Mathematical formulation of pulse amplitude modulation selective harmonic elimination in multilevel three phase inverters
2022
In this paper multilevel cascaded H-bridges (CHB) three phase inverters with 2n dc sources, n=1,2,3,... are considered and a mathematical formulation providing both 2n switching angles and dc voltage source to eliminate n+1 harmonics and their respective multiple from their output voltage waveform, is proposed. The computed angles don't depend on modulation index and the source voltages linearly vary with it. The proposed procedure finds the solution through an analytical formula that avoids to solve transcendental systems and presents very low computational cost. A lot of low order harmonics are eliminated, returning a very low total harmonic distortion (THD). Particularly for 9-level conf…
A self-synchronizing instrument for harmonic sources detection in power systems
2004
The deregulation of energy markets holds out new prospects for contract between customers and utilities, in which the price of energy can depend on voltage quality and load characteristics, as well as on the responsibility for disturbances caused to supply voltage in power systems. In this context, harmonic sources detection is one of the main problems, because of equipment sensibility and the proliferation of loads which absorb non-sinusoidal currents. In this paper the authors present a new instrument based on a time domain method for the detection of harmonic active powers in three-phase systems, which can be usefully applied even in the presence of unbalance or asymmetry. The amplitude …
Control of ultra-high switching frequency power converters using virtual flux-based direct power control
2017
This paper presents a control technique for ultra-high switching frequency rectifiers known as virtual flux-based direct power control (VF-DPC). This method utilizes AC voltage sensors to provide better power quality at the input and output of power converters. Performance of an ultra-high switching frequency converter using the extended and conventional VF-DPC method is analyzed. The analysis has shown that the extended VF-DPC method can reduce better the total harmonic distortion (THD) of input currents and the ripples of the output DC voltage as compared to conventional VF-DPC. Finally, the effect of switching frequency and inductance size on rectifier operation is investigated in this s…
Metrological characterization and operating principle identification of static meters for reactive energy: an experimental approach under nonsinusoid…
2009
In this paper, an experimental approach is proposed for the metrological characterization of the static meters for reactive energy and for the individuation of their operating principle in nonsinusoidal conditions. The proposed approach was developed by starting from the only available accuracy test condition in the presence of the harmonics introduced by the standards for active static meters. In this paper, the proposed approach is described, and some experimental tests are presented, which were performed on some meters of different accuracy classes and with both known and unknown operating principles.
Polluting loads detection in power systems: a decision-making strategy based on nonactive power measurements
2010
In this paper a novel decision-making strategy is proposed for the detection of polluting loads in three-phase power systems. It makes use of simple indices, which are expressed as a function of some nonactive power quantities, previously proposed by the authors and derived from the approach of the IEEE Std. 1459–2000. The decision-making rules for the proposed strategy are presented and discussed, by means of some simulation tests.
The Measurement of Reactive Energy in Polluted Distribution Power Systems: An Analysis of the Performance of Commercial Static Meters
2008
This paper presents a comparative analysis of the performances of both a traditional induction meter and various types of commercial static meters for reactive energy in the presence of harmonic distortion. This is a topical issue, since there are several types of static meters on the market, based on different principles of construction. In accordance with current standards, these meters are designed to operate in sinusoidal conditions and their performance is not tested in the presence of harmonic distortion. However, with the increase of pollution levels in power systems, the meters may be used even in the presence of distorted voltages and/or currents; in such cases, their accuracy may …
A novel approach based on nonactive powers for the identification of disturbing loads in power systems
2007
In this paper, a new approach is proposed for the detection of harmonic sources in polluted power systems. It is a single- point strategy, based on a comparison among different "nonactive" power quantities proposed in literature that, in the same working conditions, assume different values at the same metering section. Some simulations tests were carried out on a standard IEEE test system proposed by other authors as a benchmark system for the analysis of multipoint measurement techniques for harmonic pollution monitoring. The obtained results show that the proposed single-point approach is in agreement with other strategies already proposed in the literature and can provide useful indicati…
A time domain strategy for the measurement of IEEE Standard 1459-2000 power quantities in nonsinusoidal three-phase and single-phase systems
2008
This paper describes a time domain technique for the detection of fundamental and harmonic components of voltages and currents, which is able to evaluate all the quantities required by IEEE standard 1459-2000. The technique does not require any spectral analysis to separate the fundamental positive-sequence components from harmonic, negative-sequence and zero-sequence ones. In the paper the development of the proposed technique is presented for three-phase systems, both three-wires and four-wires, as well as for single-phase systems. The implementation of the proposed technique on a PC-based instrument is also described and experimental results are presented. Finally, accuracy specification…
Theoretical and Experimental Comparison of Total Harmonic Distortion Factors for the Evaluation of Harmonic and Interharmonic Pollution of Grid-Conne…
2006
Grid connected photovoltaic systems are increasingly used in electrical distribution systems. However, they inject distorted currents. Therefore special attention must be paid to harmonic and interharmonic measurements. The new edition of IEC 61000-4-7 introduces the concept of harmonic and interharmonic groups, which implies new expressions for Total Harmonic Distortion factors. In the paper a theoretical and experimental comparison is made between the different total harmonic distortion factors in order to show which of the currently defined distortion factors is best-suited to detect harmonic and interharmonic pollution. Experimental tests were carried out first by means of a calibrator …
A Time-Domain Approach Based on the IEEE Std 1459-2000 for the detection of Loads Producing Harmonic Distortion
2008
This paper presents a novel strategy for the detection of harmonic sources in power systems for both the single-phase and the three-phase systems. It is based on the IEEE Std. 1459-2000 approach and it is based only on the separation of the fundamental components from the harmonic content of voltage and current. The proposed strategy do not require any spectral analysis of voltages and currents and it can be entirely implemented in the time domain. In the paper, the formulation of the novel approach is given and some simulation results are presented.