Search results for "Diviner"

showing 3 items of 3 documents

Indirect estimation of calibration equation parameters for Sentek Diviner 2000 capacitance probe by means of soil physical properties

2014

Measurements of soil water content (SWC) are often used for irrigation scheduling. Accurate monitoring of SWC is necessary, for example, to identify the exact irrigation timing and the amount of water volume to supply according to the crop requirement. The use of capacitance probes, measuring the apparent soil dielectric permittivity, indirectly related to soil water status, have been increasing during the last decade, as proved by the numerous researches carried out to determine, for different soil types, site-specific calibration relationships between SWC and the scaled frequency (SF) measured by the sensor. However, for swelling/shrinking clay soils, there is a lack of knowledge on how t…

Settore AGR/03 - Arboricoltura Generale E Coltivazioni ArboreeFDR soil moisture sensors Diviner 2000 CalibrazioneSettore AGR/08 - Idraulica Agraria E Sistemazioni Idraulico-Forestali
researchProduct

Closure to “Laboratory and Field Calibration of the Diviner 2000 Probe in Two Types of Soil” by J. Haberland, R. Gálvez, C. Kremer, and C. Carter

2015

The authors deal with the quite interesting and actual problem of Diviner 2000 capacitance probe calibration and present some field and laboratory data obtained on two different layers (0–0.26 and 0.26–0.50 cm) of the same soil profile, characterized by different textural class. The importance of site-specific calibration of sensors used to monitor soil or plant water status assumes a particular relevance in semiarid environments where the application of precision irrigation represents an appropriate management strategy aimed to achieve high values of water use efficiency (Cammalleri et al. 2013). Moreover, in clay soils, physical properties are strongly influenced by soil water content (Pr…

Soil scienceSoil typeAgricultural and Biological Sciences (miscellaneous)Soil waterSoil horizonEnvironmental scienceField calibrationGeotechnical engineeringCapacitance probeWater-use efficiencyAir gap (plumbing)Water Science and TechnologyCivil and Structural EngineeringDivinerJournal of Irrigation and Drainage Engineering
researchProduct

Discussion of “Laboratory and field calibration of the Diviner 2000 probe in two types of soil” by J. Haberland, PhD, R. Galvez, C. Kremer, PhD, and …

2014

The authors deal with the quite interesting and actual problem of Diviner 2000 capacitance probe calibration and present some field and laboratory data obtained on two different layers (0-0.26 cm and 0.26-0.50 cm) of the same soil profile, characterized by different textural class. The importance of site-specific calibration of sensors used to monitor soil or plant water status assumes a particular relevance in semi-arid environments where the application of precision irrigation represents an appropriate management strategy aimed to achieve high values of water use efficiency (Cammalleri et al., 2013). Moreover in clay soils, physical properties are strongly influenced by soil water content…

FDR Soil moisture sensor Laboratory and field calibration Diviner 2000 probeSettore AGR/08 - Idraulica Agraria E Sistemazioni Idraulico-Forestali
researchProduct