Search results for "ESOL"
showing 10 items of 2444 documents
The use of core-shell high-performance liquid chromatography column technology to improve biogenic amine quantification in wine
2015
BACKGROUND HPLC column technology has been improved, providing better resolution of closely eluting compounds, better analyte sensitivity, and shorter analysis times. The core-shell technology columns offer a faster analysis through the use of shorter columns without compromising resolution. The aim of this work was to improve the methods for determination of biogenic amines (BAs) in wine using the new HPLC PFP core-shell column technology. RESULTS Two different elution programs were designed to quantify BAs with the core-shell PFP column. Program I flow rate was 2 mL min−1. The total elution time was 10 min. In elution program II, the flow rate was 0.8 mL min−1 and the total elution time w…
Resolution of the ATLAS muon spectrometer monitored drift tubes in LHC Run 2
2019
The momentum measurement capability of the ATLAS muon spectrometer relies fundamentally on the intrinsic single-hit spatial resolution of the monitored drift tube precision tracking chambers. Optimal resolution is achieved with a dedicated calibration program that addresses the specific operating conditions of the 354 000 high-pressure drift tubes in the spectrometer. The calibrations consist of a set of timing offsets and drift time to drift distance transfer relations, and result in chamber resolution functions. This paper describes novel algorithms to obtain precision calibrations from data collected by ATLAS in LHC Run 2 and from a gas monitoring chamber, deployed in a dedicated gas fac…
Human Simulation: A Transdisciplinary Approach to Studying Societal Problems
2019
In this chapter, we present a transdisciplinary framework where humanities scholars, social scientists, and engineers can work together to tackle large and complex societal problems. We identify the steps required to construct a human simulation model and the concerns and issues that must be addressed to ensure success. We also present some basic definitions and assumptions inherent to developing this sort of model.
Multi-Resolution error analysis of predicted absorption coefficients. Method and application to the infrared spectrum of methane at high temperature.
2010
La version V2 inclut les modifications proposées par les reviewers.; International audience; A general method for the estimation of the confidence interval of molecular absorption coefficients is presented. Statistical numerical experiments are implemented to quantify the propagation of errors from line parameters to absorption coefficients or cross-sections as a function of the resolution. The method uses line parameter predictions (position and intensity) with estimated uncertainties derived from global polyad models. This work is especially intended to provide expert information for applications requiring theoretical predictions for which the present state of the art of line by line high…
Gradient design for liquid chromatography using multi-scale optimization.
2017
Abstract In reversed phase-liquid chromatography, the usual solution to the “general elution problem” is the application of gradient elution with programmed changes of organic solvent (or other properties). A correct quantification of chromatographic peaks in liquid chromatography requires well resolved signals in a proper analysis time. When the complexity of the sample is high, the gradient program should be accommodated to the local resolution needs of each analyte. This makes the optimization of such situations rather troublesome, since enhancing the resolution for a given analyte may imply a collateral worsening of the resolution of other analytes. The aim of this work is to design mul…
Enhanced calculation of optimal gradient programs in reversed-phase liquid chromatography
2003
Abstract The resolution of a mixture of 16 β-blockers under gradient elution was optimised using both isocratic and gradient training sets, with a reversed-phase column and acetonitrile–water eluents. Error theory was applied to measure the information extracted from different gradient experimental designs. This allows checking the expected accuracy when gradient predictions exceed the initial solvent concentrations tested in the training set. This work applies the results on modelling found in a previous study [J. Chromatogr. A 1018 (2003) 169] where the performance of several retention models was compared. Enhanced retention predictions were applied to the optimisation of gradient program…
A high-resolution layer-wise discontinuous Galerkin formulation for multilayered composite plates
2020
Abstract In this work, a novel high-resolution formulation for multilayered composite plates is presented. The formulations is referred to as high-resolution since it combines (i) Layer-Wise plate theories, which are based on a per-layer, high-order expansion of the primary variables throughout the plate’s thickness, providing a detailed layer-level description of the sought solution; (ii) The discontinuous Galerkin method, a numerical approach based on a discontinuous representation of the unknown fields over the mesh elements and on the introduction of boundary integral operators enforcing inter-element continuity, which allow the natural treatment of high-order mesh elements and provide …
Combined effect of solvent content, temperature and pH on the chromatographic behaviour of ionisable compounds.
2008
The organic solvent content and the pH in the mobile phase are the usual main factors in reversed-phase liquid chromatographic separations, owing to their strong effects on retention and/or selectivity. Temperature is often neglected. However, even in cases where the impact of this factor on selectivity is minor, the reduction in analysis time is still an interesting reason to consider it. In addition, ionisable compounds may exhibit selectivity changes, owing to the interaction of organic solvent and/or temperature with pH. The separation of ionisable compounds (nine diuretics: bendroflumethiazide, benzthiazide, bumetanide, chlorthalidone, furosemide, piretanide, probenecid, trichloromethi…
Modulation of retention and selectivity in oil-in-water microemulsion liquid chromatography: A review
2019
Microemulsions (MEs) are stable, isotropically clear solutions consisting of an oil and water stabilized by a surfactant and a co-surfactant. Oil-in-water microemuslion liquid chromatography (MELC) is a relatively new chromatographic mode, which uses an O/W ME as mobile phase. Retention, selectivity and efficiency can be modified by changing the concentration of the ME components and the ratio between the aqueous and oil phases. This work makes a critical survey on the information found in the literature about the mobile phase compositions that lead to the creation of successful O/W ME mobile phases, as well as the effect of pH for ionizable compounds and temperature. The viability of perfo…
Evaluation of the Effects of a Bullying at Work Intervention for Middle Managers.
2020
The aim of the study is to evaluate the effects of a workplace bullying intervention based on the training of middle managers regarding bullying awareness, the consequences of bullying, strategies in conflict resolution and mediation/negotiation abilities. Overall, 142 randomly selected middle managers participated in the study. First, participants completed an information record and two scales assessing bullying strategies, role conflict and role ambiguity. The last two scales were completed again in a second phase three months after the intervention had finished. The intervention produced a decrease in the following bullying strategies: effects on self-expression and communication, effect…