To transmit genes without becoming mother: An evolutionary conflict behind denial of pregnancy
2016
Aim: The etiology of pregnancy denial remains poorly understood. Neither necessary nor sufficient conditions can be synthesized from the risk factors identified from psychological analyses. In accordance with clinical observations, we aim to explain denial of pregnancy from an evolutionary conflict perspective. Methods: Authors investigate evolutionary biology aspects and emphasize on the transition from solitary animal species to social species. The possibility of conflicts between primitive species-perpetuation forces and subjective social-identity forces are explored. Results: As members of a social species, human beings have a dual, contradictory character of independent organisms but i…
Denoising 3D Models with Attributes using Soft Thresholding
2004
International audience; Recent advances in scanning and acquisition technologies allow the construction of complex models from real world scenes. However, the data of those models are generally corrupted by measurement errors. This paper describes an efficient single pass algorithm for denoising irregular meshes of scanned 3D model surfaces. In this algorithm, the frequency content of the model is assessed by a multiresolution analysis that requires only 1-ring neighbourhood without any particular parameterization of the model faces. Denoising is achieved by applying the soft thresholding method to the detail coefficients given by the multiresolution analysis. Our method is suitable for irr…
Anomalous d-like surface resonances on Mo(110) analyzed by time-of-flight momentum microscopy.
2015
The electronic surface states on Mo(110) have been investigated using time-of-flight momentum microscopy with synchrotron radiation (hν=35 eV). This novel angle-resolved photoemission approach yields a simultaneous acquisition of the E-vs-k spectral function in the full surface Brillouin zone and several eV energy interval. (kx,ky,EB)-maps with 3.4 A(-1) diameter reveal a rich structure of d-like surface resonances in the spin-orbit induced partial band gap. Calculations using the one-step model in its density matrix formulation predict an anomalous state with Dirac-like signature and Rashba spin texture crossing the bandgap at Γ¯ and EB=1.2 eV. The experiment shows that the linear dispersi…
Automated high-performance liquid chromatographic determination of amphetamine in biological fluids using column-switching and on-column derivatizati…
1999
A rapid and simple liquid-chromatographic method has been developed for on-line quantification of amphetamine in biological fluids. Untreated samples (20 μL) are injected directly into the chromatographic system and purified on a 20 mm×2.1 mm i.d. pre-column packed with 30 μm Hypersil C18 stationary phase. After clean-up the analyte is transferred to the analytical column (125 mm×4 mm i.d., 5 μm LiChrospher 100 RP18) for derivatization and separation using a mixture of acetonitrile and the derivatization reagent (o-phthaldialdehyde andN-acetyl-L-cysteine) as the mobile phase. The experimental conditions for on-line derivatization and resolution of the amphetamine have been optimized, and th…
Exploring hand-portable nano-liquid chromatography for in place water analysis: Determination of trimethylxanthines as a use case.
2020
Abstract Analytical performance and optimization of figures of merit of a portable nano liquid chromatograph (NanoLC) with UV detection at 255 nm have been established for in place analysis. Methylxanthines: caffeine, theophylline and theobromine were selected as target analytes. A fast lab method based on IT-SPME coupled on line with capillary liquid chromatograph (CapLC) with diode array detection (DAD) was employed for comparative studies. IT-SPME and solid phase extraction were coupled off-line to NanoLC for improving instrumental parameters, mainly detection capacity and selectivity. IT-SPME or SPE/portable NanoLC based methods were superior in terms of chromatographic resolution and o…
Sensitive determination of parabens in human urine and serum using methacrylate monoliths and reversed-phase capillary liquid chromatography-mass spe…
2014
A method for the determination of parabens in human urine and serum by capillary liquid chromatography (cLC) with UV-Vis and mass spectrometry (MS) detection using methacrylate ester-based monolithic columns has been developed. The influence of composition of polymerization mixture was studied. The optimum monolith was obtained with butyl methacrylate monomer at 60/40% (wt/wt) butyl methacrylate/ethylene dimethacrylate ratio and 50wt% porogens (composed of 36wt% of 1,4-butanediol, 54wt% 1-propanol and 10wt% water). Baseline resolution of analytes was achieved through a mobile phase of acetonitrile/water in gradient elution mode. Additionally, dispersive liquid-liquid microextraction (DLLME)…
Flow injection spectrophotometric determination of boron in ceramic materials.
1998
Abstract A flow injection spectrophotometric method for the determination of boron in ceramic materials is described. The method is based on spectrophotometric measurement of the decrease in the pH produced by the reaction between boric acid and mannitol in the presence of an acid-base indicator. A bichannel FI (flow injection) manifold in which the sample solutions were injected into deionized water (at pH 5.4) and the stream was later merged with the reagent stream (a mannitol solution containing 1×10 −4 mol l −1 bromocresol green at pH 5.4), was used. Transient signals were monitored at 616 nm. A theoretical model which describes the dependence between the absorbance values and boric aci…
Fourier transform infrared determination of Fluometuron in pesticide formulations
2003
Abstract A single method has been developed for Fourier transform infrared (FTIR) determination of Fluometuron in pesticide formulations. Samples were ultrasonically shaken with CHCl3 for 5 min and the FTIR spectra of sample extracts and standards were obtained at a nominal resolution of 4 cm−1 from 4000 to 900 cm−1 accumulating 25 scans. Fluometuron determination is based on the measure of peak area from 1342 to 1321 cm−1 corrected using a baseline defined from 1352 to 1294 cm−1. This procedure provided a limit of detection of 6.5 μg g−1, a sensitivity of 0.852 a.u. g mg−1 for a pathlength of 0.11 mm, a relative standard deviation of 1.6% for three analysis of a sample containing 50.4% (w/…
In situ derivatization for double confirmation of 2C–C in oral fluids by ion mobility spectrometry
2017
Ion mobility spectrometry (IMS) is a powerful tool to carry out quick and sensitive detection of illicit activities and has been employed for the determination of the psychedelic drug 2,5-dimethoxy-4 chlorophenethylamine (2C–C) in oral fluid samples. Saliva samples were extracted with chloroform and analysed by IMS reaching a limit of detection (LOD) of 14 μg L−1. Nevertheless, IMS has a scarce resolution and selectivity of the method can be often compromised by the presence of potential interferents with similar molecular weights and drift times. Thus, a rapid and in situ derivatization with acetone, to form the corresponding imine, has been proposed in the present study to confirm the pre…
COMPARATIVE STUDY OF C18- AND STYRENE-DIVINYLBENZENE-BASED SORBENTS FOR THE ENRICHMENT OF PHENOLS FROM WATER
2001
The potential of solid-phase extraction with C18- and styrene divinylbenzene-based sorbents for the preconcentration of phenols from water samples has been evaluated for a variety of phenols of different polarities: phenol, o-, m- and p-cresol, 2-chlorophenol, and 4-chloro-3-methylphenol. The extraction efficiencies have been calculated for different volumes of samples containing the analytes at different concentration levels. The UV limits of detection were of 1–5 ng/mL, for the method using Bond Elut C18 cartridges and sample volumes of 25 mL, and 0.05–0.1 ng/mL (except for 4-chloro-3-methylphenol) for the method using the polymeric sorbent Bond Elut PPL and 1000 mL of the samples. Possib…