Search results for "ELECTRONICS"
showing 10 items of 4340 documents
Cross-Spectrum PM Noise Measurement, Thermal Energy, and Metamaterial Filters.
2017
International audience; Virtually all commercial instruments for the measurement of the oscillator PM noise make use of the crossspectrum method (arXiv:1004.5539 [physics.ins-det], 2010). High sensitivity is achieved by correlation and averaging on two equal channels, which measure the same input, and reject the background of the instrument.We show that a systematic error is always present if the thermal energy of the input power splitter is not accounted for. Such error can result in noise underestimation up to a few decibels in the lowest-noise quartz oscillators, and in an invalid measurement in the case of cryogenic oscillators. As another alarming fact, the presence of metamaterial com…
Parabolic pulse evolution in normally dispersive fiber amplifiers preceding the similariton formation regime
2006
We show analytically and numerically that parabolic pulses and similaritons are not always synonyms and that a self-phase modulation amplification regime can precede the self-similar evolution. The properties of the recompressed pulses after SPM amplification are investigated. We also demonstrate that negatively chirped parabolic pulses can exhibit a spectral recompression during amplification leading to high-power chirp-free parabolic pulses at the amplifier output.
Dielectric metalenses with engineered point spread function
2017
High-index silicon nanoblocks support excitation of both electric and magnetic resonance modes at telecommunication wavelengths. At frequencies where both electric and magnetic resonance modes are excited simultaneously, changing the geometrical dimensions of the silicon cubes creates a 2π full span over the phase of the transmitted light in different amplitude ranges. We take advantage of the additional power-flux modulation of the scattered signal to focus the incident light with desired full width at half maximum (FWHM) and side lobe levels (SLLs) in both the lateral and axial directions. By implementing proper amplitude filters within the telecommunication working wavelength (1.55 μm), …
Resolution and field of view improvement in digital holography using a VCSEL source array
2011
We describe a new implementation capable to produce superresolution (SR) and object field of view (FOV) improvement in digital lensless Fourier holography. The method provides synthetic aperture (SA) generation using angular multiplexing incoming from a Vertical Cavity Surface Emitting Laser (VCSEL) source array. SR imaging in a single exposure is obtained after proper digital processing of a multiplexed hologram coming from the incoherent addition of multiple sub-holograms, each one corresponding with a different source of the VCSEL array. FOV improvement in addition with SR imaging is achieved by recording a set of individual holograms obtained by sequential activation of the VCSEL source…
Design and implementation of electronics and data acquisition system for Ultra-Fast Flash Observatory
2013
The Ultra-Fast Flash Observatory (UFFO) Pathfinder for Gamma-Ray Bursts (GRBs) consists of two telescopes. The UFFO Burst Alert & Trigger Telescope (UBAT) handles the detection and localization of GRBs, and the Slewing Mirror Telescope (SMT) conducts the measurement of the UV/optical afterglow. UBAT is equipped with an X-ray detector, analog and digital signal readout electronics that detects X-rays from GRBs and determines the location. SMT is equipped with a stepping motor and the associated electronics to rotate the slewing mirror targeting the GRBs identified by UBAT. First the slewing mirror points to a GRB, then SMT obtains the optical image of the GRB using the intensified CCD an…
Laser driven parametric amplification of xuv and soft-x-rays in neutral gases
2010
We present the first theoretical description and also experimental evidence for the amplification of XUV and soft-X-ray radiation by parametric stimulated emission in neutral gases driven by near-IR laser pulses reaching small-signal-gain up to 8000.
A compact system for high precision time measurements ( < 14 ps RMS) and integrated data acquisition for a large number of channels
2011
A high precision ( < 14 ps RMS time resolution) and high channel density ( ~ 256 channels) Time to Digital Converter (TDC) module (realized in FPGAs) with integrated DAQ is presented. The data is transported over up to 8 Gigabit-Ethernet or optical links with up to 3 Gb/s. Slow-Control information is transported over the same links. It can be attached directly to the detector, which allows the elimination of long cables and crate systems. The full 256 channel TDCs are expected to use approximately 30 W electrical power. The module size is 20 cm by 23 cm. Power is provided by a galvanically isolated 48 V low noise power supply. AddOn-boards adapt to the special needs of the detector to be re…
Acousto-optical multiple interference devices
2008
We present a new concept for waveguide acousto-optical devices based on coupled MachZehnder interferometers driven by acoustic waves. These acousto-optical multiple interference devices use the periodic refractive index modulation induced by the acoustic wave to realize functionalities such as ON/OFF switching for an arbitrary time interval, as well as for efficient light modulation at high harmonics of the acoustic frequency and pulse shaping for, e.g., integrated Q-switches. We also discuss application of the concepts to light modulation by very high acoustic frequencies, where the acoustic wavelengths become much shorter than the optical ones.
Multi-frequency super-scattering from sub-wavelength graphene-coated nanotubes
2019
A cylindrical multilayered structure with three coupled graphene shells is shown to behave as a dual-band super-scatterer at mid-infrared frequencies. Under the 2D plasmonic nature of graphene material, multiple scattering resonances are attained in the deep subwavelength regime using an isotropic material. In the proposed structure, we efficiently exploit the existing three plasmonic resonances in each scattering channel. These resonances are tailored by dispersion engineering, which is simply displayed through the Bohr model applied to the associated planar structure. For the super-scatterer design, it is essential that the resonances of multiple channels coincide in a single frequency. H…
Lab-based Ultrafast Molecular Structure
2010
The proliferation of various laser-driven approaches to sub-picosecond hard X-ray and short-wavelength radiation generation in the past few decades has opened many avenues for the laboratory-based development of traditionally facility-based short wavelength ultrafast molecular structure science. Together with the introduction of microcalorimeter detection schemes, this opens the floodgates to widespread, decentralized implementation of what were until recently specialist short wavelength techniques. A parallel situation exists for the contemporary adoption of sub-wavelength resolution optical microscopies. In what follows, a few ultrafast molecular structure developments and their rationale…