Search results for "Distribution networks"
showing 10 items of 62 documents
A Multi-Port Approach to Solve Distribution Networks with Meshes and PV Nodes
2007
A new methodology based on the backward/forward (b/f) technique for the load flow solution in distribution systems is here proposed. The methodology takes efficiently into account the fixed voltage nodes and uses a reduced bus impedance matrix. In this way, it is possible to attain, for the unknowns at the PV nodes, the same values that are attainable solving the network with the methods adopted for transmission systems. With the same methodology it is possible to take into account also the meshes. If the network contains only meshes, the relevant model is linear and it is the one including the compensation currents. The presence of PV nodes introduces non linearity in the model and an iter…
Hydropower Potential in Water Distribution Networks: Pressure Control by PATs
2014
Pressure control is one of the main techniques to control leakages in Water Distribution Networks (WDNs) and to prevent pipe damage, improving the delivery standards of a water supply systems. Pressure reducing stations (PRSs) equipped by either pressure reducing valves or motor driven regulating valves are commonly used to dissipate excess hydraulic head in WDNs. An integrated new technical solution with economic and system flexibility benefits is presented which replaces PRSs with pumps used as turbines (PATs). Optimal PAT performance is obtained by a Variable Operating Strategy (VOS), recently developed for the design of small hydropower plants on the basis of valve time operation, and n…
Contaminant Intrusion through Leaks in Water Distribution System: Experimental Analysis
2015
Abstract This paper presents the results of experimental tests on the intrusion of contaminant through pipe cracks in water distribution network resulting from low/negative pressures. The tests were carried out on a looped distribution network at the University of Enna and were performed first producing a pressure transient that causes negative pressures then reproducing intermittent supply. A soluble contaminant was added to the water volume in the network through a pipe crack. Sampling of water volume was carried out in two nodes of the network and the contaminant concentrations were measured. It was showed that: the contaminant was drawn in and transported, in the first set of tests; the…
SELECTION OF REHABILITATION ALTERNATIVES OF WATER DISTRIBUTION SYSTEMS IN CONDITION OF LACK OF DATA BY CONCISE PERFORMANCE INDICES AND OPTIMIZATION T…
2011
Selection of rehabilitation alternatives in condition of data scarcity by concise performance indices
2011
PUMP AS TURBINE (PAT) IN INTERMITTENT DISTRIBUTION NETWORKS
2012
A hydraulic model was performed in order to evaluate potential energy recovery resulting by the use of centrifugal pump as turbines (PAT) in the water distribution network characterized by the presence of private tanks. The model integrates the Enhanced Global Gradient Algorithm (EGGA) (Todini [1], Giustolisi et al. [2]), with a pressure driven model (Criminisi et al. [3]) that entails a more realistic representation of the influence of the private tanks filling and emptying process in the network behaviour. The model was applied to real case study: a district metered area in Palermo (Italy). Namely three different scenarios were analyzed and compared with the actual scenario (Scenario 0 - …
Critical issues and future prospects of the secondary substation in smart grid context
2014
This paper is focused on the new role of the secondary substation in the smart grids context. This innovative view has been proposed and developed in the framework of two Research Projects: NewCabELARC Project and Reipersei Project. The latter provides a concrete and comprehensive low cost solutions for the smart grid monitoring and control, allowing the real diffusion and integration of Distributed Generation and the full exploitation of Renewable Energy Sources. In this field, this paper shows how the secondary substation (SS) takes the role of smart transducer node where innovative devices can be located, collecting the measurement data coming from the field devices (power and energy met…
Water distribution network robust design based on energy surplus index maximization
2015
The aim of this paper is to show that energy surplus indices, such as resilience index, besides providing a very good indirect measure of water distribution network reliability to be adopted during the design phase, represent also a valuable and effective indicator of the robustness of the network in alternative network scenarios, and can thus be profitably used in condition of future demands uncertainty. The methodology adopted consisted of (I) multi-objective design optimization performed in order to minimize construction costs while maximizing the resilience index; (II) retrospective performance assessment of the alternative solutions of the Pareto front obtained, under demand conditions…
Raman Investigations to Identify Corallium rubrum in Iron Age Jewelry and Ornaments
2016
International audience; During the Central European Iron Age, more specifically between 600 and 100 BC, red precious corals (Corallium rubrum) became very popular in many regions, often associated with the so-called (early) Celts. Red corals are ideally suited to investigate several key questions of Iron Age research, like trade patterns or social and economic structures. While it is fairly easy to distinguish modern C. rubrum from bone, ivory or shells, archaeologists are confronted with ancient, hence altered, artifacts. Due to ageing processes, archaeological corals lose their intensive red color and shiny surface and can easily be confused with these other light colored materials. We pr…
Definition of Water Meter Substitution Plans based on a Composite Indicator
2014
This paper presents a water meter substitution plan based on a composite "Replacement indicator" which was defined and compared with common substitution strategies based on meter age and on run-to-fail approaches. The methodology was applied to one of the 17 sub-networks in which the Palermo city water distribution network (Italy) is divided. The analysis was carried out considering a substitution budget limitation and the results showed that the use of "Replacement indicator" outperform the classical substitution strategies based on meter age because it takes into account some other variables that may affect meter precision and wearing. (C) 2013 The Authors. Published by Elsevier Ltd.