ESR study of proton irradiation response of watch glasses.
2009
Electron Spin Resonance (ESR) dosimetry for clinical radiation beams.
2016
In the last two decades the electron spin resonance (ESR) technique has been widely adopted for dosimetry of the radiation beams used in radiation therapy. In particular, alanine dosimtery is nowadays recognized as an international standard system for transfer dosimetry and for high doses. This is because among the various solid-state dosimeters the alanine ESR detectors present several advantages such as: tissue equivalence, linearity of its dose-response over a wide range, high stability of radiation induced free radicals, no destructive read-out procedure, no sample treatment before EPR signal measurement. In this presentation the main applications of ESR dosimetry for the characterizati…
Uso della spettroscopia ESR per la caratterizzazione di composti fenolici irradiati con fasci clinici di fotoni ed elettroni
2016
In the last decades several research laboratories have shown an increasing interest aimed at extending the applicability of Electron Spin Resonance (ESR) dosimetry to radiotherapy with different types of radiation beams. ESR is a spectroscopic method for investigating the structure and dynamics of such paramagnetic species. Free radicals are known to be produced when a compound is irradiated with ionizing radiations. The concentration of radiation-induced free radicals is proportional to the energy released inside in the medium and this allows for dosimetric measurements through ESR technique which able to quantitatively determine the radical concentration. The use of alanine as a dosimetri…
Neutron Electron Spin Resonance dosimetry with phenol compounds
2014
Nuove frontiere per la dosimetria ESR per fasci clinici di fotoni ed elettroni: i composti fenolici IRGANOX® 1076. (Characterization of phenolic soli…
2017
This work deals with the dosimetric features of a particular phenolic compound (IRGANOX 1076®) for dosimetry of clinical photon and electron beams by using Electron Spin Resonance (ESR) spectroscopy. After the optimization of the ESR readout parameters (namely modulation amplitude and microwave power) to maximise the signal without excessive spectrum distortions, basic dosimetric properties of laboratory-made phenolic dosimeters in pellet form, such as reproducibility, dose-response, sensitivity, linearity and dose rate dependence were investigated. The dosimeters were tested by measuring the depth dose profile of a 6 MV photon beam. A satisfactory intra-batch reproducibility of the ESR sig…
Electron Spin Resonance dosimetry using organic compounds (alanine and ammonium tartrate) for mixed neutron-gamma fields
2016
Alongside with the development of Neutron Capture Therapy (NCT) and the use of thermal neutrons for radiotherapeutic purposes, many efforts have been devoted to the characterization of the beam in order to optimize therapy procedures. Reliable dose measurements should be able to determine the various (neutrons and photonic) components of the mixed beam usually employed for therapy. This paper studies the effect of additives such as boric and gadolinium nuclei on the sensitivity of neutron organic (alanine and ammonium tartrate) dosimeters analyzed through Electron Spin Resonance (ESR) technique (Marrale, 2014). These dosimeters were exposed to a mixed (neutron-gamma) field mainly composed o…
ESR response of alanine films exposed to low-energy (1-40 keV) X-rays
2018
Introduction L-a-alanine has aroused considerable interest for use in radiation ESR dosimetry. In this work, we examined the energy response of alanine ESR films in the low energy X-photon energy range between 1 keV and 40 keV. Dose measurements through a reference ionization chamber and a semiconductor detection system were also performed to complement ESR measurements. Methods Commercial alanine ESR films were used. All ESR signal measurements were also done using an XBand (9.7 GHz) Bruker spectrometer. The dosimeters were irradiated at the "Livio Scarsi" Laboratory (LAX) of the University of Palermo, where X-ray beams in the 1–40 keV energy range are produced using a Seifert SN60 tube. R…
The role of Electron Spin Resonance (ESR) spectroscopy in dosimetric and dating applications
2010
The use of gadolinium for ESR dosimetry
2010
The application of gadolinium to sensitize Electron Spin Resonance (ESR) dosimeters is reviewed. This nucleus is chosen because it has very good features in interacting with ionizing radiations. In particular, it has a very high capture cross section for thermal neutrons which favors the interactions of these particles within the detector; moreover, the charged secondary particles released after neutron interactions (mainly Auger and internal conversion electrons) are able to release their energy close the gadolinium site and, therefore, inside the sensitive volume of the detector. Consequently, the addition of gadolinium inside ESR dosimeters produces a significant enhancement of thermal n…
Monte Carlo simulation of energy absorbed in phenolic ESR dosimeters added with gadolinium exposed to thermal, epithermal and fast neutrons
2017
Abstract In this work analyses of the energy released per unit mass in phenolic compound exposed to neutron beams were performed with the aim of predicting the increase in dose achievable by addition of gadolinium (Gd) inside the pellets. In particular, Monte Carlo (MC) simulations were carried out for IRGANOX® 1076 phenolic compound irradiated with neutron beams with different energy spectra at various depths inside a water phantom. The addition of gadolinium increases sensitivity of phenolic ESR (electron spin resonance) dosimeters to neutrons thanks to the high gadolinium cross section for neutron capture and to the large number of secondary particles (mainly Auger and internal conversio…