Search results for "ELECTRODES"

showing 10 items of 231 documents

Ni-Fe alloy nanostructured electrodes for water splitting in alkaline electrolyser

2021

Abstract In this work, nickel-iron alloy nanostructured electrodes obtained by template electrosynthesis method are investigated for both hydrogen and oxygen evolution reactions. Electrodes consist of nanowire arrays with high surface area that are able to ensures a high electrolytic activity. To obtain different alloy compositions, the concentration of the elements in the deposition baths is appropriately tuned. Results show that the composition of nanowires does not change linearly with the composition of deposition bath but are richer in Fe. Nanostructured electrodes are tested as both cathodes and anodes in 30 wt% KOH aqueous solution, at room temperature to determine the best alloy com…

Tafel equationMaterials scienceAqueous solutionGeneral Chemical EngineeringAlloyOxygen evolution02 engineering and technologyElectrolyteengineering.material010402 general chemistry021001 nanoscience & nanotechnologyElectrosynthesisElectrochemistry01 natural sciences0104 chemical sciencesSettore ING-IND/23 - Chimica Fisica ApplicataChemical engineeringSettore ING-IND/17 - Impianti Industriali MeccaniciElectrochemistryengineeringWater splitting0210 nano-technologyAlkaline electrolyzer HER Nanostructured electrodes Ni-Fe Alloy OER Template electrosynthesis
researchProduct

Identification of atrial fibrillation drivers by means of concentric ring electrodes

2022

The prevalence of atrial fibrillation (AF) has tripled in the last 50 years due to population aging. High-frequency (DFdriver) activated atrial regions lead the activation of the rest of the atria, disrupting the propagation wavefront. Fourier based spectral analysis of body surface potential maps have been proposed for DFdriver identification, although these approaches present serious drawbacks due to their limited spectral resolution for short AF epochs and the blurring effect of the volume conductor. Laplacian signals (BC-ECG) from bipolar concentric ring electrodes (CRE) have been shown to outperform the spatial resolution achieved with conventional unipolar recordings. Our aimed was to…

TecnologiaAtrial FibrillationBody Surface Potential MappingHumansHealth InformaticsHeart AtriaElectrodesSistema cardiovascularComputer Science ApplicationsComputers in Biology and Medicine
researchProduct

Precursor Polymers for the Carbon Coating of Au@ZnO Multipods for Application as Active Material in Lithium-Ion Batteries

2014

The synthesis of statistical and block copolymers based on polyacrylonitrile, as a source for carbonaceous materials, and thiol-containing repeating units as inorganic nanoparticle anchoring groups is reported. These polymers are used to coat Au@ZnO multipod heteroparticles with polymer brushes. IR spectroscopy and transmission electron microscopy prove the successful binding of the polymer onto the inorganic nanostructures. Thermogravimetric analysis is applied to compare the binding ability of the block and statistical copolymers. Subsequently, the polymer coating is transformed into a carbonaceous (partially graphitic) coating by pyrolysis. The obtained carbon coating is characterized by…

Thermogravimetric analysisMaterials sciencePolymers and PlasticsPolymersInorganic chemistryAcrylic ResinsMetal NanoparticlesInfrared spectroscopyNanoparticleLithiumengineering.materialchemistry.chemical_compoundsymbols.namesakeElectric Power SuppliesMicroscopy Electron TransmissionCoatingMaterials ChemistryElectrodesIonschemistry.chemical_classificationOrganic ChemistryPolyacrylonitrileSpectrometry X-Ray EmissionElectrochemical TechniquesPolymerCarbonchemistryengineeringsymbolsGoldZinc OxideRaman spectroscopyPyrolysisMacromolecular Rapid Communications
researchProduct

A simple method for preoperative assessment of the best fitting electrode length in single lead VDD pacing.

1996

For single lead VDD pacing, electrodes with various distances between the lead tip and the floating atrial dipole (AV distance) are available. Using different AV distances allows positioning of the atrial dipole in the mid- to high right atrium, regardless of the size of the right heart. In this position, reliable atrial sensing and rejection of ventricular far-field potentials can be expected. A simple test for the preoperative assessment of the best fitting AV distance in the individual patient was tested. We studied 24 consecutive patients prior to implantation of a VDD pacemaker. With the patient in supine position, a test electrode with an AV distance of 13 cm was taped onto the thorax…

ThoraxAdultMalePacemaker ArtificialSupine positionmedicineFluoroscopyHumansHeart AtriaLead (electronics)AgedAged 80 and overmedicine.diagnostic_testbusiness.industryGeneral MedicineMiddle AgedElectrodes ImplantedDipoleSingle leadFluoroscopyElectrodeVdd pacingFemaleCardiology and Cardiovascular MedicinebusinessNuclear medicinePacing and clinical electrophysiology : PACE
researchProduct

Potential Application of Voltammetry of Microparticles for Dating Porcine Blood-based Binding Media used in Taiwanese Architectural Polychromies

2012

A method for dating Hemoglobine-containing archaeological samples using the voltammetry of microparticles is described. This is based on the record of the voltammetric response of such materials attached to paraffin-impregnated graphite electrodes in contact with aqueous acetate buffer. Signals attributable to the Fe(III)/Fe(II) iron couple and their catalytic enhancement in the presence of H(2)O(2) can be correlated, via first-order reaction kinetics, with the time of aging of the samples. The method has been applied to the study and dating of the polychromed architectural decoration of different parts of the architectural complex of the Longshan Temple in Lukang (18(th)  century, Taiwan).

Time FactorsAqueous solutionSwineChemistryOrganic ChemistryTaiwanAnalytical chemistryElectrochemical TechniquesHydrogen PeroxideGeneral ChemistryFerric CompoundsBiochemistryCatalysisGas Chromatography-Mass SpectrometryCatalysisHemoglobinsAnimalsGraphiteFerrous CompoundsElectrodesVoltammetryPorcine bloodGraphite electrodeNuclear chemistryChemistry - An Asian Journal
researchProduct

Hippocampal theta (3-8 Hz) activity during classical eyeblink conditioning in rabbits

2007

In 1978, Berry and Thompson showed that the amount of theta (3–8 Hz) activity in the spontaneous hippocampal EEG predicted learning rate in subsequent eyeblink conditioning in rabbits. More recently, the absence of theta activity during the training trial has been shown to have a detrimental effect on learning rate. Here, we aimed to further explore the relationship between theta activity and classical eyeblink conditioning by determining how the relative power of hippocampal theta activity [theta/(theta + delta) ratio] changes during both unpaired control and paired training phases. We found that animals with a higher hippocampal theta ratio immediately before conditioning learned faster a…

Time FactorsCognitive NeuroscienceCentral nervous systemeducationHippocampusExperimental and Cognitive PsychologyHippocampal formationElectroencephalographyHippocampusBehavioral Neurosciencemedicinedelay ehdollistaminenAnimalsLearninghippokampusEEGTheta Rhythmmedicine.diagnostic_testBehavior AnimalClassical conditioningConditioning EyelidClassical conditioningElectrodes ImplantedElectrophysiologymedicine.anatomical_structureEyeblink conditioningConditioningFemaleRabbitsPsychologyklassinen ehdollistaminenNeuroscienceDelay conditioning
researchProduct

Vitamin A deficiency increases noise susceptibility in guinea pigs.

1990

The effect of vitamin A deficiency in guinea pigs on noise-induced temporary threshold shift (TTS) was evaluated after short (15 min) acoustic overstimulation with a moderate (90 dB) broad-band white noise. Some guinea pigs were fed ad libitum a purified diet deficient in vitamin A (VAD group) until biochemical signs of deficiency occurred. A second, control group (VA group) received the same diet as well as 100 IU vitamin A daily by pharyngeal tube. Cochlear potentials were recorded by special computerized equipment using implanted electrodes. Before acoustic stimulation, a baseline value was determined with a test stimulus [90 dBA (A-filter according to usual DIN instructions)] correspond…

VitaminMalemedicine.medical_specialtyGuinea PigsMedicine (miscellaneous)StimulationAudiologyBiologychemistry.chemical_compoundRandom AllocationInternal medicineotorhinolaryngologic diseasesmedicineAnimalsInner earChromatography High Pressure LiquidAnalysis of VarianceNutrition and Dieteticsmedicine.diagnostic_testVitamin A DeficiencyRetinolAuditory ThresholdSignal Processing Computer-Assistedmedicine.diseaseCompound muscle action potentialAudiometry Evoked ResponseElectrodes ImplantedVitamin A deficiencymedicine.anatomical_structureEndocrinologychemistryAcoustic StimulationHearing Loss Noise-InducedEvoked Potentials Auditorysense organsAudiometryNoiseAuditory fatigueThe Journal of nutrition
researchProduct

Étude de la Dynamique des Ondes Spirales à l'Échelle Cellulaire par Modèles Expérimental et Numérique

2012

Among the death due to the cardiac problems, the arrhythmias play a major role, particularly the atrial disorders. This alarming situation attracts an intense research, but it is still limited by the availability of experimental models to reproduce the triggering mechanisms of arrhythmias at the cellular level and extensions of these anomalies. Whether they occur on a healthy or pathological heart, or they are benign or potentially dangerous (risk of sudden death), the arrhythmias constitute an important chapter of the cardiology. This thesis is interested in the studying and modeling of the arrhythmias at a cellular scale. Thus the problems of this thesis can be summarized briefly by the f…

[ INFO.INFO-TS ] Computer Science [cs]/Signal and Image Processing[INFO.INFO-TS] Computer Science [cs]/Signal and Image Processingmulti-electrodes arrayonde spirale[ SPI.SIGNAL ] Engineering Sciences [physics]/Signal and Image processingmodélisation cardiaquedynamique cardiaquestimulation sous-seuilspiral wavefibrillation atriale[INFO.INFO-TS]Computer Science [cs]/Signal and Image Processingcardiac dynamicsatrial fibrillationsub-threshold stimulationcardiac models[SPI.SIGNAL]Engineering Sciences [physics]/Signal and Image processing[SPI.SIGNAL] Engineering Sciences [physics]/Signal and Image processing
researchProduct

Nanostructured nickel–zinc alloy electrodes for hydrogen evolution reaction in alkaline electrolyzer

alkaline electrolyserSettore ING-IND/23 - Chimica Fisica ApplicataNickelgreen hydrogennanostructured electrodes
researchProduct

Description of Solid-to-Solid Redox Processes Based on the Voltammetry of Immobilized Particles Methodology: A Logistic Approximation

2022

A semiempirical model to describe the voltammetry of nontopotactic solid-to-solid redox processes occurring in the voltammetry of immobilized particles (VIMP) electrochemistry is described. It is applied to the reduction of solid metal compounds to the corresponding metal in contact with suitable electrolytes. The model is based on the assumption that the transferred charge is a logistic function of the applied potential, a situation that applies for reversible redox processes involving strongly adsorbed reactants. The model satisfactorily applies to reproduce linear potential scan curves recorded for graphite electrodes modified with different lead compounds (PbO, PbCl2·2H2O, lead-tin yell…

anode materialsGeneral Energycarbonredox reactionscharge transferUNESCO::CIENCIAS TECNOLÓGICASPhysical and Theoretical ChemistryelectrodesSurfaces Coatings and FilmsElectronic Optical and Magnetic MaterialsThe Journal of Physical Chemistry C
researchProduct