Search results for "Dosimeter"
showing 10 items of 96 documents
209 New Fricke gel with high sensitivity and low diffusion for 3D-MRI dosimetry
2018
Purpose Fricke gel (FG) dosimeters are good candidates for 3D dose assessment in biological materials. Their effective atomic number and density are similar to those of soft tissue. In view of their chemical and morphological characteristics, FG serve as dosimeters and as phantoms at the same time. FG dosimeters are obtained by incorporating an acidic aqueous solution of ferrous ions Fe2+ into a gel matrix. In order to address the limitations of gels based on natural matrices, we have studied FG produced with a matrix of poly-vinyl alcohol (PVA) cross-linked with glutaraldehyde (GTA). Materials and methods The proposed gel contains 10% w/v of PVA and GTA of 1%w/v. A common formulation agaro…
Erratum: “TG-43 U1 based dosimetric characterization of model 67-6520 Cs-137 brachytherapy source”
2012
Purpose: Brachytherapy treatment has been a cornerstone for management of various cancer sites, particularly for the treatment of gynecological malignancies. In low dose rate brachytherapy treatments,C137s sources have been used for several decades. A new C137s source design has been introduced (model 67-6520, source B3-561) by Isotope Products Laboratories (IPL) for clinical application. The goal of the present work is to implement the TG-43 U1 protocol in the characterization of the aforementioned C137s source. Methods: The dosimetriccharacteristics of the IPLC137s source are measured using LiF thermoluminescent dosimeters in a Solid Water™ phantom material and calculated using Monte Carl…
Determination of New Radical Species in Ammonium Tartrate Dosimeters by CW- and Pulsed-EPR Techniques
2015
Samples of ammonium tartrate irradiated with doses of about 0.1–1 kGy by different beams of ionizing radiation (60Co–γ, 19 MeV protons and 62 MeV per nucleon carbon ions) were studied by continuous-wave electron paramagnetic resonance (cw-EPR) and by pulse-EPR techniques. Careful analysis of the cw-EPR and of the echo-detected EPR spectra allowed the identification of a second radical in the system besides the already known radical formed at high temperature by an hydrogen elimination at C(2) position [M. Brustolon et al., Res. Chem. Int 4:359, 1996]. The spectrum of the radical is compatible with that of a radical obtained by hydroxyl elimination.
A New Dosimeter Methacholine Challenge Protocol Based On A Single Methacholine Concentration
2010
Technique for routine output verification of Leipzig applicators with a well chamber
2005
The H-type Leipzig applicators are accessories of the microSelectron-HDR system (Nucletron, Veenendaal, The Netherlands) for treatment of superficial malignancies. Recently, the dose rate distributions in liquid water for the whole set of applicators using both source models available for the microSelectron-HDR afterloaders have been obtained by means of the experimentally validated Monte Carlo (MC) code GEANT4. Also an output table (cGy/hU) at 3 mm depth on the applicator central axis was provided. The output verification of these applicators by the user, prior to their clinical use, present practical problems: small detectors such as thermoluminescent dosimeters or parallel-plate ionizati…
Phenol compounds for Electron Spin Resonance dosimetry in gamma and neutron field
2016
The use of neutrons for cancer treatments has stimulated the research for beam characterization in order to optimize the therapy procedures in Neutron Capture Therapy (Altieri, 2008). Several research laboratories have shown an increasing interest aimed at extending the applicability of Electron Spin Resonance (ESR) dosimetry to radiotherapy with different types of radiation beams. In particular, ESR spectrometry provides absorbed dose measurements through the detection of the stable free radicals produced by ionizing radiations. The ESR dosimetric method has many advantages such as simple and rapid dose evaluation, the readout procedure is non-destructive, linear response of many organic a…
Monte Carlo simulation of energy absorbed in phenolic ESR dosimeters added with gadolinium exposed to thermal, epithermal and fast neutrons
2017
Abstract In this work analyses of the energy released per unit mass in phenolic compound exposed to neutron beams were performed with the aim of predicting the increase in dose achievable by addition of gadolinium (Gd) inside the pellets. In particular, Monte Carlo (MC) simulations were carried out for IRGANOX® 1076 phenolic compound irradiated with neutron beams with different energy spectra at various depths inside a water phantom. The addition of gadolinium increases sensitivity of phenolic ESR (electron spin resonance) dosimeters to neutrons thanks to the high gadolinium cross section for neutron capture and to the large number of secondary particles (mainly Auger and internal conversio…
PVA-GTA Fricke gel dosimeters exposed to clinical photons beams: Nuclear Magnetic Resonance Relaxometry and Imaging
2016
Fricke Gel (FXGs) dosimetric system is based on the radiation induced oxidation of ferrous to ferric ions. The application of Fricke gels for ionizing radiation dosimetry is continuously increasing worldwide due to their many favorable properties. However, one of their shortcomings is that ferrous and ferric ions diffuse in the gel matrix. To maintain the spatial integrity of the dose distribution, Fricke gels must be undergoing measurement within a few hours of their irradiation, so that ferric ions remain close to their point of production. Thus, the spatial integrity of the dose distribution in the Fricke gel is maintained (Schreiner, 2015). The gel matrix also contributes to the oxidati…
THE EFFECT OF GADOLINIUM ON THE ESR RESPONSE OF ALANINE AND AMMONIUM TARTRATE EXPOSED TO THERMAL NEUTRONS
2008
Many efforts have been made to develop neutron capture therapy (NCT) for cancer treatment. Among the challenges in using NCT is the characterization of the features of the mixed radiation field and of its components. In this study, we examined the enhancement of the ESR response of pellets of alanine and ammonium tartrate with gadolinium oxide exposed to a thermal neutron beam. In particular, the ESR response of these dosimeters as a function of the gadolinium content inside the dosimeter was analyzed. We found that the addition of gadolinium improves the sensitivity of both alanine and ammonium tartrate. However, the use of gadolinium involves a reduces in or abolishes tissue equivalence b…
In situ formation of pyronin dyes for fluorescence protease sensing
2017
International audience; We report a reaction-based strategy for the fluorogenic detection of protease activity. Based on the "covalent-assembly" probe design principle recently put forward by the Yang group for detection of Sarin related threats (J. Am. Chem. Soc., 2014, 136, 6594-6597), we have designed two unusual nonfluorescent caged precursors (mixed bis-aryl ethers) which are readily converted into a fluorescent unsymmetrical pyronin dye through a domino cyclisation-aromatisation reaction triggered by penicillin G acylase (PGA) or leucine aminopeptidase (LAP). Fluorescence-based in vitro assays and HPLCfluorescence/- MS analyses support the claimed activation mechanism whose the furthe…