Search results for "Electrode"

showing 10 items of 950 documents

Precursor Polymers for the Carbon Coating of Au@ZnO Multipods for Application as Active Material in Lithium-Ion Batteries

2014

The synthesis of statistical and block copolymers based on polyacrylonitrile, as a source for carbonaceous materials, and thiol-containing repeating units as inorganic nanoparticle anchoring groups is reported. These polymers are used to coat Au@ZnO multipod heteroparticles with polymer brushes. IR spectroscopy and transmission electron microscopy prove the successful binding of the polymer onto the inorganic nanostructures. Thermogravimetric analysis is applied to compare the binding ability of the block and statistical copolymers. Subsequently, the polymer coating is transformed into a carbonaceous (partially graphitic) coating by pyrolysis. The obtained carbon coating is characterized by…

Thermogravimetric analysisMaterials sciencePolymers and PlasticsPolymersInorganic chemistryAcrylic ResinsMetal NanoparticlesInfrared spectroscopyNanoparticleLithiumengineering.materialchemistry.chemical_compoundsymbols.namesakeElectric Power SuppliesMicroscopy Electron TransmissionCoatingMaterials ChemistryElectrodesIonschemistry.chemical_classificationOrganic ChemistryPolyacrylonitrileSpectrometry X-Ray EmissionElectrochemical TechniquesPolymerCarbonchemistryengineeringsymbolsGoldZinc OxideRaman spectroscopyPyrolysisMacromolecular Rapid Communications
researchProduct

Cs0.86(NH41.14SO4Te(OH)6 in porous anodic alumina for micro fuel cell applications.

2011

Abstract Cs0.86(NH4)1.14SO4Te(OH)6 supported by anodic alumina membranes (AAMs) has been characterized for the first time in H2/O2 fuel cell. The fabricated membrane electrode assemblies are able to produce peak power densities in the range 15–30 mW cm−2 under mild conditions (room temperature, low humidity and low Pt loading) and show an increased durability with cycling with respect to previous results obtained with AAM-based fuel cell. The physico-chemical characterization of the electrolytes has been carried out through X-ray diffractometry, scanning electron microscopy and micro-raman analysis. An estimation of the composite membranes conductance under fuel cell operation has been carr…

Thin film fuel cellScanning electron microscopeChemistryGeneral Chemical EngineeringInorganic chemistryConductanceElectrolytePorous alumina fuel cellCesium ammonium sulphate tellurateAnodeMembraneSettore ING-IND/23 - Chimica Fisica ApplicataChemical engineeringElectrodeComposite proton conductors Porous alumina fuel cell Thin film fuel cell Cesium ammonium sulphate tellurateElectrochemistryComposite proton conductorThin filmPorosity
researchProduct

Novel Ni(II) Mixed Ligand Complex Modified Electrode: Catalytic Effect on Anodic Oxidation of Phenol

2004

Cyclic voltammetry, using graphite paste electrode (GPE) and chemically modified GPE with Ni(II) mixed ligand complex (MGPE), is described for sensing and detoxification of phenol. A novel mixed ligand complex of nickel with 1,4,8,11-tetraaza cyclotetradecane (cyclam) and thiocyanate in the molar ratio of 1 : 2 : 5 is synthesized and characterized by spectroscopic and electrochemical studies. The Ni(II)-cyclam-thiocyanate complex behaves as a fast electron-transfer mediator, as nickel ions exist in higher oxidation state of Ni(III) on applying a potential of 1.25 V (vs. Ag/AgCl), which catalyses the oxidation of the target species. The mixed ligand complex, when incorporated in the graphite…

ThiocyanateInorganic chemistrychemistry.chemical_elementElectrochemistryAnalytical Chemistrychemistry.chemical_compoundNickelchemistryOxidation stateCyclamElectrochemistryCyclotetradecaneCyclic voltammetryChemically modified electrodeElectroanalysis
researchProduct

A simple method for preoperative assessment of the best fitting electrode length in single lead VDD pacing.

1996

For single lead VDD pacing, electrodes with various distances between the lead tip and the floating atrial dipole (AV distance) are available. Using different AV distances allows positioning of the atrial dipole in the mid- to high right atrium, regardless of the size of the right heart. In this position, reliable atrial sensing and rejection of ventricular far-field potentials can be expected. A simple test for the preoperative assessment of the best fitting AV distance in the individual patient was tested. We studied 24 consecutive patients prior to implantation of a VDD pacemaker. With the patient in supine position, a test electrode with an AV distance of 13 cm was taped onto the thorax…

ThoraxAdultMalePacemaker ArtificialSupine positionmedicineFluoroscopyHumansHeart AtriaLead (electronics)AgedAged 80 and overmedicine.diagnostic_testbusiness.industryGeneral MedicineMiddle AgedElectrodes ImplantedDipoleSingle leadFluoroscopyElectrodeVdd pacingFemaleCardiology and Cardiovascular MedicinebusinessNuclear medicinePacing and clinical electrophysiology : PACE
researchProduct

Potential Application of Voltammetry of Microparticles for Dating Porcine Blood-based Binding Media used in Taiwanese Architectural Polychromies

2012

A method for dating Hemoglobine-containing archaeological samples using the voltammetry of microparticles is described. This is based on the record of the voltammetric response of such materials attached to paraffin-impregnated graphite electrodes in contact with aqueous acetate buffer. Signals attributable to the Fe(III)/Fe(II) iron couple and their catalytic enhancement in the presence of H(2)O(2) can be correlated, via first-order reaction kinetics, with the time of aging of the samples. The method has been applied to the study and dating of the polychromed architectural decoration of different parts of the architectural complex of the Longshan Temple in Lukang (18(th)  century, Taiwan).

Time FactorsAqueous solutionSwineChemistryOrganic ChemistryTaiwanAnalytical chemistryElectrochemical TechniquesHydrogen PeroxideGeneral ChemistryFerric CompoundsBiochemistryCatalysisGas Chromatography-Mass SpectrometryCatalysisHemoglobinsAnimalsGraphiteFerrous CompoundsElectrodesVoltammetryPorcine bloodGraphite electrodeNuclear chemistryChemistry - An Asian Journal
researchProduct

Hippocampal theta (3-8 Hz) activity during classical eyeblink conditioning in rabbits

2007

In 1978, Berry and Thompson showed that the amount of theta (3–8 Hz) activity in the spontaneous hippocampal EEG predicted learning rate in subsequent eyeblink conditioning in rabbits. More recently, the absence of theta activity during the training trial has been shown to have a detrimental effect on learning rate. Here, we aimed to further explore the relationship between theta activity and classical eyeblink conditioning by determining how the relative power of hippocampal theta activity [theta/(theta + delta) ratio] changes during both unpaired control and paired training phases. We found that animals with a higher hippocampal theta ratio immediately before conditioning learned faster a…

Time FactorsCognitive NeuroscienceCentral nervous systemeducationHippocampusExperimental and Cognitive PsychologyHippocampal formationElectroencephalographyHippocampusBehavioral Neurosciencemedicinedelay ehdollistaminenAnimalsLearninghippokampusEEGTheta Rhythmmedicine.diagnostic_testBehavior AnimalClassical conditioningConditioning EyelidClassical conditioningElectrodes ImplantedElectrophysiologymedicine.anatomical_structureEyeblink conditioningConditioningFemaleRabbitsPsychologyklassinen ehdollistaminenNeuroscienceDelay conditioning
researchProduct

Concurrent fast and slow synchronized efferent phrenic activities in time and frequency domain.

1990

Abstract In urethane-anesthetized or decerebrated vagotomized rabbits efferent multifiber activity of the phrenic nerve was investigated for synchronized activities both in time and frequency domains. When respiratory drive was steadily increased by either an elevation of end-tidal CO2 concentration or i.v. administration of 4-aminopyridine, medium-frequency oscillations (MFO) first increased, then decreased and finally became absent. The power of high-frequency oscillations (HFO) steadily rose with increasing respiratory drive. In contrast to HFO which revealed a unimodal spectral peak of mostly small bandwidth, the MFO spectrum in most cases consisted of a broad complex. This complex in s…

Time FactorsEfferentEfferent PathwaysNerve FibersCo2 concentrationmedicineRecording electrodeTidal VolumeAnimals4-AminopyridineMolecular BiologyBroad complexPhrenic nerveChemistryGeneral NeuroscienceRespirationSpectrum Analysis4-AminopyridineRats Inbred StrainsCarbon DioxideRatsPhrenic NerveControl of respirationFrequency domainBiophysicsNeurology (clinical)RabbitsDevelopmental Biologymedicine.drugBrain research
researchProduct

Metodo di realizzazione di un elettrodo ad elevata densità energetica ed elettrodo ottenibile con tale metodo

2010

Tin Tin Alloys Nanostructures Template electrodeposition Anode Lithium ion batterySettore ING-IND/23 - Chimica Fisica Applicata
researchProduct

Electrosynthesis of Sn-Co nanowires in alumina membranes

2010

A fabrication process of amorphous nanowires of Sn-Co alloys, based on electrodeposition into anodic alumina membranes, is described. It is shown that nanowires of tin-cobalt alloys with different compositions can be produced by varying electrodeposition time and concentration ratio of salts dissolved into the electrolytic bath. Importance of the chelating agent to produce amorphous Sn-Co alloys has also been addressed. Electrodepositions were carried out potentiostatically at -1 V versus Saturated Calomel Electrode and 60 degrees C for times ranging from 10 to 90 minutes; the atomic fraction of Co2+ in the aqueous electrolyte (Co2+/(Co2+ + Sn2+)) was varied from 0.33 to 0.67. Nanowires asp…

Tin–Cobalt Alloys Template Synthesis Alumina Membranes Li-Ion Batteries Tin AnodeMaterials scienceScanning electron microscopeAlloytechnology industry and agricultureBiomedical EngineeringNanowireAnalytical chemistryEnergy-dispersive X-ray spectroscopyBioengineeringGeneral ChemistryElectrolyteengineering.materialequipment and suppliesCondensed Matter PhysicsConcentration ratioAmorphous solidSettore ING-IND/23 - Chimica Fisica ApplicataSaturated calomel electrodeengineeringGeneral Materials Science
researchProduct

Cavitation corrosion and repassivation kinetics of titanium in a heavy brine LiBr solution evaluated by using electrochemical techniques and Confocal…

2011

The cavitation corrosion behaviour of commercially pure Grade 2 titanium in a 992 g/l LiBr solution has been investigated at 25 °C using an ultrasound device. Cavitation was found to have more influence on the anodic branch than on the cathodic branch, shifting the corrosion potential, Ecorr, and the OCP value towards more negative potentials, and increasing the corrosion current density, icorr, by six times. The repassivation kinetics of Grade 2 titanium have also been studied in the 992 g/l LiBr solution, at 25 °C and various applied potentials, using cavitation to damage the electrode surface. The repassivation kinetics have been analysed in terms of the current density flowing from the …

TitaniumCavitationMaterials scienceGeneral Chemical EngineeringConfocal Laser Scanning MicroscopyKineticsMeasurementsAnalytical chemistrychemistry.chemical_elementTitaniPotentiostaticElectrochemistryINGENIERIA QUIMICACathodic protectionCorrosionRepassivationElectroquímicachemistryCavitationElectrodeElectrochemistryCurrent densityTitanium
researchProduct