Search results for "Drug-Eluting Stents"
showing 10 items of 36 documents
Initial experience with the novel BioMime 60 mm-long sirolimus-eluting tapered stent system in long coronary lesions
2017
Real world safety and efficacy of the Janus Tacrolimus-Eluting stent: long-term clinical outcome and angiographic findings from the Tacrolimus-Elutin…
2009
Objectives: We sought to evaluate the safety and performance of the Janus Tacrolimus-Eluting stent (TES) in an unselected population of patients, without application of restrictive clinical or angiographic criteria. Background: Continued attention to the safety, efficacy, and deliverability of first-generation drug eluting stents has led to the development of new antiproliferative agents with alternative stent platforms and different drug carrier vehicles. Methods: The TEST (Tacrolimus Eluting STent) registry is a prospective, nonrandomized single-center registry in which 140 consecutive patients who underwent single- or multi-vessel percutaneous coronary intervention between February 2005 …
Feasibility of Implanting 50-60 mm-Tapered Drug Eluting Stents in Chronic Total Occlusions.
2018
Abstract Background Percutaneous coronary intervention (PCI) of chronic total occlusions (CTO) usually involves multiple overlapping stents implantation to cover long coronary segments. A higher rate of restenosis has been described with stent overlapping. Recently, new long tapered stents emerged as a potential tool for treating long coronary lesions. Feasibility of using these new devices for the CTO PCI has not been described. The aim of this work was to describe our initial experience with 50 and 60 mm-long tapered sirolimus-eluting stents (SES) in CTO PCI. Methods We included 54 consecutive patients who underwent a CTO PCI and in whom an attempt to implant a 50 or 60 mm-long tapered SE…
Bioresorbable vascular scaffold versus everolimus-eluting stents or drug eluting balloon for the treatment of coronary in-stent restenosis: 1-Year fo…
2017
Objectives to compare the 1-year outcome between bioresorbable vascular scaffold (BVS), everolimus-eluting stent (EES), and drug-eluting balloon (DEB) for in-stent restenosis (ISR) treatment. Background BVS has been proposed as alternative for ISR treatment. To date a direct comparison between BVS and DES or DEB for ISR treatment is lacking. Methods We retrospectively analyzed all ISR lesions treated with BVS, DEB, and EES from January 2012 to December 2014. A total of 548 lesions (498 patients) were included. By applying two propensity-score matching, 93 lesions treated with BVS were compared with 93 lesions treated with DEB, and 100 lesions treated with BVS were compared to 100 lesions tr…
Long-term outcomes of percutaneous coronary interventions or coronary artery bypass grafting for left main coronary artery disease in octogenarians (…
2014
Percutaneous coronary intervention (PCI) with drug-eluting stents is an accepted alternative to surgery for the treatment of unprotected left main coronary artery (ULMCA) disease, but the long-term outcome in elderly patients is unclear. Aim of our study was to compare the clinical outcomes of octogenarians with ULMCA disease treated either with PCI with drug-eluting stents or coronary artery bypass grafting (CABG). The primary study end point was the composite of death, cerebrovascular accident, and myocardial infarction at follow-up. A total of 304 consecutive patients with ULMCA stenosis treated with PCI or CABG and aged 80 years were selected and analyzed in a large multinational regist…
Rational and design of the European randomized Optical Coherence Tomography Optimized Bifurcation Event Reduction Trial (OCTOBER)
2018
Background Percutaneous coronary intervention in complex bifurcation lesions is prone to suboptimal implantation results and is associated with increased risk of subsequent clinical events. Angiographic ambiguity is high during bifurcation stenting, but it is unknown if procedural guidance by intravascular optical coherence tomography (OCT) improves clinical outcome. Methods and design OCTOBER is a randomized, investigator-initiated, multicenter trial aimed to show superiority of OCT-guided stent implantation compared to standard angiographic-guided implantation in bifurcation lesions. The primary outcome measure is a 2-year composite end point of cardiac death, target lesion myocardial inf…
Impact of coronary calcification on outcomes after ABSORB scaffold implantation: insights from the GABI-R registry.
2020
OBJECTIVE To investigate the outcomes after bioresorbable scaffold (BRS) implantation in calcified coronary lesions. In calcified coronary lesions, durable metallic drug-eluting stent (DES) implantation is associated with worse clinical outcomes compared to noncalcified lesions. Although not recommended, BRSs were frequently implanted in calcified lesions in clinical practice. Their outcome is not well investigated. METHODS Between November 2013 and January 2016, 3326 patients were enrolled in the German-Austrian ABSORB ReglstRy (GABI-R). Lesion calcification severity was classified into no (n = 1144), mild (n = 1306), and moderate-to-severe (n = 690) calcification. RESULTS Patients with ca…
Safety and efficacy of biodegradable polymer-coated thin strut sirolimus-eluting stent vs. durable polymer-coated everolimus-eluting stent in patient…
2018
Introduction The biodegradable polymer drug-eluting stents were developed to improve vascular healing. However, further data are needed to confirm the safety and efficacy of these stents in patients with acute myocardial infarction (AMI). Aim We sought to determine the 1-year clinical follow-up in patients with AMI treated with a thin strut biodegradable polymer-coated sirolimus-eluting stent (BP-SES) versus a durable coating everolimus-eluting stent (DP-EES). Material and methods We analyzed patients with AMI (STEMI and NSTEMI) treated with either a BP-SES (ALEX, Balton, Poland, n = 886) or DP-EES (XIENCE, Abbott, USA, n = 1054) with available 1-year clinical follow-up using propensity sco…
Drug eluting and bare metal stents in people with and without diabetes: Collaborative network meta-analysis
2008
Objective To compare the effectiveness and safety of three types of stents (sirolimus eluting, paclitaxel eluting, and bare metal) in people with and without diabetes mellitus. Design Collaborative network meta-analysis. Data sources Electronic databases (Medline, Embase, the Cochrane Central Register of Controlled Trials), relevant websites, reference lists, conference abstracts, reviews, book chapters, and proceedings of advisory panels for the US Food and Drug Administration. Manufacturers and trialists provided additional data. Review methods Network meta-analysis with a mixed treatment comparison method to combine direct within trial comparisons between stents with indirect evidence fr…
Biodegradable polymer-coated thin strut sirolimus- -eluting stent versus durable polymer-coated everolimus-eluting stent in the diabetic population.
2021
Background: The number of patients with diabetes mellitus (DM) presenting with coronary artery disease is increasing and accounts for more than 30% of patients undergoing percutaneous coronary interventions (PCI). The biodegradable polymer drug-eluting stents were developed to improve vascular healing. It was sought herein, to determine 1-year clinical follow-up in patients with DM treated with the thin strut biodegradable polymer-coated sirolimus-eluting stent (BP-SES) versus durable coating everolimus-eluting stent (DP-EES). Methods: Patients were retrospectively analyzed with DM were treated with either a BP-SES (ALEX™, Balton, Poland, n = 670) or a DP-EES (XIENCE™, Abbott, USA, n = 884)…