Search results for "Distance visual acuity"

showing 10 items of 21 documents

Visual performance of the Akreos Adapt AO intraocular lens in patients with different corneal profiles measured with an adaptive optics visual simula…

2012

AIMS: To evaluate the visual performance of an aberration-free intraocular lens (IOL) in patients with different corneal profiles using adaptive optics visual simulation. METHODS: A crx1 adaptive optics visual simulator was used to simulate the aberration pattern of an aberration-free IOL combined with five corneal profiles: virgin corneas and corneas with low and high myopic ablations and low and high hyperopic ablations. Ten eyes of 10 subjects were evaluated, and monocular distance visual acuity (VA) at 100%, 50% and 10% of contrast was measured. RESULTS: At 100% of contrast, no differences were found in VA values among virgin corneas, low and high myopic ablations and low hyperopic abla…

AdultCorneal Wavefront AberrationDistance visual acuityPseudophakiagenetic structuresmedia_common.quotation_subjectmedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityIntraocular lensDiagnostic Techniques OphthalmologicalProsthesis DesignContrast SensitivityYoung AdultCellular and Molecular NeuroscienceLens Implantation IntraocularMyopiaHumansContrast (vision)MedicineIn patientAdaptive opticsSimulationmedia_commonLenses IntraocularPhacoemulsificationbusiness.industryAblationeye diseasesSensory SystemsOphthalmologySpherical aberrationHyperopiaOftalmologíaOptometryLasers Excimersense organsbusinessBritish Journal of Ophthalmology
researchProduct

Effect of Simulated IOL Tilt and Decentration on Spherical Aberration After Hyperopic LASIK for Different Intraocular Lenses

2011

PURPOSE: To evaluate visual quality differences among intraocular lenses (IOLs) in patients with previous hyperopic laser ablations and to assess the impact of decentration and tilt of IOLs on visual quality. METHODS: An adaptive optics visual simulator was used to simulate the wavefront aberration pattern of one aberration-correcting IOL (AcrySof IQ SN60WF, Alcon Laboratories Inc) and two spherical IOLs with different amounts of positive spherical aberration (Akreos Adapt [Bausch & Lomb] and Triplato [AJL Ophthalmic]) in five situations—centered, 0.2 mm and 0.4 mm of decentration, and 2° and 4° of tilt—in two groups: simulated low hyperopic laser corneal ablation (low hyperopia group)…

AdultCorneal Wavefront AberrationDistance visual acuityVisual acuitygenetic structuresmedicine.medical_treatmentmedia_common.quotation_subjectKeratomileusis Laser In SituVisual AcuityArtificial Lens Implant MigrationRefraction OcularYoung AdultPostoperative ComplicationsHumansMedicineContrast (vision)media_commonLenses Intraocularbusiness.industryLASIKeye diseasesOphthalmologySpherical aberrationHyperopiaTilt (optics)Intraocular lensesDecreased Visual AcuityOftalmologíaOptometryLasers ExcimerSurgerysense organsmedicine.symptombusinessJournal of Refractive Surgery
researchProduct

Accommodative Functions with Multifocal Contact Lenses: A Pilot Study

2011

PURPOSE: To evaluate accommodative response and facility in presbyopic patients fitted with several types of simultaneous-image multifocal contact lenses (CLs). METHODS: Six presbyopic patients, unadapted wearers of simultaneous-image bifocals, were fitted with the Focus Progressives and the low- and high-addition Pure Vision simultaneous vision multifocal CLs. Each individual wore each of the three types of lenses in successive random order. Accommodative response, accommodative facility, visual acuity, and contrast sensitivity at distance and near were evaluated in all cases. A control group of eight non-presbyopic patients was also studied. RESULTS: The mean age was 28.6 +/- 2.72 and 51.…

AdultMaleAccommodative responseDistance visual acuityVisual acuityContact Lensesmedia_common.quotation_subjectVisual AcuityPilot ProjectsContrast SensitivityNear visionHumansMedicineContrast (vision)media_commonbusiness.industryAccommodation OcularEquipment DesignPresbyopiaPresbyopiaMiddle AgedPrognosismedicine.diseaseOphthalmologyOptometryFemalemedicine.symptombusinessAccommodationMaximum amplitudeFollow-Up StudiesOptometryOptometry and Vision Science
researchProduct

Five-year functional outcomes and vault of -20 diopter myopic phakic intraocular lens implantation.

2015

Purpose To evaluate refractive and visual outcomes and complications associated with phakic intraocular lens (pIOL) implantation to correct high myopia. Settings Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Design Retrospective observational case series. Methods Uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA), refraction, vault, and adverse effects were evaluated after 5 years with Visian ICMV4 pIOL. Results Mean spherical equivalent (SE) dropped from −18.32 ± 2.37 diopters (D) preoperatively to −0.88 ± 0.52D 5 years postoperatively; 61% of eyes were within ±0.75 D of the target. The mean Snellen decimal CDVA and UDVA were 0.73 ± 0.23 and 0…

AdultMalePhakic Intraocular LensesVisual acuityAnterior subcapsular cataractDistance visual acuityBiometrygenetic structuresmedicine.medical_treatmentVisual AcuityPhakic intraocular lensRefraction OcularPostoperative ComplicationsLens Implantation IntraocularAnterior Eye SegmentmedicineMyopiaHumansDioptreRetrospective StudiesEfficacy indexbusiness.industryHigh myopiaCataract surgeryeye diseasesSensory SystemsOphthalmologyOptometrySurgeryFemalesense organsmedicine.symptombusinessTomography Optical CoherenceFollow-Up StudiesJournal of cataract and refractive surgery
researchProduct

Clinical Impact of a Spontaneous Decentration of a Phakic Refractive Lens

2011

PURPOSE To evaluate the clinical impact and possible causes of a spontaneous decentration of a phakic refractive lens (PRL) implanted in a highly myopic eye, and analyzing the visual, refractive, and aberrometric outcome as well as the possible causes for this phenomenon. METHODS The description of a case of bilateral high myopia corrected by implantation with the phakic intraocular lens (pIOL) PRL (Carl Zeiss Meditec, Germany) is presented and documented. Both eyes had similar anatomical configuration, and therefore, a pIOL (Model 101) with the same size was implanted without any associated intraoperative complication. Clinical outcomes were evaluated during a 3-month follow-up. RESULTS Im…

AdultMalePhakic Intraocular Lensesmedicine.medical_specialtyDistance visual acuitygenetic structuresVisual AcuityComa (optics)Anatomical configurationRefraction OcularPhakic intraocular lensPostoperative ComplicationsOphthalmologyAberrometryMyopiamedicineHumansbusiness.industryLens SubluxationRefractive lensSubjective refractioneye diseasesOphthalmologySpherical aberrationsense organsbusinessFollow-Up StudiesOptometryOptometry and Vision Science
researchProduct

Refractive lens exchange with the Acri. Twin asymmetric diffractive bifocal intraocular lens system

2009

PURPOSE To evaluate efficacy, safety, and predictability after refractive lens exchange (RLE) in patients who had implantation of asymmetric Acri.Twin bifocal diffractive intraocular lenses. METHODS The study comprised 130 eyes of 65 consecutive patients after RLE who had bilateral implantation of the Acri.Twin system. Eyes were divided into myopic and hyperopic groups. Binocular uncorrected distance visual acuity, best-corrected distance visual acuity (BCVA), uncorrected distance near visual acuity, and best distance-corrected near visual acuity (BCNVA) were recorded preoperatively and 6 months after surgery. RESULTS Efficacy indexes were 0.99 for myopic and 0.93 for hyperopic patients at …

AdultMaleReoperationmedicine.medical_specialtyVisual acuityDistance visual acuitygenetic structuresmedicine.medical_treatmentVisual AcuityIntraocular lensRefractive lens exchangeFunctional Laterality03 medical and health sciences0302 clinical medicineLens Implantation IntraocularOphthalmologyMyopiamedicineHumansIn patientProspective StudiesAgedLenses IntraocularPhacoemulsificationbusiness.industryPresbyopiaGeneral MedicinePresbyopiaMiddle AgedMultifocal intraocular lensmedicine.diseaseeye diseasesOphthalmologyHyperopiaIntraocular lenses030221 ophthalmology & optometryFemalesense organsmedicine.symptombusiness030217 neurology & neurosurgeryEuropean Journal of Ophthalmology
researchProduct

Early clinical outcomes after small incision lenticule extraction surgery (SMILE)

2018

Abstract Purpose Dry eye is known to impact on clinical outcomes after laser vision correction and the use of a newer ‘all femtosecond laser’ surgical approach may be associated with less impact on the ocular surface post-operatively. The purpose of this study was to evaluate the early clinical outcomes and tear instability after the first small incision lenticule extraction (SMILE) cases undertaken by three surgeons at a single site in the UK. Methods Retrospective audit. Seventy-one eyes of 37 patients underwent SMILE surgery using the Zeiss VisuMax laser system (Carl Zeiss Meditec, Germany). Uncorrected and corrected distance visual acuity, spherical equivalent refraction, fluorescein en…

AdultMalemedicine.medical_specialtyVisual acuityDistance visual acuitygenetic structuresCorneal Surgery LaserCorneal StromaVisual AcuityRefraction Ocularlaw.invention03 medical and health sciences0302 clinical medicineSingle sitelawOphthalmologyMyopiamedicineHumansSmall incision lenticule extractionSmile surgeryRetrospective StudiesSurgical approachKeratometerbusiness.industryCorneal TopographyGeneral Medicineeye diseasesSurgeryOphthalmologyTears030221 ophthalmology & optometryFemaleLasers Excimersense organsmedicine.symptombusinessOcular surface030217 neurology & neurosurgeryOptometry
researchProduct

Visual performance with simultaneous vision multifocal contact lenses.

2011

Purpose:  The aim was to assess visual performance after PureVision high addition multifocal contact lens (PM) fitting through contrast sensitivity measured under different illumination levels for both distance and near. Methods:  In a cross-over study, 20 presbyopic patients were randomly assigned to PM or spectacles. Near contrast sensitivity was measured with the Vistech VCTS 6500 system. Distance contrast sensitivity and distance visual acuity (VA) were measured with the Functional Vision Analyser under photopic (85 cd/m2) and mesopic (3.0 cd/m2) conditions, the latter also under two levels of induced glare: 1.0 lux and 28 lux. Near VA was measured by logMAR charts under approximately 8…

Adultmedicine.medical_specialtyDistance visual acuitygenetic structuresMesopic visionContact Lensesmedia_common.quotation_subjectVisual AcuityContrast SensitivityOpticsOphthalmologymedicineContrast (vision)Humansmedia_commonMathematicsMonocularCross-Over Studiesbusiness.industryGlare (vision)Accommodation OcularPresbyopiaEquipment DesignPresbyopiaMiddle Agedmedicine.diseaseeye diseasesContact lensOphthalmologyTreatment OutcomebusinessOptometryPhotopic visionFollow-Up StudiesClinicalexperimental optometry
researchProduct

Infracyanine Green vs. Brilliant Blue G in Inverted Flap Surgery for Large Macular Holes: A Long-Term Swept-Source OCT Analysis

2020

Background and Objectives: To compare the long-term toxicity of infracyanine green (IFCG) to brilliant blue G (BBG) in inverted internal limiting membrane flap surgery (I-ILMFS) for large, full-thickness macular holes (FTMHs). Materials and Methods: Prospective randomized study including 39 eyes with &ge

Indocyanine GreenMalemedicine.medical_specialtyDistance visual acuitygenetic structuresswept-source OCTlarge macular holeNerve fiber layerContrast MediaInfracyanine greenRetinaSurgical FlapsArticlechemistry.chemical_compoundRosaniline DyesmedicineHumansExternal limiting membranebrilliant blue GAgedAged 80 and overlcsh:R5-920inverted flap surgerySettore MED/30 - Malattie Apparato Visivobusiness.industryInternal limiting membraneRetinalGeneral MedicineMiddle AgedRetinal Perforationseye diseasesSurgeryGanglionTreatment Outcomemedicine.anatomical_structureInfracyanine greenchemistryFemalebusinesslcsh:Medicine (General)Infracyanine green; brilliant blue G; inverted flap surgery; large macular hole; swept-source OCTTomography Optical CoherenceBrilliant blue GMedicina
researchProduct

Prospective visual evaluation of apodized diffractive intraocular lenses

2006

To evaluate distance, intermediate, and near visual performance in patients who had multifocal apodized diffractive intraocular lens (IOL) implantation.Fernández-Vega Ophthalmological Institute, Oviedo, Spain.The best corrected distance visual acuity, best distance-corrected near visual acuity, intermediate visual acuity, distance contrast sensitivity under photopic and mesopic conditions, and patient satisfaction were measured in 325 patients and 335 patients who had bilateral implantation of the model SA60D3 IOL (AcrySof ReSTOR, Alcon) and model SN60D3 IOL (AcrySof Natural ReSTOR), respectively.At the 6-month postoperative visit, binocular best corrected distance acuity with the ReSTOR IO…

Malemedicine.medical_specialtyDistance visual acuityPseudophakiagenetic structuresMesopic visionmedicine.medical_treatmentmedia_common.quotation_subjectAcrylic ResinsVisual AcuityIntraocular lensProsthesis DesignContrast SensitivityLens Implantation IntraocularSurveys and QuestionnairesOphthalmologymedicineHumansContrast (vision)In patientProspective StudiesAgedmedia_commonLenses IntraocularPhacoemulsificationbusiness.industryPhacoemulsificationMiddle Agedeye diseasesSensory SystemsOphthalmologyIntraocular lensesPatient SatisfactionQuality of LifeOptometryFemaleSurgerybusinessPhotopic visionJournal of Cataract and Refractive Surgery
researchProduct