Search results for "Elastic"

showing 10 items of 2162 documents

In vivo achilles tendon loading' during jumping in humans

1995

Elastic behaviour of the human tendomuscular system during jumping was investigated by determination of the in vivo Achilles tendon force. A buckle-type transducer was implanted under local anaesthesia around the right Achilles tendon of an adult subject. After calibration, the Achilles tendon force was recorded together with the triceps surae muscle electromyogram activity and high speed filming and ground reaction force during: a maximal vertical jump from a squat position, a maximal vertical jump from an erect standing position with a preliminary counter-movement, and repetitive submaximal hopping on the spot. Jumping heights were 33, 40 and 7 cm in the squat, the counter movement, and t…

AdultMalemusculoskeletal diseasesMaterials sciencePhysiologyPhysical ExertionSquatmedicine.disease_causeAchilles TendonVertical jumpJumpingTriceps surae musclePhysiology (medical)medicineHumansOrthopedics and Sports MedicineGround reaction forceMuscle SkeletalAchilles tendonElectromyographyWork (physics)Public Health Environmental and Occupational HealthGeneral MedicineAnatomymusculoskeletal systemElasticityBiomechanical PhenomenaTendonmedicine.anatomical_structureEuropean Journal of Applied Physiology and Occupational Physiology
researchProduct

Mechanical Properties of Human Patellar Tendon at the Hierarchical levels of Tendon and Fibril

2012

Tendons are strong hierarchical structures, but how tensile forces are transmitted between different levels remains incompletely understood. Collagen fibrils are thought to be primary determinants of whole tendon properties, and therefore we hypothesized that the whole human patellar tendon and its distinct collagen fibrils would display similar mechanical properties. Human patellar tendons ( n = 5) were mechanically tested in vivo by ultrasonography. Biopsies were obtained from each tendon, and individual collagen fibrils were dissected and tested mechanically by atomic force microscopy. The Young's modulus was 2.0 ± 0.5 GPa, and the toe region reached 3.3 ± 1.9% strain in whole patellar …

AdultMalemusculoskeletal diseasesMaterials sciencePhysiologymacromolecular substancesFibrilMicroscopy Atomic ForceCollagen fibrilPatellar LigamentPhysiology (medical)Elastic ModulusUltimate tensile strengthMicroscopymedicineHumansAtomic force microscopyta1182ta3141Anatomymusculoskeletal systemPatellar tendonTendonBiomechanical Phenomenamedicine.anatomical_structureCollagenStress Mechanical
researchProduct

Interaction between pre-landing activities and stiffness regulation of the knee joint musculoskeletal system in the drop jump: implications to perfor…

2002

The purpose of the present study was to investigate the interaction between the pre-landing activities and the stiffness regulation of the knee joint musculoskeletal system and the takeoff speed during a drop jump (DJ). Nine healthy male subjects performed a DJ test from the height of 50 cm. The surface electromyographic (EMG) activity of the vastus lateralis (VL) muscle was recorded to evaluate both the pre-landing and post-landing muscle activation levels. Simultaneous recording of the jumping motion and ground reaction force was performed by a high-speed video camera (100 frames x s(-1)), and a force platform was employed to allow joint moment analysis. Joint stiffness was calculated by …

AdultMalemusculoskeletal diseasesmedicine.medical_specialtyKnee JointIsometric exerciseMotor ActivityKnee Jointmedicine.disease_causeStretch shortening cycleJumpingPhysical medicine and rehabilitationPhysiology (medical)medicineHumansOrthopedics and Sports MedicineGround reaction forceMuscle SkeletalPhysicsViscosityPublic Health Environmental and Occupational HealthBody movementGeneral MedicineAnatomymusculoskeletal systemElasticityBiomechanical Phenomenamedicine.anatomical_structureJoint stiffnessAnklemedicine.symptomSportsEuropean Journal of Applied Physiology
researchProduct

In vivo mechanical response of human Achilles tendon to a single bout of hopping exercise

2010

SUMMARY Stiffness of the human Achilles tendon (AT) was determined in vivo before and after a single bout of hopping exercise. It was hypothesized, based on published data using in vitro specimens, that a reduction in AT stiffness may occur after just 1000 loading cycles at physiological stress levels. Ten healthy subjects performed two-legged hopping exercise consisting of 1150–2600 high impacts. Tendon stiffness was determined in several isometric ramp contractions [20%, 40%, 60%, 80% and 100% maximum voluntary contraction (MVC)] during which tendon elongation was measured using ultrasonography and two cameras. Tendon force was calculated by dividing measured ankle torque by magnetic reso…

AdultMalemusculoskeletal diseasesmedicine.medical_specialtyPhysiologyMovementIsometric exerciseAquatic ScienceAchilles TendonYoung AdultIn vivoInternal medicinemedicineAnimalsHumansMuscle SkeletalExerciseMolecular BiologyEcology Evolution Behavior and SystematicsPhysiological stressAchilles tendonbusiness.industryBiomechanicsStiffnessAnatomymusculoskeletal systemElasticityBiomechanical PhenomenaTendonmedicine.anatomical_structureInsect ScienceCardiologyFemaleAnimal Science and ZoologyStress Mechanicalmedicine.symptombusinessMuscle ContractionMuscle contraction
researchProduct

Intensity- and muscle-specific fascicle behavior during human drop jumps.

2006

The present study was designed to examine fascicle-tendon interaction in the synergistic medial gastrocnemius (MG) and soleus (Sol) muscles during drop jumps (DJ) performed from different drop heights (DH). Eight subjects performed unilateral DJ with maximal rebounds on a sledge apparatus from different DH. During the exercises, fascicle lengths (using ultrasonography) and electromyographic activities were recorded. The results showed that the fascicles of the MG and Sol muscles behaved differently during the contact phase, but the whole muscle-tendon unit and its tendinous tissue lengthened before shortening in both muscles. The Sol fascicles also lengthened before shortening during the g…

AdultPhysiologyMovementMuscle Fibers SkeletalElectromyographyStretch shortening cycleGround contactTendonsPhysiology (medical)medicineHumansMuscle SkeletalExerciseUltrasonographymedicine.diagnostic_testbusiness.industryChemistryElectromyographyDrop (liquid)AnatomyFascicleElasticityBiomechanical Phenomenamedicine.anatomical_structureBiarticular muscleLength changeUltrasonographybusinessMuscle ContractionJournal of applied physiology (Bethesda, Md. : 1985)
researchProduct

Characterisation of indeterminate focal breast lesions on grey-scale ultrasound: role of ultrasound elastography.

2011

PURPOSE: This study was undertaken to evaluate the role of ultrasound (US) elastography in characterising focal breast lesions classified as indeterminate on B-mode US. MATERIALS AND METHODS: Eighty-four focal breast lesions, 64 benign and 20 malignant (mean diameter, 15.1 mm), detected but not characterised on B-mode US in 72 women, Breast Imaging Reporting and Data System (BI-RADS) US category 3 (n=56) or category 4 (n=28), were studied with US elastography and classified in consensus by two radiologists according to a five-point colour scale. Sensitivity, specificity and positive and negative predictive values (PPV and NPV) of US elastography compared with conventional US were calculated…

Adultmedicine.medical_specialtyBreast NeoplasmsGrey scaleSensitivity and SpecificityDiagnosis DifferentialElasticity Imaging TechniquesPredictive Value of TestsmedicineUltrasound elastographyHumansRadiology Nuclear Medicine and imagingProspective StudiesNeuroradiologyAgedAged 80 and overmedicine.diagnostic_testbusiness.industryUltrasoundInterventional radiologyGeneral MedicineMiddle AgedElasticity Imaging TechniquesFemaleRadiologyElastographyUltrasonography MammaryBreast Ultrasound elastography Breast neoplasmsbusinessIndeterminateSettore MED/36 - Diagnostica Per Immagini E RadioterapiaAlgorithms
researchProduct

A ballistometer for the study of the plasto-elastic properties of skin.

1977

The ballistrometer is based on the "drop impact" of a body onto a stationary surface. A collision in one dimension is provoked by allowing a bard body to drop from a given height onto the skin surface to be tested. After the collision, the impacting body undergoes a variable number of rebounds decreasing in amplitude. By measuring the height of the rebounds, the amount of energy returned by the tissue is calculated in terms of coefficient of restitution e. The equipment, consisting of a hammer unit, a feeder-amplifier, and a plotter, is described. Ballistometry has been carried out on skin areas of 46 normal subjects ranging in age from 8 to 80 years, as well as on pathologic and cadaveric …

Adultmedicine.medical_specialtyMaterials scienceAdolescentEpidermal hyperplasiaDermatologyBiochemistrySkin DiseasesSkin Physiological PhenomenaSkin surfacemedicineSKIN REGIONSHumansChildMolecular BiologyAgedSkinintegumentary systemDrop (liquid)Age FactorsCell BiologyMiddle AgedElasticitySurgeryDrop impactCoefficient of restitutionStress MechanicalVariable numberCadaveric spasmBiomedical engineeringThe Journal of investigative dermatology
researchProduct

Combined effect of elastic energy and myoelectrical potentiation during stretch-shortening cycle exercise.

1982

In addition to the utilization of muscle's elastic energy enhancement of performance in exercise involving stretch-shortening cycle might be also due to simultaneous increase of myoelectrical activity. This hypothesis was tested by examining three athletes during jumping exercise on force-platform. Vertical jumps were performed with and without preliminary counter-movement, and the jumps were called counter-movement jump (CMJ) and squatting jump (SJ), respectively. In both conditions several jumps were performed also with extra loads on the shoulders (15–220% of b. wt.). Additional droppingjumps (DJ) were executed from different heights (20–100 cm). During jumping exercise myoelectrical act…

Adultmedicine.medical_specialtyPhysiologyPhysical ExertionAction PotentialsElectromyographyConcentricmedicine.disease_causeStretch shortening cycleJumpingmedicineEccentricHumansmedicine.diagnostic_testElectromyographyMusclesWork (physics)ElasticityElectrophysiologyReflexPhysical therapymedicine.symptomMathematicsMuscle contractionBiomedical engineeringMuscle ContractionActa physiologica Scandinavica
researchProduct

Short-term changes in the series elastic component after an acute eccentric exercise of the elbow flexors

2001

We have studied the effect of a unique eccentric exercise session on the series elastic component (SEC) properties of human elbow flexors. Ten active females performed five sets of ten maximal eccentric contractions on an isokinetic ergometer. Maximal isometric (MVC) torque, and the corresponding myoelectrical activity (RMS) of the biceps brachii and the triceps brachii muscles were recorded before, immediately after, 48 h after, and 1 week after the exercise session. SEC compliance was also measured, using the in situ quick-release technique. Maximal eccentric torque declined significantly among the five sets of the exercise session (P < 0.01). The exercise session induced a significant de…

Adultmedicine.medical_specialtySports medicinePhysiologyElbowIsometric exerciseElectromyographyBicepsPhysical medicine and rehabilitationIsometric ContractionPhysiology (medical)Elbow JointmedicineHumansEccentricOrthopedics and Sports MedicineExercise physiologyExercisemedicine.diagnostic_testElectromyographybusiness.industryPublic Health Environmental and Occupational HealthGeneral MedicineElasticitymedicine.anatomical_structureTorquePhysical therapyFemalemedicine.symptombusinessMuscle contractionEuropean Journal of Applied Physiology
researchProduct

Acute and prolonged reduction in joint stiffness in humans after exhausting stretch-shortening cycle exercise.

2002

The purpose of the present study was to examine the acute and long-term fatigue effects of exhausting stretch-shortening cycle (SSC) exercise on the stiffness of ankle and knee joints. Five subjects were fatigued on a sledge apparatus by 100 maximal rebound jumps followed by continuous submaximal jumping until complete exhaustion. Neuromuscular fatigue ef- fects were examined in submaximal hopping (HOP) and in maximal drop jumps (DJ) from 35 (DJ35) and 55 cm (DJ55) heights on a force plate. Additional force and reflex measurements were made using an ankle ergom- eter. Jumping tests and ankle ergometer tests were car- ried out before, immediately after, 2 h (2H), 2 days and 7 days (7D) after…

Adultmedicine.medical_specialtyTime FactorsKnee JointPhysical exerciseElectromyographyKnee Jointmedicine.disease_causeStretch shortening cycleJumpingPhysiology (medical)Internal medicineMedicineHumansOrthopedics and Sports MedicineLactic AcidCreatine Kinasemedicine.diagnostic_testbusiness.industryElectromyographyPublic Health Environmental and Occupational HealthGeneral MedicineRecovery of FunctionElasticitySurgeryBicyclingBiomechanical Phenomenamedicine.anatomical_structureJoint stiffnessMuscle FatigueReflexCardiologyPhysical EnduranceAnklemedicine.symptombusinessAnkle JointEuropean journal of applied physiology
researchProduct