Search results for "Distributed generation"
showing 10 items of 129 documents
Comparison of power quality impact of different photovoltaic inverters- the viewpoint of the grid
2005
This paper presents the results of an experimental analysis performed with the aim of evaluating the effect of many photovoltaic plants on power quality of the grid. Several parameters as voltage and current distortion, flicker, voltage variations at fundamental frequency and power factor have been observed. The measured values have been compared with the limits reported in the standards and, when possibiIe, their dependence on the characteristics of the grid in terms of its impedance has been pointed out.
Controlled Fault-Tolerant Power Converters for Power Quality Enhancement
2013
Power quality depends generally on the interaction of electrical power with electrical equipments. If electrical equipments operate correctly and reliably without being damaged or stressed, a suitable level of power quality is assured. On the other hand, if the electrical equipment malfunctions, is unreliable, or is damaged during normal usage, power quality is poor and probably the economical loss could be important like the technical one. In the scenario of the Distributed Generation, power quality issues will be moreover important because an higher dissemination of power conditioning equipment will be requested and this obviously increases the sources of vulnerability of the electrical s…
Feasibility analysis of a renewable hybrid energy system with producer gas generator fulfilling remote household electricity demand in Southern Norway
2016
Abstract Hybrid energy system is increasingly emerging as an option to produce energy for the remote areas. This paper presented an economic feasibility analysis of a single standalone house operating with a hybrid power plant consisting of a fixed capacity producer gas generator (2 kWe) and other renewable energy sources (Photovoltaic and wind). The National Renewable Energy Laboratory's Hybrid Optimization Model for Electric Renewable (HOMER) was employed which evaluated techno-economic analysis based on the criteria of net present cost and levelized cost of electricity. Taking the site specific daily average solar radiation, average wind speed and load data into account, renewable hybrid…
Techno-economic sizing of off-grid hybrid renewable energy system for rural electrification in Sri Lanka
2015
Abstract Off-grid hybrid renewable-energy-based power systems for rural electrification have become an attractive solution for areas where grid electricity is not feasible. Hybrid energy systems use several energy technologies, and the selection of proper technologies with optimum sizing of the selected components has become very important. The objective of this study has been to investigate the optimum configuration of a hybrid system that can supply electricity to a rural community in Sri Lanka. A rural village in Siyambalanduwa (Sri Lanka) comprising approximately 150 households with a resultant daily electricity demand of 270 kWh and a nighttime peak of 25 kW has been studied. This regi…
Computer Aided Optimization Via Simulation Tools of Energy Generation Systems With Universal Small Wind Turbines
2012
This paper considers the general issues in the project and the optimization of energy generation systems using small universal wind turbines, suitable in Distributed Generation (DG) and computer aided optimization for a better exploitation of wind source. Optimization in this field reveal to be more and more important because the local generation and consumption of electrical power, even for grid connected generators can suffers for unevenness of wind source exploitation, also in terms of wrong directions and in not regular wind flows. Computer aided design and optimization of small plants may give significant improvements in the development of the wind source also in accordance with the pr…
Smart grid integrated green data centres as ancillary service providers
2015
In this paper a review of Green Data Centres facilities to support smart grids operation is proposed. The paper describes the ancillary services a Green Data Centre can provide both in terms of spinning reserve provision and different regulation services. In the application section, a real electrical grid hosting a data centre is considered. The infrastructure is owned by Engineering S.p.A. and is installed in northern Italy. The system has been considered as connected to the MV distribution grid in presence of other renewable energy sources. The impact of possible power management operations over the considered data centre has been studied by means of a simulation software and the spinning…
Optimal Energy Management of Smart Grids With Plug-In Hybrid Electric Vehicles
2015
In this paper, smart grids based on Renewable Energy Sources are addressed. An Italian case study which has been developed in the frame of the research project i-NEXT (Innovation for green Energy and eXchange in Transportation) is presented. Storage elements are included. Electric and fuel cell powered vehicles' charging stations are here included as local loads. In this paper, power management algorithms and the control logic are described. The control subsystem aims at an efficient management of the involved renewable energy sources avoiding faults in the power system and ensuring a fully functional supply of local loads. A “Service Center” software collecting data from renewable sources,…
Charging management of grid integrated battery for overcoming the intermittency of RE sources
2016
Grid integration of distributed generation (DG) systems with energy storage system can help not only in increasing the more penetration of DG systems into the network but it is also going to help in improving the power system dynamics, stability and control as well as helping in demand side management. In this work, a method for integrating an energy storage with the grid which can provide the prescribed active and reactive power to the grid is presented. The main objective is to ensure a high state of charge (SOC) of the battery with the innovative control system for taking part in power system control. Active and reactive power dispatching using a bi-directional DC-DC converters and a vol…
Reassessment of voltage stability for distribution networks in presence of DG
2016
There is a growing interest in integrating renewable energy based distributed generation (DG) in the electrical power distribution networks. The installation of DG units at distribution level impacts critically the planning and operation characteristics of the network. The type, location, number and capacity of the integrated DGs affects system behavior and performance. In this paper the effect of installing new DGs on the distribution network voltage stability is studied. The optimal location of the newly installed DGs are decided based on the Power Stability Index (PSI) and Voltage Stability Index (VSI). Moreover, Voltage Stability Margin (VSM) of the interconnected DG distribution networ…
An Investigation of Protection Devices Coordination Effects on Distributed Generators Capacity in Radial Distribution Systems
2013
In the recent years, with the concept of Smart Grid, there are a great interest in integration of renewable energy based distributed generation (DG) units at distribution level. Along with a number of benefits, penetration of DG units in the distribution system imposes some serious challenges; protection requirements turns up as one of the most critical challenge in DG integration. In this paper the possibility and the potentiality of occurring mis-coordination between protection devices in radial distribution network is studied. The impacts of protection devices coordination on DG capacity are investigated. The penetration level, number, and location of interconnected DGs are used as param…