Search results for "ELECTROMYOGRAPHY"

showing 10 items of 672 documents

Neuromuscular changes after long-lasting mechanically and electrically elicited fatigue

2001

Central fatigue was investigated under an isolated active condition whereby the possible effects of supraspinal fatigue were minimized. Therefore, ten subjects were fatigued by simultaneously and repeatedly mechanically stretching and electrically stimulating their calf muscles for 1 h. This was performed using an ankle ergometer. The active fatigue task included a total of 2400 muscle stretches with an intensity of 10% of the maximal voluntary contraction (MVC). This protocol clearly impaired neuromuscular function, as revealed by a significant reduction in MVC (P < 0.01) and the neural input to the muscle (average EMG) (P < 0.01-0.001). The interpolated nerve stimulation compensated for t…

AdultMaleReflex Stretchmedicine.medical_specialtyPhysiologyNeuromuscular transmissionElectromyographyH-ReflexPhysiology (medical)Internal medicinemedicineHumansOrthopedics and Sports MedicineStretch reflexMuscle SkeletalMotor Neuronsmedicine.diagnostic_testElectromyographybusiness.industryPublic Health Environmental and Occupational HealthGeneral MedicineAnatomyMiddle AgedIntensity (physics)Electrophysiologymedicine.anatomical_structureTorqueMuscle FatigueReflexCardiologyAnklemedicine.symptombusinessAnkle JointMuscle ContractionMuscle contractionEuropean Journal of Applied Physiology
researchProduct

Reduced stretch reflex sensitivity and muscle stiffness after long-lasting stretch-shortening cycle exercise in humans

1998

It has been suggested that during repeated long-term stretch-shortening cycle (SSC) exercise the decreased neuromuscular function may result partly from alterations in stiffness regulation. Therefore, interaction between the short latency stretch-reflex component (M1) and muscle stiffness and their influences on muscle performance were investigated before and after long lasting SSC exercise. The test protocol included various jumps on a sledge ergometer. The interpretation of the sensitivity of the reflex was based on the measurements of the patellar reflexes and the M1 reflex components. The peak muscle stiffness was measured indirectly and calculated as a coefficient of the changes in the…

AdultMaleReflex Stretchmedicine.medical_specialtyPhysiologyPhysical ExertionElectromyographyH-ReflexWeight-BearingPhysiology (medical)Internal medicinemedicineHumansOrthopedics and Sports MedicineStretch reflexMuscle SkeletalSoleus musclemedicine.diagnostic_testMuscle fatigueElectromyographybusiness.industryPublic Health Environmental and Occupational HealthGeneral MedicineAnatomyMiddle AgedMuscle stiffnessmedicine.anatomical_structureMuscle FatigueCardiologyReflexmedicine.symptomH-reflexbusinessMuscle ContractionMuscle contractionEuropean Journal of Applied Physiology
researchProduct

Neuromuscular control in landing from supra-maximal dropping height.

2009

International audience; The present study utilized high-impact supra-maximal landings to examine the influence of the pre-impact force level on the post-impact electromyographic (EMG) activity and, in particular, on the short latency EMG reflex (SLR) component. Unilateral-leg landings were performed in a sitting position on a sledge apparatus after release from high, but individually constant dropping height. A lower limb guiding device fixed to the front of the sledge seat allowed the subjects to sustain a given pre-set force level up to impact. This force level was either freely chosen or set at 20, 35, and 50% of maximal isometric plantarflexion force. EMG activity was recorded from eigh…

AdultMaleReflex Stretchmedicine.medical_specialtyTime FactorsAdolescentPhysiologyShort latency stretch reflex[SDV]Life Sciences [q-bio]Movement03 medical and health sciencesYoung Adult0302 clinical medicinePhysical medicine and rehabilitationPhysiology (medical)Isometric ContractionReaction TimeMedicineHumansMuscle SkeletalUltrasonographyForce levelbusiness.industryElectromyographyProtective strategy030229 sport sciencesBiomechanical PhenomenaPre-programmed activationImpactLower ExtremityUltrasonographyNeuromuscular controlbusiness030217 neurology & neurosurgeryJournal of applied physiology (Bethesda, Md. : 1985)
researchProduct

Reduced stretch-reflex sensitivity after exhausting stretch-shortening cycle exercise.

1996

The stretch-shortening cycle (SSC) is an effective and natural form of muscle function but, when repeated with sufficient intensity or duration, it may lead to muscle damage and functional defects. A reduced tolerance to impact has been reported, which may be partly attributed to a reduced stretch-reflex potentiation. The aim of the present study was to examine the influence of SSC-induced metabolic fatigue and muscle damage on the efficacy of stretch reflexes, as judged by the electromyograph (EMG) response of two shank muscles (lateral gastrocnemius LG, soleus SOL) to controlled ramp stretches. These EMG responses were recorded before and immediately after exhausting SSC-type leg exercise…

AdultMaleReflex Stretchmedicine.medical_specialtyTime FactorsPhysiologyPhysical exerciseElectromyographySensitivity and Specificitychemistry.chemical_compoundPhysiology (medical)Internal medicinemedicineHumansOrthopedics and Sports MedicineStretch reflexExercise physiologyExercisebiologymedicine.diagnostic_testElectromyographyPublic Health Environmental and Occupational HealthGeneral MedicineAnatomyElectrophysiologymedicine.anatomical_structureEndocrinologyMyoglobinchemistryMuscle Fatiguebiology.proteinReflexCreatine kinaseEuropean journal of applied physiology and occupational physiology
researchProduct

Analysis of F response in upper motoneurone lesions

2009

The F response can provide a measure of motoneurone excitability (MNE) and so it may be used to investigate upper motoneurone disorders. This report studies the F-wave configuration in patients with stroke to evaluate the changes of the central excitability of the motoneurones at different times after an acute cerebral insult. Various parameters of the F response, including amplitude (absolute and F%/M), duration, and persistence have been determined in 26 patients with unilateral hemiplegia and in 32 healthy subjects of both sexes in the same age range. The investigation was carried out applying a series of 20 supramaximal stimuli at 0.5 Hz on tibial and ulnar nerves bilaterally. In all pa…

AdultMaleReflex Stretchmedicine.medical_specialtyWeaknessHemiplegiaPhysical examinationStimulationElectromyographyFunctional LateralityF waveInternal medicineReaction TimemedicineHumansTibial nerveStrokeUlnar NerveAgedAged 80 and overMotor Neuronsmedicine.diagnostic_testElectromyographyMusclesNeuromuscular DiseasesGeneral MedicineMiddle Agedmedicine.diseaseSurgeryCerebrovascular DisordersNeurologyMuscle TonusCardiologyReflexFemaleNeurology (clinical)Tibial Nervemedicine.symptomPsychologyActa Neurologica Scandinavica
researchProduct

Subthreshold low frequency repetitive transcranial magnetic stimulation selectively decreases facilitation in the motor cortex

2002

Objective: To investigate the modulatory effect of a subthreshold low frequency repetitive transcranial magnetic stimulation (rTMS) train on motor cortex excitability. Methods: The study consisted of two separate experiments. Subjects received a 10 min long subthreshold 1Hz rTMS train. In the first experiment, (single pulse paradigm), cortical excitability was assessed by measuring the amplitude of motor evoked potentials (MEPs) before and after the rTMS train. In the second experiment, a paired pulse paradigm was employed. Results: Corticospinal excitability, as measured by the MEP amplitude, was reduced by the rTMS train (experiment 1), with a significant effect lasting for about 10 min a…

AdultMaleRepetitive transcranial magnetic stimulationmedicine.medical_treatmentHuman motor cortexElectromyographyElectromagnetic FieldsPhysiology (medical)medicineHumansModulationmedicine.diagnostic_testElectromyographyPulse (signal processing)Subthreshold conductionmusculoskeletal neural and ocular physiologyMotor CortexMotor controlCortical excitabilityMiddle AgedEvoked Potentials MotorSensory SystemsIntra-cortical circuitsTranscranial magnetic stimulationElectrophysiologymedicine.anatomical_structurenervous systemNeurologyFacilitationFemaleNeurology (clinical)Nerve NetPsychologyNeuroscienceMotor cortexClinical Neurophysiology
researchProduct

Modulation of input–output curves by low and high frequency repetitive transcranial magnetic stimulation of the motor cortex

2002

Objectives: Exploring the modulatory effects of different frequencies of repetitive transcranial magnetic stimulation (rTMS) on the excitability of the motor cortex as measured by the input-output curve technique (I-O curve). Methods: Sixteen healthy subjects participated in this experiment. On two different sessions, conducted 1 week apart, rTMS was applied either at a frequency of 20 or 1Hz at 90% of individual motor threshold (MT) for a total of 1600 pulses each. Before and after rTMS, the cortical excitability was assessed by measuring MT and the size of motor evoked potentials (MEPs) collected at different intensities of stimulation. Results: The analysis on the whole population showed…

AdultMaleRepetitive transcranial magnetic stimulationmedicine.medical_treatmentPopulationCentral nervous systemStimulationbehavioral disciplines and activitiesPhysiology (medical)Modulation (music)medicineHumanseducationCerebral Cortexeducation.field_of_studyElectromyographyMotor CortexMotor controlCortical excitabilityInput-output curveEvoked Potentials MotorTranscranial Magnetic StimulationElectric StimulationSensory SystemsTranscranial magnetic stimulationElectrophysiologymedicine.anatomical_structureNeurologyFemaleNeurology (clinical)PsychologyNeuroscienceMotor cortexClinical Neurophysiology
researchProduct

Reanimation of the Paralyzed Human Larynx With an Implantable Electrical Stimulation Device

2003

Objectives/Hypothesis Electrical stimulation of the posterior cricoarytenoid muscle, when paced with inspiration, offers a physiological approach to restore ventilation in bilateral laryngeal paralysis without any of the disadvantages associated with conventional treatment. Study Design A prospective study of six patients. Methods The patients were successfully implanted with an Itrel II stimulator (Medtronic, Inc). In postoperative sessions, stimulated vocal fold abduction, patient ventilation, and voice were assessed and compared with preoperative values. Results The optimum stimulus paradigm was a 1- to 2-second train of 1-millisecond pulses delivered at a frequency of 30 to 40 Hz and am…

AdultMaleResuscitationmedicine.medical_specialtyElectric Stimulation TherapyStimulationVocal CordsLateralization of brain functionParalysismedicineHumansProspective StudiesHuman larynxProspective cohort studyAgedElectromyographybusiness.industryMouth BreathingProstheses and ImplantsMiddle Agedmedicine.diseaseSurgeryOtorhinolaryngologyPosterior cricoarytenoid muscleLaryngeal paralysisAnesthesiaFemaleLaryngeal Musclesmedicine.symptombusinessVocal Cord ParalysisInspiratory CapacityThe Laryngoscope
researchProduct

Force-, EMG-, and elasticity-velocity relationships at submaximal, maximal and supramaximal running speeds in sprinters.

1986

The relationships between ground reaction forces, electromyographic activity (EMG), elasticity and running velocity were investigated at five speeds from submaximal to supramaximal levels in 11 male and 8 female sprinters. Supramaximal running was performed by a towing system. Reaction forces were measured on a force platform. EMGs were recorded telemetrically with surface electrodes from the vastus lateralis and gastrocnemius muscles, and elasticity of the contact leg was evaluated with spring constant values measured by film analysis. Data showed increases in most of the parameters studied with increasing running speed. At supramaximal velocity (10.36 +/- 0.31 m X s-1; 108.4 +/- 3.8%) the…

AdultMaleSpecific forcePhysiologyElectromyographyPublic Health Environmental and Occupational HealthSTRIDEGeneral MedicineAnatomyConcentricElasticityBiomechanical PhenomenaRunningPhysiology (medical)EccentricHumansOrthopedics and Sports MedicineForce platformFemaleGround reaction forceBiomechanics of sprint runningLung ComplianceBiomedical engineeringResultant forceMathematicsEuropean journal of applied physiology and occupational physiology
researchProduct

Cardiorespiratory and Neuromuscular Responses to Motocross Riding

2008

The aim of the present study was to examine physiological and neuromuscular responses during motocross riding at individual maximal speed together with the riding-induced changes in maximal isometric force production. Seven A-level (group A) and 5 hobby-class (group H) motocross-riders performed a 30-minute riding test on a motocross track and maximal muscle strength and oxygen uptake (VO2max) tests in a laboratory. During the riding the mean (+/-SD) VO2 reduced in group A from 86 +/- 10% to 69 +/- 6% of the maximum (P < 0.001), whereas in group H the corresponding reduction was from 94 +/- 25% to 82 +/- 20% (P < 0.05). This relative VO2 during the riding correlated with riding speed (r = 0…

AdultMaleSpirometryMuscle Strength DynamometerAnaerobic ThresholdPhysiologyPhysical ExertionPoison controlPhysical Therapy Sports Therapy and RehabilitationMuscle Strength DynamometerElectromyographyIsometric exerciseSensitivity and SpecificityCohort StudiesOxygen ConsumptionHeart RateIsometric ContractionHeart ratemedicineHumansOrthopedics and Sports MedicineMuscle SkeletalMonitoring PhysiologicProbabilitymedicine.diagnostic_testElectromyographybusiness.industryCardiorespiratory fitnessGeneral MedicineMotorcyclesSpirometryAnesthesiaRespiratory Mechanicsbusinesshuman activitiesAnaerobic exerciseBlood Chemical AnalysisSportsJournal of Strength and Conditioning Research
researchProduct