Search results for "Eccentric"

showing 10 items of 182 documents

Force and EMG power spectrum during and after eccentric and concentric fatigue.

2000

Eccentric and concentric force and median frequency of the EMG power spectrum were measured during and immediately after maximal eccentric (EE) and concentric (CE) exercise and during the recovery period of 1 week. Eight male subjects performed EE and CE consisting of 100 maximal eccentric and concentric actions with elbow flexors during two separate exercise sessions. When comparing maximal eccentric and concentric actions before the exercises, the average force was higher (P<0.001) in eccentric than in concentric but the average rectified EMG (aEMG) values were the same with the two types of action. The average eccentric force decreased 53.3% after EE and 30.6% after CE, while the average…

AdultMalemedicine.medical_specialtyBiophysicsNeuroscience (miscellaneous)ElectromyographyConcentricBicepsMedian frequencyInternal medicinemedicineEccentricHumansLactic AcidExercise physiologyMuscle SkeletalCreatine KinaseExerciseMuscle fatiguebiologymedicine.diagnostic_testbusiness.industryElectromyographyMuscle FatiguePhysical therapyCardiologybiology.proteinCreatine kinaseNeurology (clinical)businessJournal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology
researchProduct

Motor Unit Firing Behaviour of Soleus Muscle in Isometric and Dynamic Contractions

2012

Introduction. Understanding the detailed control of human locomotion and balance can be improved, when individual motor units can be isolated and their firing rates followed in natural movement of large, fuctionally important muscles. For this reason the present study investigated the motor unit discharge rate (MUDR) in isometric and dynamic contractions of the soleus muscle. Methods: Eleven males performed isometric (10–100% MVC) and dynamic (10–40% MVC) plantar flexions. Intramuscular EMG was measured from Soleus with bipolar wire-electrodes and decomposed with custom built “Daisy” software. Results. The Soleus MUDR was significantly higher in concentric compared to isometric or eccentric…

AdultMalemedicine.medical_specialtyContraction (grammar)Anatomy and PhysiologyDynamicBiophysicslcsh:MedicineElectromyographyIsometric exerciseConcentricPhysical medicine and rehabilitationDiagnostic MedicineSoleusIsometric ContractionmedicineEccentricHumansBiomechanicsIsometricta315lcsh:ScienceMuscle SkeletalBiologyMusculoskeletal SystemSoleus muscleMotor NeuronsClinical NeurophysiologyIntramuscularMultidisciplinarymedicine.diagnostic_testChemistryElectromyographyMotor unitPhysicslcsh:Rfood and beveragesAnatomymusculoskeletal systemMotor unitelektromyografiaTorqueMedicinelcsh:Qmedicine.symptomMuscle contractionMuscle ContractionResearch Article
researchProduct

Multi-channel electromyography during maximal isometric and dynamic contractions.

2013

Motor unit behavior differs between contraction types at submaximal contraction levels, however is challenging to study during maximal voluntary contractions (MVCs). With multi-channel surface electromyography (sEMG), mean physiological characteristics of the active motor units can be extracted. Two 8-electrode sEMG arrays were attached on biceps brachii muscle (one on each head) to examine behavior of sEMG variables during isometric, eccentric and concentric MVCs of elbow flexors in 36 volunteers. On average, isometric (364 ± 88N) and eccentric (353 ± 74N) MVCs were higher than concentric (290 ± 73N) MVC (p0.001). Mean muscle fiber conduction velocity (CV) was highest during eccentric MVC …

AdultMalemedicine.medical_specialtyContraction (grammar)ElbowPhysical ExertionBiophysicsNeuroscience (miscellaneous)Action PotentialsIsometric exerciseElectromyographyConcentricPhysical medicine and rehabilitationmedicineEccentricHumansmultichannel EMG; dynamic contractions; isometric contractionsdynamic contractionsta315Muscle SkeletalMathematicsisometric contractionsmedicine.diagnostic_testElectromyographyMotor controlAnatomyMotor unitmedicine.anatomical_structuremultichannel EMGPhysical EnduranceNeurology (clinical)Muscle ContractionJournal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology
researchProduct

Impaired action potential conduction at high force levels after eccentric exercise

2010

High-density surface electromyography was used to examine whether gross sarcolemmal function is impaired in m. biceps brachii after intensive eccentric elbow flexor exercise, when measured at wide range of isometric contraction levels. Root mean square (RMS), mean power frequency (MNF) and mean muscle fibre conduction velocity (CV) were calculated before and up to four days post-exercise. Maximal isometric voluntary (MVC) force decreased by 21.3+/-5.6% two hours after exercise, and by 12.6+/-11.1% two days post-exercise. CV and MNF decreased both during MVC (CV from 4.1+/-0.3m/s to 3.8+/-0.4m/s and MNF from 92.6+/-10 Hz to 85.2+/-11 Hz) and during electrically evoked maximal M-wave (CV from…

AdultMalemedicine.medical_specialtyContraction (grammar)Physical ExertionNeural ConductionBiophysicsNeuroscience (miscellaneous)Action PotentialsIsometric exerciseElectromyographyBicepsRoot mean square03 medical and health sciences0302 clinical medicineInternal medicinemedicineHumansEccentricMuscle Skeletalmedicine.diagnostic_testMuscle fatigueChemistry030229 sport sciencesAnatomyMuscle FatiguePhysical EnduranceCardiologyFemaleStress MechanicalNeurology (clinical)medicine.symptom030217 neurology & neurosurgeryMuscle ContractionMuscle contractionJournal of Electromyography and Kinesiology
researchProduct

Isokinetic elbow flexion and coactivation following eccentric training.

1999

The influence of an eccentric training on torque/angular velocity relationships and coactivation level during maximal voluntary isokinetic elbow flexion was examined. Seventeen subjects divided into two groups (Eccentric Group EG, n = 9 Control Group CG, n = 8) performed on an isokinetic dynamometer, before and after training, maximal isokinetic elbow flexions at eight angular velocities (from - 120 degrees s(-1) under eccentric conditions to 240 degrees s(-1) under concentric conditions), and held maximal and submaximal isometric actions. Under all conditions, the myoelectric activities (EMG) of the biceps and the triceps brachii muscles were recorded and quantified as the RMS value. Eccen…

AdultMalemedicine.medical_specialtyElbowBiophysicsNeuroscience (miscellaneous)Isometric exerciseElectromyographyConcentricBicepsPhysical medicine and rehabilitationReference ValuesIsometric ContractionmedicineElbowEccentricHumansMuscle SkeletalExerciseMathematicsmedicine.diagnostic_testElectromyographyCoactivationBiomechanical Phenomenamedicine.anatomical_structureEccentric trainingPhysical therapyNeurology (clinical)Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology
researchProduct

Re-examination of training effects by electrostimulation in the human elbow musculoskeletal system.

2000

This study examines the effects of a 7 weeks sub-maximal training period of electrostimulation on the maximal isometric, concentric, eccentric voluntary torque and muscle contractile properties of the elbow flexor muscles of nine subjects. The daily program consisted of five series of six 6-s isometric actions (60 to 70% of maximal isometric voluntary action) at an elbow angle of 90 . After training the maximal voluntary isometric flexion torque increased significantly whereas the maximal voluntary isometric extension torque decreased significantly. Increases in isometric flexion torque were linked to an increase of the myoelectrical activity of the biceps brachii muscle. Under dynamic cond…

AdultMalemedicine.medical_specialtyElbowPhysical Therapy Sports Therapy and RehabilitationElectromyographyIsometric exerciseConcentricPhysical medicine and rehabilitationIsometric ContractionmedicineElbowTorqueEccentricHumansOrthopedics and Sports MedicineMuscle SkeletalMotor NeuronsAnalysis of Variancemedicine.diagnostic_testbusiness.industryElectromyographyBiomechanicsAnatomymusculoskeletal systemAdaptation PhysiologicalElectric StimulationElectrophysiologymedicine.anatomical_structureTorquePhysical FitnessbusinessInternational journal of sports medicine
researchProduct

The Effects of a Prolonged Running Exercise on Strength Characteristics

2000

The aim of this study was to examine concentric, isometric, and eccentric strength reductions in the quadriceps muscle following a prolonged running exercise. Before and after a 2 h run (28.4+/-1.4 km) peak torque (PT) of the knee extensors at angular velocities of -120, -90, -60, 0, 60, 120, 180, 240 degrees x s(-1) using an isokinetic dynamometer, electromyographic (EMG) activity of the vastus lateralis (VL) and vastus medialis (VM) muscles and height of a counter movement jump were recorded in twelve well-trained triathletes. Counter movement jump performances decreased by 10% and PT values were all significantly lower (p < 0.01) at each angular velocity following the run. The torque los…

AdultMalemedicine.medical_specialtyErgometryVastus medialisMovementPhysical Therapy Sports Therapy and RehabilitationIsometric exerciseElectromyographyConcentricRunningInternal medicinemedicineHumansEccentricKneeOrthopedics and Sports MedicineMuscle Skeletalmedicine.diagnostic_testElectromyographyChemistryBiomechanicsQuadriceps muscleAnatomyBiomechanical PhenomenaTorquePhysical EnduranceCardiologymedicine.symptomMuscle ContractionMuscle contractionInternational Journal of Sports Medicine
researchProduct

Region-dependent hamstrings activity in Nordic hamstring exercise and stiff-leg deadlift defined with high-density electromyography

2018

Recent studies suggest region-specific metabolic activity in hamstring muscles during injury prevention exercises, but the neural representation of this phenomenon is unknown. The aim of this study was to examine whether regional differences are evident in the activity of biceps femoris long head (BFlh) and semitendinosus (ST) muscles during two common injury prevention exercises. Twelve male participants without a history of hamstring injury performed the Nordic hamstring exercise (NHE) and stiff-leg deadlift (SDL) while BFlh and ST activities were recorded with high-density electromyography (HD-EMG). Normalized activity was calculated from the distal, middle, and proximal regions in the e…

AdultMalemedicine.medical_specialtyHamstring musclesFuture studiesQP301.H75_Physiology._Sport.High densityPhysical Therapy Sports Therapy and RehabilitationHamstring MusclesElectromyographyBiceps03 medical and health sciencesYoung Adultelectrical activity0302 clinical medicinemedicineEccentricHumansOrthopedics and Sports Medicineta315ExercisevoimanostoHamstring injurymedicine.diagnostic_testlihasaktiivisuusbusiness.industryElectromyographymuscle functionreidet030229 sport sciencesmedicine.diseasebi-articular hamstringsQPAthletic InjuriesPhysical therapyExercise Testvoimaharjoittelubusiness030217 neurology & neurosurgeryHamstringScandinavian Journal of Medicine and Science in Sports
researchProduct

Neuromuscular Behaviour of the Triceps Surae Muscle-Tendon Complex during Running and Jumping

2003

The present study examined the behaviour of the Achilles tendon (AT) - triceps surae (TS) muscle complex during running and long jump take-off. High AT forces were measured in the push-off phase in running even with very low EMG activity. In the long jump, high rate of stiffness development was a characteristic of the braking phase of the jump. The results suggest that high and well-coordinated activation patterns of the leg extensor muscles during the preactivation and eccentric phases together with high stretching velocities of muscle-tendon complex provide basis for appropriate tendomuscular stiffness. This together with high force at the end of the eccentric phase enables an effective p…

AdultMalemedicine.medical_specialtyMaterials scienceNeuromuscular JunctionNeuromuscular transmissionPhysical Therapy Sports Therapy and RehabilitationElectromyographymedicine.disease_causeAchilles TendonRunningJumpingPhysical medicine and rehabilitationTriceps surae muscleTask Performance and AnalysismedicineHumansEccentricOrthopedics and Sports MedicineMuscle SkeletalLegAchilles tendonmedicine.diagnostic_testElectromyographyAnatomymusculoskeletal systemBiomechanical PhenomenaTendonbody regionsmedicine.anatomical_structureJumpInternational Journal of Sports Medicine
researchProduct

Motor unit activation patterns during isometric, concentric and eccentric actions at different force levels.

2002

Motor unit activation patterns were studied during four different force levels of concentric and eccentric actions. Eight male subjects performed concentric and eccentric forearm flexions with the movement range from 100 degrees to 60 degrees in concentric and from 100 degrees to 140 degrees elbow angle in eccentric actions. The movements were started either from zero preactivation or with isometric preactivation of the force levels of 20, 40, 60 and 80% MVC. The subjects were then instructed to maintain the corresponding relative force levels during the dynamic actions. Intramuscular and surface EMG was recorded from biceps brachii muscle. Altogether 28 motoneuron pools were analyzed using…

AdultMalemedicine.medical_specialtyMovementBiophysicsNeuroscience (miscellaneous)Isometric exerciseElectromyographyConcentricSupinationPhysical medicine and rehabilitationForearmIsometric ContractionmedicineEccentricHumansElbow angleMuscle SkeletalMathematicsMotor Neuronsmedicine.diagnostic_testElectromyographyAnatomySpike amplitudeMotor unitmedicine.anatomical_structureNeurology (clinical)Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology
researchProduct