Search results for "Dosimetry"

showing 10 items of 297 documents

Evaluation of lens absorbed dose with Cone Beam IGRT procedures

2015

The purpose of this work is to evaluate the absorbed dose to the eye lenses due to the cone beam computed tomography (CBCT) system used to accurately position the patient during head-and-neck image guided procedures. The on-board imaging (OBI) systems (v.1.5) of Clinac iX and TrueBeam (Varian) accelerators were used to evaluate the imparted dose to the eye lenses and some additional points of the head. All CBCT scans were acquired with the Standard-Dose Head protocol from Varian. Doses were measured using thermoluminescence dosimeters (TLDs) placed in an anthropomorphic phantom. TLDs were calibrated at the beam quality used to reduce their energy dependence. Average dose to the lens due to …

Cone beam computed tomographyDosimeterPhantoms Imagingbusiness.industryPublic Health Environmental and Occupational HealthTruebeamRadiotherapy DosageGeneral MedicineCone-Beam Computed Tomographyequipment and supplieslaw.inventionLens (optics)lawAbsorbed doseLens CrystallineThermoluminescent DosimetryMedicineThermoluminescent Dosimetrysense organsLaser beam qualitybusinessNuclear medicineHeadWaste Management and DisposalImage-guided radiation therapyJournal of Radiological Protection
researchProduct

Radiation dose in non-dental cone beam CT applications: a systematic review.

2018

Background: Radiation-induced health risks are broadly questioned in the literature. As cone beam computed tomography (CBCT) is increasingly used in non-dental examinations, its effective dose needs to be known. This study aimed to review the published evidence on effective dose of non-dental CBCT for diagnostic use by focusing on dosimetry system used to estimate dose. Materials and methods: A systematic review of the literature was performed on 12 November 2017. All the literature up to this date was included. The PubMed and web of science databases were searched. Studies were screened for inclusion based on defined inclusion and exclusion criteria according to the preferred reporting ite…

Cone beam computed tomographyRadiology Nuclear Medicine and ImagingComputed tomography dose indexCone beam computed tomographyRadiation DosageEffective dose (radiation)Imaging phantom030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineMedicineDosimetryHumansSkeletal imagingEffective dosebusiness.industry030206 dentistryGeneral MedicineCone-Beam Computed TomographyParanasal sinusesmedicine.anatomical_structureDose area productInclusion and exclusion criteriabusinessNuclear medicineHeadNeckHead and neck imagingHumanLa Radiologia medica
researchProduct

9 Development of an experimental tool to evaluate normal tissue 3D doses in external-beam radiotherapy

2018

Introduction Recently, cancer treatment improvement enabled an increase in patients’ survival rate. In more than half of the cases, radiotherapy participates in the cure for cancer. The efficacy of this technique is well known but it inevitably delivers doses to normal tissues exposing them to radio-induced complications risks [1] . Moreover, the longer patients’ life expectancy increases the risk of developing long-term complications such as second cancers. Thus, evaluating the risks following cancer treatment involving radiotherapy constitutes a major challenge. In this context, an experimental tool has been developed to evaluate normal tissue doses delivered by the different radiotherapy…

Contouringbusiness.industrymedicine.medical_treatmentBiophysicsGeneral Physics and AstronomyDose profileContext (language use)General MedicineGel dosimetryImaging phantom030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicinePlanned Dose030220 oncology & carcinogenesismedicineRadiology Nuclear Medicine and imagingExternal beam radiotherapyNuclear medicinebusinessRadiation treatment planningPhysica Medica
researchProduct

SU-FF-T-365: Practical Reconstruction Method for 3D CT-Based Brachytherapy with Shielded Colpostats

2006

Introduction and purpose.‐ The most extended worldwide HDR and PDR afterloading machines are from Nucletron, using the Plato Treatment Planning System (TPS) to perform the clinical dosimetry. The Fletcher‐Williamson (FW) vaginal colpostat applicators are widely used with these machines, they are made of a very dense material (densimet‐17) which allows shielding up to 50% of the dose. Almost all the TPS have incorporated the CT‐Based Brachytherapy (BT), in which the CT catheters and applicators reconstruction is based on contiguous CT transverse slices where the user points the catheter position. The problem with these applicators is the production of artefacts that makes the reconstruction …

Contouringmedicine.diagnostic_testComputer sciencebusiness.industrymedicine.medical_treatmentBrachytherapyComputed tomographyGeneral MedicineReconstruction methodImaging phantomlaw.inventionCatheterlawBreast implantShielded cablemedicineDosimetryClinical dosimetryRadiation treatment planningNuclear medicinebusinessMedical Physics
researchProduct

The 4th international comparison on EPR dosimetry with tooth enamel

2011

This paper presents the results of the 4th International Comparison of in vitro electron paramagnetic resonance dosimetry with tooth enamel, where the performance parameters of tooth enamel dosimetry methods were compared among sixteen laboratories from all over the world. The participating laboratories were asked to determine a calibration curve with a set of tooth enamel powder samples provided by the organizers. Nine molar teeth extracted following medical indication from German donors and collected between 1997 and 2007 were prepared and irradiated at the Helmholtz Zentrum Munchen. Five out of six samples were irradiated at 0.1, 0.2, 0.5, 1.0 and 1.5 Gy air kerma; and one unirradiated s…

Detection limitMolarRadiationChemistryCalibration curvebusiness.industryTooth enamelKermamedicine.anatomical_structurestomatognathic systemCalibrationmedicineEpr dosimetryDosimetryNuclear medicinebusinessInstrumentationRadiation Measurements
researchProduct

209 New Fricke gel with high sensitivity and low diffusion for 3D-MRI dosimetry

2018

Purpose Fricke gel (FG) dosimeters are good candidates for 3D dose assessment in biological materials. Their effective atomic number and density are similar to those of soft tissue. In view of their chemical and morphological characteristics, FG serve as dosimeters and as phantoms at the same time. FG dosimeters are obtained by incorporating an acidic aqueous solution of ferrous ions Fe2+ into a gel matrix. In order to address the limitations of gels based on natural matrices, we have studied FG produced with a matrix of poly-vinyl alcohol (PVA) cross-linked with glutaraldehyde (GTA). Materials and methods The proposed gel contains 10% w/v of PVA and GTA of 1%w/v. A common formulation agaro…

DosimeterMaterials scienceBiophysicsGeneral Physics and AstronomyGeneral MedicineImaging phantomchemistry.chemical_compoundchemistryIonization chamberAgaroseDosimetryRadiology Nuclear Medicine and imagingGlutaraldehydeIrradiationEffective atomic numberBiomedical engineeringPhysica Medica
researchProduct

Erratum: “TG-43 U1 based dosimetric characterization of model 67-6520 Cs-137 brachytherapy source”

2012

Purpose: Brachytherapy treatment has been a cornerstone for management of various cancer sites, particularly for the treatment of gynecological malignancies. In low dose rate brachytherapy treatments,C137s sources have been used for several decades. A new C137s source design has been introduced (model 67-6520, source B3-561) by Isotope Products Laboratories (IPL) for clinical application. The goal of the present work is to implement the TG-43 U1 protocol in the characterization of the aforementioned C137s source. Methods: The dosimetriccharacteristics of the IPLC137s source are measured using LiF thermoluminescent dosimeters in a Solid Water™ phantom material and calculated using Monte Carl…

DosimeterMaterials sciencebusiness.industrymedicine.medical_treatmentBrachytherapyMonte Carlo methodGeneral MedicineImaging phantomLow-Dose Rate BrachytherapyComputational physicsmedicineDosimetryNuclear medicinebusinessDose rateAnisotropyMedical Physics
researchProduct

Determination of New Radical Species in Ammonium Tartrate Dosimeters by CW- and Pulsed-EPR Techniques

2015

Samples of ammonium tartrate irradiated with doses of about 0.1–1 kGy by different beams of ionizing radiation (60Co–γ, 19 MeV protons and 62 MeV per nucleon carbon ions) were studied by continuous-wave electron paramagnetic resonance (cw-EPR) and by pulse-EPR techniques. Careful analysis of the cw-EPR and of the echo-detected EPR spectra allowed the identification of a second radical in the system besides the already known radical formed at high temperature by an hydrogen elimination at C(2) position [M. Brustolon et al., Res. Chem. Int 4:359, 1996]. The spectrum of the radical is compatible with that of a radical obtained by hydroxyl elimination.

Dosimeterammonium tartrateHydrogenPulsed EPRchemistry.chemical_elementAtomic and Molecular Physics and OpticsSpectral lineIonIonizing radiationlaw.inventionDosimetry; electron paramagnetic resonance; ammonium tartrateelectron paramagnetic resonancechemistrylawDosimetryPhysical chemistryIrradiationElectron paramagnetic resonanceNuclear chemistryApplied Magnetic Resonance
researchProduct

Technique for routine output verification of Leipzig applicators with a well chamber

2005

The H-type Leipzig applicators are accessories of the microSelectron-HDR system (Nucletron, Veenendaal, The Netherlands) for treatment of superficial malignancies. Recently, the dose rate distributions in liquid water for the whole set of applicators using both source models available for the microSelectron-HDR afterloaders have been obtained by means of the experimentally validated Monte Carlo (MC) code GEANT4. Also an output table (cGy/hU) at 3 mm depth on the applicator central axis was provided. The output verification of these applicators by the user, prior to their clinical use, present practical problems: small detectors such as thermoluminescent dosimeters or parallel-plate ionizati…

Dosimeterbusiness.industryComputer sciencemedicine.medical_treatmentBrachytherapychemistry.chemical_elementGeneral MedicineThermoluminescenceImaging phantomRadiation therapyOpticschemistryMedical imagingCalibrationmedicineDosimetryClinical dosimetryIridiumbusinessDose rateNuclear medicineMedical Physics
researchProduct

Pulsed EPR investigations on radiations dosimeters.

2009

Dosimetry Pulsed EPR radicalsSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct