the flume dimensions. The field applicability of the proposed portable device was examined by on-farm installation. According to the laboratory tests, when the contraction ratio, r, was less than 0.39, the flow capacity was not affected by the ratio between the flume’s floor height and the throat width. The laboratory analysis also showed that there was no significant effect of installing an entrance ramp on the stage-discharge relationship for r<0.39, while the entrance ramp increased the discharge capacity for r>0.39. The stage-discharge …
Radiometric Partial Discharge Detection: A Review
2023
One of the most common failures or breakdowns that can occur in high-voltage (HV) equipment is due to partial discharges (PDs). This occurs as a result of inadequate insulation, aging, harsh environmental effects, or manufacturing flaws. PD detection and recognition methods have gained growing attention and have seen great progress in the past decades. Radiometric methods are one of the most investigated detection approaches due to their immunity to electromagnetic interference (EMI) and their capabilities to detect and locate PD activities in different applications such as transformers, cables, etc. Several review articles have been published to classify and categorize these works. Nonethe…
Complex Rating Curves for Sharp Crested Orifices and Rectangular or Triangular Weirs under Unsteady Flow Conditions
2021
The importance of discharge measurements is fully acknowledged in many research fields, mostly in hydrology. Numerous measurement devices and various overflow structures have been proposed for discharge measurements; however, their use is based on calibrated simple stage discharge relationships that may cause significant errors when unsteady flow conditions occur. This issue is quite common because of rainfall and runoff temporal variability that inhibits the achievement of the steady state. Although this issue has already been experimentally investigated, it seems that a physically based line of approach has not been attempted before. In this paper, unsteady stage discharge relationships o…
Balansen mellom kontekstuelle krav og pasientenes behov : ergoterapeuters erfaringer knyttet til eldre pasienters overgangsfase fra sykehus til eget …
2014
Background and aim: Coping in daily activities when discharged from hospital to own home can be challenging for older people. Internationally, there is a number of studies on this topic, but similar studies in Norway and Nordic countries seem to be scarce. The aim of this study was to illuminate occupational therapists’ experiences of how to promote coping of daily activities in older patients who are discharged from hospital to home. Methods: A qualitative design with individual interviews was used. A purposive sample of eight occupational therapists were included, four worked in hospitals and four in community health services, respectively. Initially the interviews had an open form, but a…
Mesh complications following prolapse surgery: management and outcome.
2011
Abstract Objective This is a description of complications following prolapse surgery with the use of alloplastic materials, the management and outcome. Study design 54 women have been referred to Mainz, urogynecology referral center due to complications following mesh-augmented prolapse surgery. Results The complaints who lead to the admission are expressed by the new terminology and standardized classification for complications arising directly from the insertion of prostheses and grafts in female pelvic floor surgery [1] . Pain (66.7%), mesh erosion (55.6%) and vaginal discharge (48.1%) were the most frequent complaints. Revision was performed after a median time of 27.2 months post mesh …
Female genital schistosomiasis--a differential diagnosis to sexually transmitted disease: genital itch and vaginal discharge as indicators of genital…
2008
OBJECTIVE To examine the association between schistosomiasis and reproductive tract symptoms. METHOD A cross-sectional study was conducted in a Schistosoma haematobium-endemic area of rural Zimbabwe. A total of 483 permanently resident adult women of Mupfure Ward aged 20-49 were interviewed and examined clinically, each providing three consecutive urine samples. Logistic regression analysis was used to control for sexually transmitted diseases (STDs). RESULTS Women with genital sandy patches had significantly more genital itch (P = 0.009) and perceived their discharge as abnormal (P = 0.003). Eighty percent of the women who had genital itch, yellow discharge, and childhood or current waterb…