Search results for "Electrospray Ionization"
showing 10 items of 275 documents
Development of a novel methodology for determination of dialkyl phosphates in human urine using liquid chromatography-tandem mass spectrometry
2019
Abstract In this study a fast and sensitive method was developed for the quantitative determination of six dialkyl phosphates (DAPs) in human urine using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The proposed methodology was based on liquid-liquid extraction (LLE) with diethyl ether and ethyl acetate using MgSO4 and NaCl, followed by liquid chromatography and mass spectrometry detection in the selected reaction mode (SRM) with negative electrospray ionization (ESI-). Detection settings were optimized by design of experiments (DoE). Dibutyl phosphate (DBP) was used as internal standard. Several criteria established in the SANTE/11813/2017 guidance document for pesticide resi…
Detection of gamma-hydroxybutyrate in hair: Validation of GC–MS and LC–MS/MS methods and application to a real case
2012
A gas chromatography-mass spectrometry (GC-MS) and a liquid chromatography tandem mass spectrometry (LC-MS/MS) method were validated for quantifying endogenous and exogenous hair concentrations of gamma-hydroxybutyrate (GHB). The GC-MS method is based on overnight extraction of 25 mg hair in NaOH at 56 °C, liquid/liquid extraction in ethylacetate and trimethylsylil derivatization; analysis is by electron ionization and single ion monitoring of three ions. The LC-MS/MS method entails a rapid digestion of 25 mg hair with NaOH at 75 °C for 40 min, liquid/liquid extraction in ethylacetate and reconstitution of the extract in the LC mobile phase; negative ion electrospray ionization and multiple…
Identification of organic hydroperoxides and hydroperoxy acids in secondary organic aerosol formed during the ozonolysis of different monoterpenes an…
2009
On-line ion trap mass spectrometry (ITMS) enables the real-time characterization of reaction products of secondary organic aerosol (SOA). The analysis was conducted by directly introducing the aerosol particles into the ion source. Positive-ion chemical ionization at atmospheric pressure (APCI(+)) ITMS was used for the characterization of constituents of biogenic SOA produced in reaction-chamber experiments. APCI in the positive-ion mode usually enables the detection of [M+H](+) ions of the individual SOA components. In this paper the identification of organic peroxides from biogenic volatile organic compounds (VOCs) by on-line APCI-ITMS is presented. Organic peroxides containing a hydroper…
Characterization of oligomeric compounds in secondary organic aerosol using liquid chromatography coupled to electrospray ionization Fourier transfor…
2009
The components of secondary organic aerosols (SOAs) generated from the gas-phase ozonolysis of two C(10)H(16)-terpenes (alpha-pinene; sabinene) and a cyclic C(6)H(10) alkene (cyclohexene) were characterized by the use of a Fourier transform ion cyclotron mass spectrometer equipped with an electrospray ionization source operated in the negative ion mode. Reversed-phase high-performance liquid chromatography was used to achieve chromatographic separation of highly oxidized organic compounds. In addition to the well-known group of low molecular weight oxidation products (monomers; e.g. dicarboxylic acids), higher molecular weight compounds (dimers) were also detected and their exact elemental …
Surfactant self-assembling in gas phase: electrospray ionization- and matrix-assisted laser desorption/ionization-mass spectrometry of singly charged…
2005
The self-assembling of sodium bis (2-ethylhexyl) sulfosuccinate (AOT) in gas phase has been investigated by electrospray ionization- and matrix-assisted laser desorption/ionization mass spectrometry. Large surfactant clusters with an aggregation number close to that found in apolar media have been observed either as positive or negative ions. Moreover, the marked predominance of singly charged species as well as preliminary theoretical calculations strongly suggest an aggregate structure characterized by an internal hydrophilic core hosting the extra charge surrounded by an apolar shell constituted by the surfactant alkyl chains. This structure is similar to that of the more familiar revers…
Classification of vegetable oils according to their botanical origin using amino acid profiles established by direct infusion mass spectrometry.
2007
Amino acid profiles, established by direct infusion mass spectrometry, have been used to classify vegetable oils according to their botanical origin. The proteins present in hazelnut, sunflower, corn, soybean, olive, avocado, peanut and grapeseed oils were precipitated with acetone, and the residue was hydrolyzed in acid medium, diluted in a hydrochloric acid/ethanol mixture, and infused into the mass spectrometer. The spectra of the hydrolyzed protein extracts showed [M+H]+ ions of the following amino acids: glycine, alanine, serine, proline, valine, threonine, cysteine, isoleucine + leucine, aspartic acid, lysine, glutamic acid, methionine, histidine, phenylalanine, arginine and tyrosine.…
Supramolecular Aggregates in Vacuum: Positively Mono-Charged Sodium Alkanesulfonate Clusters
2010
The formation and structural features of positively mono-charged aggregates of sodium bis(2-ethylhexyl) sulfosuccinate (AOT) and sodium methane—(MetS), butane—(ButS) and octane—(OctS) sulfonate molecules in the gas phase have been investigated by electrospray ionization mass spectrometry, energy-resolved mass spectrometry and density functional theory (DFT) calculations. The experimental results show that the center-of-mass collision energy required to dissociate 50% of these mono-charged aggregates scantly depends on the length of the alkyl chain as well as on the aggregation number. This, together with the large predominance of mono-charged species in the mass spectra, was rationalized i…
Ammonium ion mediated resorcarene capsules: ESI-FTICRMS study on gas-phase structure and ammonium ion affinity of tetraethyl resorcarene and its per-…
2003
AbstractThe ammonium ion binding affinities of tetraethyl resorcarene (1) and its per-methylated derivative (2) were studied by electrospray ionization Fourier transform ion cyclotron resonance (ESI-FTICR) mass spectrometry. Ten different ammonium ions were tested as guests for the resorcarenes. A strong tendency for complex formation was observed with all ammonium ions of size and charge distribution suitable for noncovalent interactions with the cavities of the resorcarene hosts 1 and 2. Although differences in ammonium ion affinities were observed between 1 and 2 due to the dissimilar conformations, the overall tendency was that increase in the degree of substitution and the length of ca…
Extraction and Sample Preparation
2015
As everyone knows, the role played by extraction and sample preparation in the analytical sciences cannot be overemphasized. Despite tremendous advances in chromatography, detection, and other aspects of analysis, extraction and sample preparation remain a preanalysis ritual of critical importance. It has been estimated that around 50% to 70% possibly even more of the time and effort that goes into an analytical process comprises extraction and sample preparation. Sample preparation procedure can vary in the degree of selectivity, speed, and convenience, depending on the approach and conditions used, as well as on the geometric configurations of the extraction phase and conditions. Proper d…
Validation of a confirmatory method for the determination of macrolides in liver and kidney animal tissues in accordance with the European Union regu…
2006
Abstract This study proposes a simple multiresidue liquid chromatography–diode array detector (LC–DAD) method capable of determining seven macrolide antibiotics in samples of liver and kidney animals at concentrations lower than those allowed by current legislation. Samples were prepared by homogenizing the tissue with EDTA–McIlvaine's buffer and extracted with an Oasis HLB cartridge. The consumption of organic solvent during extraction was minimum. The analytes were detected by LC–DAD and also by liquid chromatography–mass spectrometry with electrospray ionization (LC–(ESI)MS). The method was specific, stable and robust enough for the required purposes. The DAD method was validated in acco…