Search results for "Dose rate"

showing 10 items of 65 documents

SU-E-T-516: Limitations and Clinical Implications of the TG-43 Formalism for High-Dose-Rate Skin Brachytherapy

2013

Purpose: In high‐dose‐rate (HDR) skin brachytherapy, sources are located outside, in contact with, or implanted at some depth below the skin surface. Nowadays, most TPS use the TG‐43 formalism that is based on sources within an infinite water medium, without accounting for the scatter defect due to surrounding air. The purpose of the present study is to evaluate the limitations of the TG‐43 formalism in HDR skin brachytherapy. Methods: This study examined two HDR sources (Ir‐192 and Co‐60) together with a hypothetical Yb‐169 source. Dose distributions were obtained using Monte Carlo methods (i.e., GEANT4). The following configurations were investigated: 1)A typical clinical case consisting …

Materials sciencebusiness.industrymedicine.medical_treatmentMonte Carlo methodBrachytherapyGeneral MedicineDose distributionFormalism (philosophy of mathematics)Skin surfacemedicineDosimetryClinical caseNuclear medicinebusinessDose rateMedical Physics
researchProduct

Design and characterization of a new high-dose-rate brachytherapy Valencia applicator for larger skin lesions

2016

Purpose: The aims of this study were (i) to design a new high-dose-rate (HDR) brachytherapy applicator for treating surface lesions with planning target volumes larger than 3 cm in diameter and up to 5 cm in size, using the microSelectron-HDR or Flexitron afterloader (Elekta Brachytherapy) with a 192Ir source; (ii) to calculate by means of the Monte Carlo(MC) method the dose distribution for the new applicator when it is placed against a water phantom; and (iii) to validate experimentally the dose distributions in water. Methods: The penelope2008MC code was used to optimize dwell positions and dwell times. Next, the dose distribution in a water phantom and the leakage dose distribution arou…

Materials sciencebusiness.industrymedicine.medical_treatmentMonte Carlo methodBrachytherapyGeneral MedicineImaging phantomHigh-Dose Rate Brachytherapy030218 nuclear medicine & medical imagingPercentage depth dose curve03 medical and health sciencesKerma0302 clinical medicine030220 oncology & carcinogenesisIonization chambermedicineDosimetryNuclear medicinebusinessMedical Physics
researchProduct

Aggregation of Frenkel defects under irradiation: a mesoscopic approach

1994

The radiation-induced aggregation of Frenkel defects in solids is studied in terms of a mesoscopic approach. The asymmetry in elastic interactions between mobile interstitials (I-I) and between interstitials and vacancies (I-V) plays a decisive riile in the aggregation of similar defects. The conditions for defect aggregation are studied in detail for NaCl crystals. The critical dose rate for aggregation has been calculated as a function of the temperature as well as the aggregation rate as a function of temperature and dose rate. Furthermore, the r&e of deep traps (like impurities and di-vacancies), reducing the mobility of interstitials, and the r&le of dislocations serving as sinks for i…

Nuclear and High Energy PhysicsMesoscopic physicsMaterials sciencemedia_common.quotation_subjectAggregation rateAsymmetryCrystallographyImpurityChemical physicsCritical doseIrradiationDose rateInstrumentationmedia_commonNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
researchProduct

Influence of Photon Energy Spectra from 192Ir and 125I Brachytherapy Sources on Kerma and Dose Rates in Water and Air

2010

Nuclear physicsKermaOncologybusiness.industrymedicine.medical_treatmentBrachytherapyMedicineRadiology Nuclear Medicine and imagingPhoton energybusinessNuclear medicineDose rateSpectral lineBrachytherapy
researchProduct

A Generic High-Dose-Rate 192Ir Source Model for Model-Based Dose Calculation Methods in Brachytherapy Beyond the TG-43 Formalism

2013

OncologyDose calculationbusiness.industryFormalism (philosophy)medicine.medical_treatmentQuantum electrodynamicsBrachytherapymedicineRadiology Nuclear Medicine and imagingDose ratebusinessSource modelBrachytherapy
researchProduct

A Phase II Trial of Fixed-Dose Rate Gemcitabine plus Capecitabine in Metastatic/Advanced Biliary Tract Cancer Patients

2011

<i>Background:</i> This phase II trial was conducted to determine the activity and safety of the combination of fixed-dose rate (FDR) gemcitabine and capecitabine in metastatic biliary tract cancer (BTC) patients. <i>Methods:</i> Patients with unresectable BTC who had pathologically confirmed adenocarcinoma, no prior chemotherapy, Eastern Cooperative Oncology Group (ECOG) performance status ≤1 and measurable disease were enrolled. Treatment consisted of FDR gemcitabine at 800 mg/m<sup>2</sup> on days 1 and 8 every 21 days with capecitabine administered orally b.i.d. in equal doses (650 mg/m<sup>2</sup> b.i.d.) for 14 days (28 doses). <i>…

OncologyMaleCancer Researchmedicine.medical_specialtyDisease free survivalSettore MED/06 - Oncologia MedicaDeoxycytidineDisease-Free SurvivalCapecitabineBiliary tract cancer; Capecitabine; Fixed-dose rate; GemcitabineInternal medicineAntineoplastic Combined Chemotherapy ProtocolsmedicineHumansNeoplasm MetastasisCapecitabineAgedNeoplasm StagingBiliary tract cancerFixed-dose ratebusiness.industryGeneral MedicineFixed dose rateMiddle AgedGemcitabineGemcitabineClinical trialBiliary Tract NeoplasmsOncologyBiliary tract cancerNeoplasm stagingFemaleFluorouracilbusinessmedicine.drug
researchProduct

Dosimetric characteristics of a new unit for electronic skin brachytherapy

2013

PURPOSE: Brachytherapy with radioactive high dose rate (HDR) (192)Ir source is applied to small skin cancer lesions, using surface applicators, i.e. Leipzig or Valencia type. New developments in the field of radiotherapy for skin cancer include electronic brachytherapy. This technique involves the placement of an HDR X-ray source close to the skin, therefore combining the benefits of brachytherapy with the reduced shielding requirements and targeted energy of low energy X-rays. Recently, the Esteya(®) Electronic Brachytherapy System (Esteya EBS, Elekta AB-Nucletron, Stockholm, Sweden) has been developed specifically for HDR brachytherapy treatment of surface lesions. The system provides rad…

Original Paperelectronic brachytherapybusiness.industrymedicine.medical_treatmentTreatment durationSuperficial radiotherapyBrachytherapyElectronic skinsuperficial radiotherapyRadiation therapyLow energyOncologynonmelanoma skin-cancermedicineskin brachytherapyRadiology Nuclear Medicine and imagingNuclear medicinebusinessDose rateDepth doseJournal of Contemporary Brachytherapy
researchProduct

Trends in infant leukaemia in West Germany in relation to in utero exposure due to Chernobyl accident.

1998

A temporary increase in the incidence of infant leukaemia in Greece was reported by Petridou et al., which was attributed to in utero exposure to ionising radiation resulting from the Chernobyl accident. We performed a similar analysis based on the data of the German Childhood Cancer Registry in order to check whether the observation could be confirmed by means of independent data. Applying the same definitions as Petridou et al., we also observed an increased incidence of infant leukaemia in a cohort of children born after the Chernobyl accident. More detailed analyses, regarding areas with different contamination levels and dose rate gradients over time after the accident, showed, however…

Pediatricsmedicine.medical_specialtyBiophysicsRadiation DosageInfant Newborn DiseasesWest germanyNuclear ReactorsPregnancyEnvironmental healthGermanyRadiation IonizingMedicineHumansIndependent dataRadiation InjuriesGeneral Environmental ScienceLeukemia Radiation-InducedChildhood Cancer RegistryRadiationbusiness.industryIncidence (epidemiology)Infant NewbornInfantIn uteroMaternal ExposureChild PreschoolCohortFemalebusinessDose rateRadioactive Hazard ReleaseUkrainePower PlantsRadiation and environmental biophysics
researchProduct

The FiR 1 photon beam model adjustment according to in-air spectrum measurements with the Mg(Ar) ionization chamber.

2014

Abstract The mixed neutron–photon beam of FiR 1 reactor is used for boron–neutron capture therapy (BNCT) in Finland. A beam model has been defined for patient treatment planning and dosimetric calculations. The neutron beam model has been validated with an activation foil measurements. The photon beam model has not been thoroughly validated against measurements, due to the fact that the beam photon dose rate is low, at most only 2% of the total weighted patient dose at FiR 1. However, improvement of the photon dose detection accuracy is worthwhile, since the beam photon dose is of concern in the beam dosimetry. In this study, we have performed ionization chamber measurements with multiple b…

PhotonQuantitative Biology::Tissues and OrgansPhysics::Medical PhysicsMonte Carlo methodAnalytical chemistryBoron Neutron Capture TherapySensitivity and SpecificityOpticsNuclear ReactorsDosimetryPenelopeIonization ChamberDosimetryComputer SimulationPhoton beamRadiometryMonte CarloPhysicsPhotonsRadiationModels Statisticalbusiness.industryAirRadiotherapy Planning Computer-AssistedReproducibility of ResultsEquipment DesignNeutron radiationEquipment Failure AnalysisIonization chamberBNCTPhysics::Accelerator PhysicsComputer-Aided DesignDose ratebusinessMCNP5Beam (structure)Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine
researchProduct

Erratum: “Fitted dosimetric parameters of high dose-rate 192Ir sources according to the AAPM TG43 formalism” [Med. Phys. 28 (4), 654-660 (2001)]

2001

PhysicsFormalism (philosophy of mathematics)Quantum electrodynamicsDosimetryGeneral MedicineStatistical physicsDose rateMedical Physics
researchProduct