Search results for "Elastic"
showing 10 items of 2162 documents
Measurements of $R^{d}-R^{p}$ and $R^{Ca}-R^{C}$ in deep inelastic muon scattering
1992
Results are presented on the difference in R, the ratio of longitudinally to transversely polarised virtual photon absorption cross sections, for the deuteron and the proton. They are obtained by c ...
Time-of-flight ERD with a 200mm2 Si3N4 window gas ionization chamber energy detector
2014
Abstract Low energy heavy ion elastic recoil detection work has been carried out in Jyvaskyla since 2009 using home made timing detectors, a silicon energy detector and a timestamping data acquisition setup forming a time-of-flight–energy telescope. In order to improve the mass resolution of the setup a new energy detector was designed to replace the silicon solid state detector, which suffered from radiation damage and had poor resolution for heavy recoils. In this paper the construction and operation of an isobutane filled gas ionization chamber with a 14 × 14 mm 2 100 nm thick silicon nitride window are described. In addition to greatly improved energy resolution for heavy ions, the dete…
Rayleigh scattering of Mössbauer radiation on a myoglobin single crystal
1992
The RSMR technique was used to determine the fraction of radiation which is scattered elastically and inelastically, respectively, into Bragg reflections of a metmyoglobin single crystal. From this measurement 〈x2 1c〉=0.027±0.008 A2 has been determined which is due to long range correlated motions in analogy to acoustic and optic modes in solids.
Depth resolution optimization for low-energy ERDA
2007
Abstract With the implementation of low-energy time-of-flight Elastic Recoil Detection Analysis (ERDA), routine analysis of thin films with high depth resolution becomes possible. The optimization of the measurement conditions is a key issue for an accurate sample characterization and is normally a compromise among depth resolution, mass resolution and sensitivity, for a given sample. In this work, we focus on the depth resolution optimization, presenting an extensive study of two different materials, SiO 2 and TiN, representative of light and medium mass targets. The film thickness varies between 10 and 50 nm. The samples were measured with different beams ( 35 Cl, 63 Cu, 79 Br and 127 I),…
Time-of-flight telescope for heavy-ion RBS
2007
Abstract This paper describes a time-of-flight (TOF) spectrometer for Heavy-Ion Rutherford Backscattering Spectrometry (HI-RBS) recently installed at IMEC for thin film analysis. The TOF telescope allows the use of ion beams heavier than He, with advantages in terms of depth and mass resolution and sensitivity compared to conventional RBS based on planar Si detectors. The start timing-signal is produced by the secondary electrons emitted from a thin C foil when traversed by a backscattered ion; the electrons are deflected in an electrostatic mirror towards a Micro-channel plate (MCP) assembly which provides a fast timing response. The stop signal is obtained directly from a second MCP assem…
A precision measurement of charm dimuon production in neutrino interactions from the NOMAD experiment
2013
We present our new measurement of the cross-section for charm dimuon production in neutrino iron interactions based upon the full statistics collected by the NOMAD experiment. After background subtraction we observe 15 344 charm dimuon events, providing the largest sample currently available. The analysis exploits the large inclusive charged current sample - about 9 x 10(6) events after all analysis cuts - and the high resolution NOMAD detector to constrain the total systematic uncertainty on the ratio of charm dimuon to inclusive Charged Current (CC) cross-sections to similar to 2%. We also perform a fit to the NOMAD data to extract the charm production parameters and the strange quark sea…
First microscopic evaluation of spin-dependent WIMP-nucleus scattering off 183W
2021
We perform the first consistent calculation of elastic-scattering and inelastic-scattering structure functions for spin-dependent WIMP-nucleus scattering for 183W in a microscopic nuclear-theory framework. The nuclear structure calculations are performed in the microscopic interacting boson-fermion model (IBFM-2). Our results show that while 183W is very insensitive to spin-dependent elastic scattering, the structure function for inelastic scattering is quite sizable at small momentum transfers. Moreover, to our knowledge 183W provides the first studied case where inelastic scattering can compete with elastic scattering as the primary detection signal. peerReviewed
Measurements of forward proton production with incident protons and charged pions on nuclear targets at the CERN Proton Synchroton
2010
Measurements of the double-differential proton production cross-section d(2 sigma)/dpd Omega in the range of momentum 0.5 GeV/c <= p < 8.0 GeV/c and angle 0.05 rad <= theta < 0.25 rad in collisions of charged pions and protons on beryllium, carbon, aluminium, copper, tin, tantalum, and lead are presented. The data were taken with the large acceptance HARP detector in the T9 beam line of the CERN Proton Synchrotron. Incident particles were identified by an elaborate system of beam detectors and impinged on a target of 5% of a nuclear interaction length. The tracking and identification of the produced particles was performed using the forward spectrometer of the HARP experiment. Results are o…
Ion source and low energy beam transport prototyping for a single-ended heavy ion ToF-ERDA facility
2023
We present the status of the ion source and low energy beam transport prototyping activities for a heavy ion time-of-flight elastic recoil detection analysis (ToF-ERDA) equipment, designed to accelerate a flux of 1–10 particle nano-Ampere of 40Ar6-12+ ions to 3–6 MeV energy for depth profiling of light elements. The prototype injector consists of a novel permanent magnet electron cyclotron resonance ion source CUBE-ECRIS with a minimum-B quadrupole field topology, and a 90° permanent magnet dipole with adjustable field strength for charge state selection. We report experimentally measured argon beam currents as a function of the applied microwave power and ion source potential to demonstrat…
Beam-normal single spin asymmetry in elastic electron scattering off 28Si and 90Zr
2020
We report on a new measurement of the beam-normal single spin asymmetry $A_{\mathrm{n}}$ in the elastic scattering of 570 MeV transversely polarized electrons off $^{28}$Si and $^{90}$Zr at $Q^{2}=0.04\, \mathrm{GeV}^2/c^2$. The studied kinematics allow for a comprehensive comparison with former results on $^{12}$C. No significant mass dependence of the beam-normal single spin asymmetry is observed in the mass regime from $^{12}$C to $^{90}$Zr.