Search results for "Dosimeter"

showing 10 items of 96 documents

Obesity Triples the Radiation Dose of Stone Protocol Computerized Tomography

2013

Patients with recurrent nephrolithiasis are often evaluated and followed with computerized tomography. Obesity is a risk factor for nephrolithiasis. We evaluated the radiation dose of computerized tomography in obese and nonobese adults.We scanned a validated, anthropomorphic male phantom according to our institutional renal stone evaluation protocol. The obese model consisted of the phantom wrapped in 2 Custom Fat Layers (CIRS, Norfolk, Virginia), which have been verified to have the same radiographic tissue density as fat. High sensitivity metal oxide semiconductor field effect transistor dosimeters were placed at 20 organ locations in the phantoms to measure organ specific radiation dose…

MaleUrologyRadiographyNephrolithiasisRadiation DosageEffective dose (radiation)Imaging phantomBody Mass IndexRadiation MonitoringRecurrenceReference ValuesHumansMedicineObesityDosimeterPhantoms Imagingbusiness.industryEquivalent doseRadiation doseModels Theoreticalequipment and suppliesBody BurdenTomographyTomography X-Ray ComputedbusinessNuclear medicineBody mass indexJournal of Urology
researchProduct

Influence of a Commercial Lead Apron on Patient Skin Dose Delivered During Oral and Maxillofacial Examinations under Cone Beam Computed Tomography (C…

2017

The purpose of this paper is to investigate the impact of a commercial lead apron on patient skin dose delivered during maxillofacial CBCT in five critical regions by means of solid-state-dosimetry. Five anatomical regions (thyroid gland, left and right breast, gonads, back of the phantom torso) in an adult female anthropomorphic phantom were selected for dose measurement by means of the highly sensitive solid-state dosimeter QUART didoSVM. Ten repeated single exposures were assessed for each patient body region for a total of five commercial CBCT devices with and without a lead apron present. Shielded and non-shielded exposures were compared under the paired Wilcoxon test, with absolute an…

Malemedicine.medical_specialtyCone beam computed tomographyEpidemiologyHealth Toxicology and MutagenesisCoefficient of variationRadiation DosageImaging phantom030218 nuclear medicine & medical imaging03 medical and health sciencesRadiation Protection0302 clinical medicinefashionSkin Physiological PhenomenaRadiography DentalHumansMedicineRadiology Nuclear Medicine and imagingReproducibilityDosimeterPhantoms Imagingbusiness.industryThyroidAbsorption RadiationEquipment Design030206 dentistryCone-Beam Computed TomographyRadiation ExposureEquipment Failure Analysismedicine.anatomical_structurefashion.garmentLead apronFemaleBody regionRadiologybusinessHealth Physics
researchProduct

Digital Tomosynthesis: A New Technique for Imaging Nephrolithiasis. Specific Organ Doses and Effective Doses Compared With Renal Stone Protocol Nonco…

2014

Objective To determine organ-specific doses (ODs) and effective dose (ED) for digital tomosynthesis (DT) and compare it with our institutional renal stone protocol noncontrast computed tomography (NCCT). Methods A validated anthropomorphic male phantom was placed supine on a digital GE Definium 8000 radiological scanner. Thermoluminescent dosimeters were placed in 256 locations and used to measure OD. A routine DT study was performed consisting of 2 scout images and 1 tomographic sweep in a 14.2-degree arc over the phantom. Software is used to recreate a series of coronal images from the sweep. ODs were determined as the sum of the doses for the study. Equivalent doses were calculated by mu…

Malemedicine.medical_specialtyRenal stoneSupine positionDosimetermedicine.diagnostic_testPhantoms Imagingbusiness.industryUrologyComputed tomographyNephrolithiasisRadiation DosageEffective dose (radiation)Imaging phantomTomosynthesisRadiographic Image EnhancementmedicineHumansTomographyRadiologyTomography X-Ray ComputedNuclear medicinebusinessUrology
researchProduct

Usability of Cr-Doped Alumina in Dosimetry

2019

Dosimetry is a widespread material science field dealing with detection and quantification of ionizing radiation using electronic processes in materials. One of the main aspects that determines the performance of dosimeters is the type of defects the material contains. Crystalline lattice imperfections are formed around impurity ions, which may have a smaller or larger size, or different oxidation states compared to host ions. In this study, we show what effects Cr impurities have on the luminescent properties of alumina. Porous Al 2 O 3 : Cr microceramics synthesized using the sol-gel method showed a higher thermoluminescence response than a single crystal ruby. We have found that Cr 2 O 3…

Materials scienceAnalytical chemistry02 engineering and technologyCrystal structureAl<sub>2</sub>O<sub>3</sub>: Cr010402 general chemistrylcsh:Chemical technology01 natural sciencesThermoluminescencelcsh:TechnologyImpurityDosimetrysol-gellcsh:TP1-1185Sol-gelDosimeterdosimetrylcsh:TGeneral Medicine021001 nanoscience & nanotechnologyalumina0104 chemical scienceschromium0210 nano-technologyLuminescenceSingle crystalCeramics
researchProduct

Diffusion and sensitivity characteristics of a chemically cross-linked PVA-Fricke gel dosimeter

2016

Materials scienceDosimeterBiophysicsAnalytical chemistryGeneral Physics and AstronomyRadiology Nuclear Medicine and imagingGeneral MedicineSensitivity (control systems)Diffusion (business)Fricke gelPhysica Medica
researchProduct

High-dose behaviour of CaSO4: Dy thermoluminescent phosphors as deduced by a continuous model for trap depths

1978

Abstract The high-dose behaviour of CaSO4: Dy TL dosimeters observed by some authors is compared with the one deduced by the continuous distribution of trap depths previously proposed by us. A general agreement results.

Materials scienceDosimeterContinuous modellingPhosphorGeneral MedicineTrap (plumbing)Atomic physicsThermoluminescenceNuclear Instruments and Methods
researchProduct

Fogging effect correction of Gafchromic HD-V2 film response for its use in high-dose radiotherapy

2020

GAFChromic® HD-V2 film is a reliable dose measurement device, thin, flexible, inexpensive, simple to use and easy to analyze. The response in terms of net absorbance with respect to absorbed dose was found to be linear in a large dose range, which supports the feasibility of using the film dosimeters in many applications, such as radiotherapy. For its use, a "fogging" effect must be take into account since film response changes with time. To determine a calibration curve valid for any time, fogging effect was investigated for more than 400 days. A correction procedure allows the use of HD-V2 film dosimeters in high-dose radiotheraphy, as brachytherapy, and quality assurance (QA) procedures.

Materials scienceDosimeterFoggingbusiness.industryCalibration curveSettore ING-IND/20 - Misure E Strumentazione Nuclearimedicine.medical_treatmentBrachytherapydosimetry GAFChromic film gamma radiation radiotherapy030218 nuclear medicine & medical imagingRadiation therapy03 medical and health sciences0302 clinical medicine030220 oncology & carcinogenesisAbsorbed dosemedicineDosimetrybusinessQuality assuranceBiomedical engineering
researchProduct

Influence of the simultaneous calibration of multiple ring dosimeters on the individual absorbed dose

2021

Abstract Ring dosimeters for personal dosimetry are calibrated in accredited laboratories following ISO 4037-3 guidelines. The simultaneous irradiation of multiple dosimeters would save time, but has to be carefully studied, since the scattering conditions could change and influence the absorbed dose in nearby dosimeters. Monte Carlo simulations using PENELOPE-2014 were performed to explore the need to increase the uncertainty of H p 0 .07 in the simultaneous irradiation of three and five DXT-RAD 707H-2 (Thermo Scientific) ring dosimeters with beam qualities: N-30, N-80 and N-300. Results show that the absorbed dose in each dosimeter is compatible with each of the others and with the refere…

Materials scienceDosimeterRadiation Dosimetersbusiness.industryMonte Carlo methodPublic Health Environmental and Occupational HealthCoverage probabilityGeneral Medicine030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineOptics030220 oncology & carcinogenesisAbsorbed doseCalibrationCalibrationDosimetryComputer SimulationIrradiationRadiometryCalibration ISO 4037 Monte Carlo Personal dosimetry Ring dosimetersbusinessMonte Carlo MethodWaste Management and DisposalBeam (structure)Journal of Radiological Protection
researchProduct

PbS Nanodots For Ultraviolet Radiation Dosimetry

2011

Lead sulfide (PbS) nanodots in Zirconia (ZrO2) thin film matrix (ZrO2:PbS films) were investigated for UV radiation dosimetry purposes. Samples were fabricated using sol-gel technique. ZrO2:PbS films were irradiated with UV light with wavelengths 250 – 400 nm during 50 minutes. Photoelectron emission spectra of ZrO2:PbS films were recorded and band structure for nonradiated and UV irradiated samples was calculated. It was found that quantity of localized states decreased after UV irradiation while density of localized states was dependent on concentration of PbS nanodots. The observed changes in band structure of ZrO2:PbS films after UV irradiation suggest that the films may be considered a…

Materials scienceDosimeterbusiness.industryAnalytical chemistryRadiationchemistry.chemical_compoundchemistryDosimetryOptoelectronicsCubic zirconiaLead sulfideIrradiationNanodotThin filmbusiness
researchProduct

Design and evaluation of a HDR skin applicator with flattening filter

2008

The purposes of this study are: (i) to design field flattening filters for the Leipzig applicators of 2 and 3 cm of inner diameter with the source traveling parallel to the applicator contact surface, which are accessories of the microSelectron-HDR afterloader (Nucletron, Veenendaal, The Netherlands). These filters, made of tungsten, aim to flatten the heterogeneous dose distribution obtained with the Leipzig applicators. (ii) To estimate the dose rate distributions for these Leipzig+filter applicators by means of the Monte Carlo (MC) method. (iii) To experimentally verify these distributions for prototypes of these new applicators, and (iv) to obtain the correspondence factors to measure t…

Materials scienceDosimeterbusiness.industrymedicine.medical_treatmentMonte Carlo methodBrachytherapyGeneral MedicineImaging phantomKermaOpticsIonization chamberCalibrationmedicineDosimetrybusinessNuclear medicineMedical Physics
researchProduct