Search results for "ECC"
showing 10 items of 2939 documents
Electromechanical delay in human skeletal muscle under concentric and eccentric contractions.
1979
In contraction of skeletal muscle a delay exists between the onset of electrical activity and measurable tension. This delay in electromechanical coupling has been stated to be between 30 and 100 ms. Thus, in rapid movements it may be possible for electromyographic (EMG) activity to have terminated before force can be detected. This study was designed to determine the dependence of the EMG-tension delay upon selected initial conditions at the time of muscle activation. The right forearms of 14 subjects were passively oscillated by a motor-driven dynamometer through flexion-extension cycles of 135 deg at an angular velocity of approximately equal to 0.5 rad/s. Upon presentation of a visual s…
[A gastric polypoid signet ring cell carcinoma]
2007
The authors signal a case of gastric polypoid signet ring cell carcinoma, of particular interest for its rarity like show from the review of the literature, which is the first to have been described after Tabaru's citation.The study has been carried out at the Department of Surgical and Oncological Sciences of the University of Palermo. It has been based on 2000 cases analysed from June 2001 to December 2003.The authors advance some and emphasizes the diagnostic flow chart and therapeutic choices adopted.We agree that the endoscopic polypectomy is surgical procedure of first approach, but modifying the therapeutic guideline in relation to histologic examination, like happened in the case in…
Prestretch potentiation of human skeletal muscle during ballistic movement
1981
The conditions associated prior to and during the transition from prestretch to shortening may have considerable influence on the final performance of muscle. In the present study male subjects of good physical condition performed vertical jumps on the force-platform with and without preliminary counter movement. In the counter movement jump (CMJ) the amplitude of the knee bending, velocity of the prestretch and the force attained at end of prestretch were the primary parameters of interest. In addition the coupling time indicating the transition from the eccentric (prestretch) phase to the concentric phase was recorded from the angular displacement and reaction force curves. In the final c…
Interaction between fascicle and tendinous tissues in short-contact stretch-shortening cycle exercise with varying eccentric intensities
2005
The interaction between fascicle and tendinous tissues (TT) in short-contact drop jumps (DJ) with three different drop heights [low (Low), optimal (OP), and high (High)] was examined with 11 subjects. The ground reaction force (F z) and ankle and knee joint angles were measured together with real-time ultrasonography (fascicle length) and electromyographic activities of the medial gastrocnemius (MG) and vastus lateralis (VL) muscles during the movement. With increasing drop height, the braking force and flight time increased from Low to OP ( P < 0.05). In High, the braking force increased but the flight time decreased compared with OP ( P < 0.05). During contact of Low and OP conditi…
Alterations of mechanical characteristics of human skeletal muscle during strength training
1983
To investigate the influence of strength training on the mechanical characteristics of human skeletal muscle, 14 male subjects went through training of combined heavy concentric and eccentric contractions three times a week for 16 weeks. The strength training program consisted mainly of dynamic exercises for leg extensors with loads of 80 to 120% of one maximum repetition. The force-time curves produced during various vertical jumps were the basis for calculation of various mechanical parameters. In addition to a great increase (p less than 0.001) in maximal isometric force, heavy resistance strength training also caused significant (p less than 0.05-0.01) increases in heights and in variou…
Efficacy and complications associated with a modified inferior alveolar nerve block technique. A randomized, triple-blind clinical trial
2014
Objectives: To compare the efficacy and complication rates of two different techniques for inferior alveolar nerve blocks (IANB). Study Design: A randomized, triple-blind clinical trial comprising 109 patients who required lower third molar removal was performed. In the control group, all patients received an IANB using the conventional Halsted technique, whereas in the experimental group, a modified technique using a more inferior injection point was performed. Results: A total of 100 patients were randomized. The modified technique group showed a significantly higher onset time in the lower lip and chin area, and was frequently associated to a lingual electric discharge sensation. Three f…
Comparative cytokeratin analysis of sweat gland ducts and eccrine poromas.
1991
Human eccrine sweat gland ducts and benign and malignant eccrine poromas were studied for the expression of various cytokeratins (CK) and vimentin by applying immunoperoxidase and immunofluorescence microscopy to frozen or paraffin-embedded sections, and using two-dimensional gel electrophoresis and immunoblotting. In acrosyringia and dermal eccrine ducts, the luminal cells exhibited intense staining for CKs 1/10/11 and 19. The periluminal cell layers of acrosyringia contained CKs 1/10/11, while CK 5 was absent. In contrast, the basal cell layer of dermal ducts was only positive with the antibody against CK 5, i. e. a pattern resembling that seen in epidermal basal cells. CK 9 was detected …
Force and EMG power spectrum during eccentric and concentric actions
2000
This study was designed to examine the force and activation levels of elbow flexor muscles during preactivated eccentric, concentric and isometric actions.Force, average EMG (aEMG), and the EMG power spectrum were investigated at different constant movement velocities (1 rad x s(-1), 2 rad x s(-1), 3 rad x s(-1), and 4 rad x s(-1)) at different joint angles.Average force at a 110 degree elbow angle was lower and aEMG was higher in concentric actions as compared with eccentric and isometric actions. At a 55 degree elbow angle, there was no difference in aEMG, or it was slightly higher in eccentric actions. MF was higher in the concentric as compared with eccentric actions at the three fastes…
Viscosity of the elbow flexor muscles during maximal eccentric and concentric actions.
1996
The aim of the present study was to estimate the damping coefficient (B factor) of the elbow flexor muscles during both eccentric and concentric muscle actions. We used a muscle model consisting of a viscous damper associated in parallel with a contractile component, both in series with an elastic component. The viscous damper allowed the concentric loss and the eccentric gain of force to be modelled. Eight volunteer subjects performed maximal eccentric and concentric elbow movements on an isokinetic dynamometer at angular velocities of 0.52, 1.04 and 2.09 rad*s(-1). Torques at an elbow joint angle of 90 degrees were recorded. Electromyogram (EMG) signals from the belly of the right elbow f…
Effect of electrode location on surface electromyography changes due to eccentric elbow flexor exercise.
2009
Experiments were carried out to determine whether the location of electrodes has an effect on eccentric exercise–induced changes in surface electromyography (sEMG) variables in the biceps brachii muscle. sEMG signals were recorded with a grid of 64 electrodes before and up to 4 days post-exercise. Root mean square (RMS) and mean power frequency (MNF) were calculated for: (1) each channel; (2) as an average of all channels; and (3) as an average of individual channel rows and columns. Mean muscle-fiber conduction velocity (CV) was estimated similarly but was based on double-differential channels. Maximal isometric voluntary torque decreased 21.3 ± 5.6% post-exercise. The average sEMG variabl…