Earthing system’s design in presence of non-uniform soil
2007
The authors propose a practical approach for facing the problem of the design of the earthing systems in two-layer soils. The approach is based on the calculation of an equivalent resistivity of the non-uniform soil through which the designer can treat this one as it was uniform. The purpose of the Authors is to provide an innovative simple method and some easy-to-use graphs for an easy earthing systems' design in two-layer soils.
Current and Voltage Behaviour During a Fault in a HV/MV System: Methods and Measurements
2015
When a single line to ground fault happens on the MV side of a HV/MV system, only a small portion of the fault current is injected into the ground by the ground-grid of the faulty substation. In fact the fault current is distributed between grounding electrodes and MV cables sheaths. In systems with isolated neutral or with resonant earthing this may be sufficient to provide safety from electric shock. Experimental measurements were performed on a real MV distribution network: a real single line to ground fault was made and fault currents were measured in the faulty substation and in four neighbouring substations. In this paper the problem of fault current distribution is introduced, the te…
Influence of LV neutral grounding on global earthing systems
2015
International Standards define a Global Earthing System as an earthing net created interconnecting local Earthing Systems (generally through the shield of MV cables and/or bare buried conductors). In Italy, the regulatory authority for electricity and gas requires distributors to guarantee the electrical continuity of LV neutral conductor. This requirement has led to the standard practice of realizing “reinforcement groundings” along the LV neutral conductor path and at users’ delivery cabinet. Moreover, in urban high-load scenarios (prime candidates to be part of a Global Earthing System), it is common that LV distribution scheme creates, through neutral conductors, an effective connection…
Fall of Potential Measurement of the Earth Resistance in Urban Environments: Accuracy Evaluation
2019
Both Standards EN 50522 and IEEE 81 propose the fall of potential method (FPM) to carry out the measurement of the resistance to earth ( $R_{\text{ES}}$ ) of an earthing system (ES). However, in urban areas, the recommended distances between the ES and auxiliary electrodes are not easy to respect, due to the presence of buildings and tarmac. Furthermore, unknown buried metallic parts and interconnections among ESs could modify the earth potential profile of the area, affecting the measurement results. In this paper, the key-issues that influence the measured $R_{\text{ES}}$ when the FPM is used in an urban environment are presented. A parametric analysis, carried out with Comsol Multiphysic…
Interconnections criteria of grounding grids in global grounding systems
2018
A Global Grounding System is defined as the combination of local grounding systems, obtained by their interconnection, which ensures, thanks to their proximity, that no dangerous touch voltages can arise. The interconnection of grounding systems via the armors of the MV cables, between secondary substations and HV/MV stations is herein analyzed to verify the effects on touch voltages in ground-fault conditions. In particular, two main issues are discussed: 1) the transfer of dangerous voltages to secondary substations, due to ground-faults occurring at the HV/MV station; 2) the reduction in the magnitude of the ground potential rise due to ground-fault conditions at secondary substations, t…
Risk indexes for studying interconnected earthing systems inside MV networks
2006
The paper presents a risk-evaluation-based approach to the issue of interconnection between the earth electrodes of the MV/LV substations within MV networks. After a short introduction on the interconnection between earthing systems, the paper proposes four risk indexes defined starting from the safety requirements given by CENELEC HD 63 7 S1. The indexes allow one to put in evidence, in a clear way, the benefits of the interconnection in terms of reduction of risk of critical electric shock for persons and of stress on the insulation of the LV devices in the presence of single line to earth faults and double earth faults inside MV/LV substations and single line to earth faults inside HV/MV…
A study on the use of bare buried conductors in an extended interconnection of earthing systems inside a MV network
2005
In the field of electrical safety an important topic is the transmission of voltages, during an earth fault, inside an extended interconnection of local earthing systems. The paper presents a study, with reference to the MV networks, about those systems where the interconnection between the earth electrodes of the electrical installations is carried out using bare buried conductors. Starting from the description of the circuital model of a bare buried conductor interconnecting together the earth electrodes of two MV/lv substations, the mathematical model of the whole interconnected earthing system is found. Finally, the results of some simulations, giving the distribution of the fault curre…
New circuital models of grounding systems and PDS for EMI analysis during a lightning strike
2005
In this paper circuital models of a Power Drive System (PDS) and of grounding systems are proposed in order to analyse Electromagnetic Interferences (EMI) induced in a PDS when a lightning current flows in the grounding system. The models have been developed adopting the network approach with lumped parameters and have been implemented using the software MATLAB. A High Frequency (HF) model suitable to simulate the impulse response of a PDS is described and a generalized method in order to calculate the lumped parameters values of grounding system models is presented. The new method takes into account the burial depth of electrodes as regards their length. The validation results of this new …
On multi-objective optimal reconfiguration of MV networks in presence of different grounding
2015
The present work faces the traditional multi-objective optimal reconfiguration problem of a distribution grid including the safety issue in the objective functions. Actually, in many medium voltage networks still transformers with ungrounded neutral and with resonant grounded neutral coexist in the same area. This may be sometimes cause of problems during a single-line-to-ground fault if the ground electrodes of one or more cabins, initially designed for satisfying the safety conditions in a resonant grounded neutral network, after the reconfiguration are in a grounded neutral one or vice versa. In the paper a safety objective function is defined and the Non dominated Sorting Genetic Algori…
Multiobjective Optimal Reconfiguration of MV Networks with Different Earthing Systems
2010
The paper deals with the traditional problem of multiobjective optimal reconfiguration applied to power distribution systems considering the safety issue in the formulation. The applications are devoted to the solution of the posed problem in networks in which coexist energy sources with unearthed neutral point and resonant earthed neutral point. After a brief review of the most recent papers on optimal reconfiguration, the paper outlines the safety problem and provides a solution to the multiobjective problem using the Non dominated Sorting Genetic Algorithm II aiming at: minimal power losses operation, safety check at distribution substations and load balancing among the HV/MV transformer…