Search results for "EYE"
showing 10 items of 2511 documents
Effect of contact lenses on ocular biometric measurements based on swept-source optical coherence tomography
2019
ABSTRACT Purpose: To determine the reliability of swept- source optical coherence tomography in cases in which soft contact lenses cannot be removed when acquiring biometric measurements. Methods: Eight subjects were included and only one eye per participant was analyzed. Each eye was measured six times by swept-source optical coherence tomography with the IOLMaster 700 instrument (Carl Zeiss Meditec, Jena, Germany). Axial length, central corneal thickness, anterior chamber depth, lens thickness, and keratometric measurements were evaluated for the naked eye and while wearing soft contact lenses of three different powers (-1.5, -3.0, and +2.0 D). Results: There were statistically significan…
Evaluation of the practicality of optical biometry and applanation ultrasound in 253 eyes
2003
Abstract Purpose To evaluate the percentage of eyes that could not be measured using optical biometry and ultrasound applanation and the reasons. Setting Department of Ophthalmology, Johannes Gutenberg-University Hospital, Mainz, Germany. Methods Optical biometry (IOLMaster®, Carl Zeiss Meditec AG) and A-scan ultrasound biometry were performed consecutively in 253 eyes scheduled for cataract surgery the next day. Lens opacities were evaluated with the Opacity Lensmeter (Interzeag), and a slitlamp examination and measurement of visual acuity were performed. The 2 techniques were compared in terms of the rate of and reasons for primary measurement failure. Results Measurement with the IOLMast…
Visual-motion suppression in congenital pendular nystagmus.
2009
Patients with a congenital pendular nystagmus are known not to experience oscillopsia in a normal visual environment. The data of a 31-year-old female patient suffering from a congenital pendular nystagmus are presented. The aim of the fluorodeoxyglucose positron emission tomography (FDG-PET) experiment was to analyze the regional cerebral glucose metabolism (rCGM) during minimal as well as maximal nystagmus. Video-oculography showed a maximum in frequency of the horizontal pendular nystagmus during gaze to the left, whereas the zone of minimal nystagmus was 10 degrees to the right. Two sessions with an 18F-fluorodeoxyglucose tracer were performed to analyze cerebral blood-glucose utilizati…
Thalamic infarctions cause side-specific suppression of vestibular cortex activations.
2005
H2O15-PET was performed during caloric vestibular stimulation of the right and left external ears in eight right-handed patients with acute unilateral infarctions or haemorrhages of the posterolateral thalamus (four right, four left). The posterolateral thalamus is the relay station for ipsi- and contralateral ascending vestibular input to the multiple multisensory vestibular cortex areas. The aim of this study was to evaluate the differential effects of unilateral vestibular thalamic lesions on thalamo-cortical projections, right hemispheric dominance and reciprocal inhibitory visual-vestibular interaction, as well as perceptual and ocular motor consequences during caloric irrigation. The …
Anatomical correlates of ocular motor deficits in cerebellar lesions
2009
Humans are able to stabilize the images of moving targets on the retina by means of smooth pursuit eye movements. After the pontine level, all smooth pursuit pathways pass through the cerebellum. Previous animal studies gave evidence that two specific lesion sites within the cerebellum cause smooth pursuit disorders: those of the flocculus/paraflocculus and the vermis including lobule VI, VII, the uvula and the deep cerebellar nuclei. To date, there have been only a few lesion studies in patients with smooth pursuit disorders that do not allow direct comparison with a control group. In the present study, new lesion mapping techniques determined which cerebellar structures were involved in p…
Central action of cinnarizine and flunarizine: A saccadic eye movement study
1994
The mechanism of action of flunarizine (FZ) and cinnarizine (CZ) on the CNS is not fully understood. Computer analysis of saccadic eye movements (SEM) provides a sensitive and objective method for evaluating drug effect on the function of specific brain structures. This study aimed to assess the effect of a single oral dose of FZ (20 mg) and CZ (150 mg) on CNS function by means of computer analysis of SEM. Ten healthy volunteers were studied according to a double-blind, cross-over, placebo-controlled design. Peak saccadic velocity (PSV), which is related to the function of a specific group of burst neurons located in the brain stem, was significantly reduced by FZ. No significant effect of …
Survival After Transplantation of Corneas From a Rabies-Infected Donor
2011
To examine the tissue samples of 2 corneal recipients from a rabies-infected donor for the presence of rabies to explain their survival.Interventional case series with a review of the literature. The explanted corneal donor buttons were examined via nested reverse transcriptase polymerase chain reaction. The patients were followed up ophthalmologically and neurologically. Antirabies antibodies were measured in blood samples, and skin biopsies were examined by direct fluorescent antibody staining.Two patients received corneas from the same multiorgan donor. Six weeks after transplantation, 3 of the donor's organ recipients became symptomatic and rabies virus was confirmed in tissue from the …
Coping with an acute psychosocial challenge: behavioral and physiological responses in young women.
2014
Despite the relevance of behavior in understanding individual differences in the strategies used to cope with stressors, behavioral responses and their relationships with psychobiological changes have received little attention. In this study on young women, we aimed at analyzing the associations among different components of the stress response and behavioral coping using a laboratory psychosocial stressor. The Ethological Coding System for Interviews, as well as neuroendocrine, autonomic and mood parameters, were used to measure the stress response in 34 young women (17 free-cycling women in their early follicular phase and 17 oral contraceptive users) subjected to the Trier Social Stress …
Visual performance of the Akreos Adapt AO intraocular lens in patients with different corneal profiles measured with an adaptive optics visual simula…
2012
AIMS: To evaluate the visual performance of an aberration-free intraocular lens (IOL) in patients with different corneal profiles using adaptive optics visual simulation. METHODS: A crx1 adaptive optics visual simulator was used to simulate the aberration pattern of an aberration-free IOL combined with five corneal profiles: virgin corneas and corneas with low and high myopic ablations and low and high hyperopic ablations. Ten eyes of 10 subjects were evaluated, and monocular distance visual acuity (VA) at 100%, 50% and 10% of contrast was measured. RESULTS: At 100% of contrast, no differences were found in VA values among virgin corneas, low and high myopic ablations and low hyperopic abla…
Effect of Simulated IOL Tilt and Decentration on Spherical Aberration After Hyperopic LASIK for Different Intraocular Lenses
2011
PURPOSE: To evaluate visual quality differences among intraocular lenses (IOLs) in patients with previous hyperopic laser ablations and to assess the impact of decentration and tilt of IOLs on visual quality. METHODS: An adaptive optics visual simulator was used to simulate the wavefront aberration pattern of one aberration-correcting IOL (AcrySof IQ SN60WF, Alcon Laboratories Inc) and two spherical IOLs with different amounts of positive spherical aberration (Akreos Adapt [Bausch & Lomb] and Triplato [AJL Ophthalmic]) in five situations—centered, 0.2 mm and 0.4 mm of decentration, and 2° and 4° of tilt—in two groups: simulated low hyperopic laser corneal ablation (low hyperopia group)…