Search results for "ESOL"
showing 10 items of 2444 documents
Fractal Dimension Logarithmic Differences Method for Low Voltage Series Arc Fault Detection
2021
Series arc faults introduce singularities in the current signal and changes over time. Fractal dimension can be used to characterize the dynamic behaviour of the current signal by providing a degree of signal chaos. This measure of irregularity exhibits changes in signal behaviour that can suitably be used as a basis for series arc fault detection. In this paper, an efficient low voltage series arc fault detection method based on the logarithmic differences of the estimate of the fractal dimension of the current signal using the multiresolution length-based method is presented. The discrete wavelet transform and the hard thresholding denoising with the universal threshold are also used. Exp…
Regularization of optical flow with M-band wavelet transform
2003
The optical flow is an important tool for problems arising in the analysis of image sequences. Flow fields generated by various existing solving techniques are often noisy and partially incorrect, especially near occlusions or motion boundaries. Therefore, the additional information on the scene gained from a sequence of images is usually worse. In this paper, discrete wavelet transform has been adopted in order to enhance the reliability of optical flow estimation. A generalization of the well-known dyadic orthonormal wavelets to the case of the dilation scale factor M > 2 with N vanishing moments has been used, and it has proved to be a useful regularizing tool. The advantages in the comp…
Performance of Spectral Fitting Methods for vegetation fluorescence quantification
2010
The Fraunhofer Line Discriminator (FLD) principle has long been considered as the reference method to quantify solar-induced chlorophyll fluorescence (F) from passive remote sensing measurements. Recently, alternative retrieval algorithms based on the spectral fitting of hyperspectral radiance observations, Spectral Fitting Methods (SFMs), have been proposed. The aim of this manuscript is to investigate the performance of such algorithms and to provide relevant information regarding their use. FLD and SFMs were used to estimate F starting from Top Of Canopy (TOC) fluxes at very high spectral resolution (0.12 nm) and sampling interval (0.1 nm), exploiting the O2-B (687.0 nm) and O2-A (760.6 …
Time-resolved luminescence of non-bridging oxygen hole centre in silica: Bulk and surface properties
2007
Q fever: a new ocular manifestation
2011
P Udaondo1,3, S Garcia-Delpech1,2, D Salom1,2, M Garcia-Pous1, M Diaz-Llopis1,21Department of Ophthalmology, Nuevo Hospital Universitario y Politecnico La Fe, Valencia, Spain; 2Faculty of Medicine, Universitat de València, Valencia, Spain; 3Universidad Cardenal Herrera CEU, Valencia, SpainAbstract: Q Fever is a zoonosis caused by Coxiella burnetii. Ocular manifestations are rare in this infection. We describe the case of a man complaining of an intense retro-orbital headache, fever, arthralgia, and bilateral loss of vision, who showed an anterior uveitis accompanied by exudative bilateral inferior retinal detachment and optic disk edema. At the beginning, a Vogt–Koyanag…
El crimen internacional de esclavitud sexual y la práctica de los «matrimonios forzados»
2015
El programa nuclear iraní, así como su evolución, ha sido un tema recurrente desde que se descubrió en 2002, siendo el foco de tensiones no sólo en el Medio Oriente, sino también a nivel internacional, ya que los retos que plantea son de gran enjundia, como lo ha puesto de relieve el Acuerdo de Viena del 24 de julio de 2015. The iranian nuclear programm, as well as its development, has been a recurrent topic since 2002, when it was discovered. Since then, it has been the focal point of strained relations between many countries, and not only of the Middle East, for the challenges created are with a lot of character, like the Agreement of 24 of July 2015.
Drift Time Measurement in the ATLAS Liquid Argon Electromagnetic Calorimeter using Cosmic Muons
2010
The ionization signals in the liquid argon of the ATLAS electromagnetic calorimeter are studied in detail using cosmic muons. In particular, the drift time of the ionization electrons is measured and used to assess the intrinsic uniformity of the calorimeter gaps and estimate its impact on the constant term of the energy resolution. The drift times of electrons in the cells of the second layer of the calorimeter are uniform at the level of 1.3% in the barrel and 2.8% in the endcaps. This leads to an estimated contribution to the constant term of (0.29-0.04+0.05)% in the barrel and (0.54-0.04+0.06)% in the endcaps. The same data are used to measure the drift velocity of ionization electrons …
Pre-Clinical Studies with D-Penicillamine as a Novel Pharmacological Strategy to Treat Alcoholism: Updated Evidences
2017
Ethanol, as other drugs of abuse, is able to activate the ventral tegmental area dopamine (VTA-DA) neurons leading to positively motivational alcohol-seeking behavior and use, and, ultimately to ethanol addiction. In the last decades, the involvement of brain-derived acetaldehyde (ACD) in the ethanol actions in the mesolimbic pathway has been widely demonstrated. Consistent published results have provided a mechanistic support to the use of ACD inactivating agents to block the motivational and reinforcing properties of ethanol. Hence, in the last years, several pre-clinical studies have been performed in order to analyze the effects of the sequestering ACD agents in the prevention of ethano…
Multi frequency phase fluorimetry (MFPF) for oxygen partial pressure measurement: ex vivo validation by polarographic clark-type electrode.
2013
BACKGROUND: Measurement of partial pressure of oxygen (PO2) at high temporal resolution remains a technological challenge. This study introduces a novel PO2 sensing technology based on Multi-Frequency Phase Fluorimetry (MFPF). The aim was to validate MFPF against polarographic Clark-type electrode (CTE) PO2 measurements. METHODOLOGY/PRINCIPAL FINDINGS: MFPF technology was first investigated in N = 8 anaesthetised pigs at FIO2 of 0.21, 0.4, 0.6, 0.8 and 1.0. At each FIO2 level, blood samples were withdrawn and PO2 was measured in vitro with MFPF using two FOXY-AL300 probes immediately followed by CTE measurement. Secondly, MFPF-PO2 readings were compared to CTE in an artificial circulatory s…
Observational Approach and Perspective
1983
Well you did not cover more than half of my planned talk! (laughter). Let me comment on interferometric techniques, in particular speckle imaging which you mentioned. Doing speckle imaging with the largest telescopes now available will not give you better than the theoretical resolving power of the telescope. With a 4m telescope that is about 30 marc sec in the visible. That happens to be the radius of the supergiant Betelguese. So you are not going to achieve much with speckle imaging on these stars. One technique which has not been adequately exploited is that of lunar occultation which can give much better angular resolution than speckle, of the order of 2-3 marc sec. By using suitably c…